ABAP Select data from SAP table J_7LKCV2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP J_7LKCV2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to J_7LKCV2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the J_7LKCV2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_J_7LKCV2 TYPE STANDARD TABLE OF J_7LKCV2,
      WA_J_7LKCV2 TYPE J_7LKCV2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <J_7LKCV2> TYPE J_7LKCV2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_J_7LKCV2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM J_7LKCV2
  INTO TABLE IT_J_7LKCV2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM J_7LKCV2
*  INTO TABLE @DATA(IT_J_7LKCV22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_J_7LKCV2 INDEX 1 INTO DATA(WA_J_7LKCV22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_J_7LKCV2 ASSIGNING <J_7LKCV2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<J_7LKCV2>-MANDT = 1.
<J_7LKCV2>-VRPNR = 1.
<J_7LKCV2>-VRPTX = 1.
<J_7LKCV2>-VVARIANTE = 1.
<J_7LKCV2>-BUKRS = 1.
ENDLOOP.

LOOP AT IT_J_7LKCV2 INTO WA_J_7LKCV2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_J_7LKCV2-LAND1, sy-vline,
WA_J_7LKCV2-ENTNR, sy-vline,
WA_J_7LKCV2-VKORG, sy-vline,
WA_J_7LKCV2-VTWEG, sy-vline,
WA_J_7LKCV2-SPART, sy-vline,
WA_J_7LKCV2-WERKS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_J_7LKCV2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_J_7LKCV2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_J_7LKCV2 INTO WA_J_7LKCV2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field VRPNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_J_7LKCV2-VRPNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_7LKCV2-VRPNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ENTNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_J_7LKCV2-ENTNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_7LKCV2-ENTNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_J_7LKCV2-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_7LKCV2-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_J_7LKCV2-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_7LKCV2-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HKUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_J_7LKCV2-HKUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_7LKCV2-HKUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_J_7LKCV2-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_7LKCV2-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_J_7LKCV2-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_7LKCV2-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINA CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_J_7LKCV2-MEINA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_7LKCV2-MEINA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field KMEIN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_J_7LKCV2-KMEIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_7LKCV2-KMEIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GEWEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_J_7LKCV2-GEWEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_7LKCV2-GEWEI.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_J_7LKCV2_STR,
MANDT TYPE STRING,
VRPNR TYPE STRING,
VRPTX TYPE STRING,
VVARIANTE TYPE STRING,
BUKRS TYPE STRING,
LAND1 TYPE STRING,
ENTNR TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
WERKS TYPE STRING,
LLAND TYPE STRING,
KUMRK TYPE STRING,
KUNNR TYPE STRING,
EKORG TYPE STRING,
LIMRK TYPE STRING,
LIFNR TYPE STRING,
MTART TYPE STRING,
GRUPPE TYPE STRING,
MATKL TYPE STRING,
PRDHA TYPE STRING,
MBRSH TYPE STRING,
GSBER TYPE STRING,
HKUNNR TYPE STRING,
HVKORG TYPE STRING,
HVTWEG TYPE STRING,
HSPART TYPE STRING,
HITYP TYPE STRING,
HISTUNR TYPE STRING,
MATNR TYPE STRING,
VARIANTE TYPE STRING,
POSAR TYPE STRING,
POSAR2 TYPE STRING,
KOART TYPE STRING,
KOKEY TYPE STRING,
KZPRAD TYPE STRING,
SPLIT TYPE STRING,
DATAB TYPE STRING,
DATBI TYPE STRING,
PLVRS TYPE STRING,
SOKOA TYPE STRING,
PLTYP TYPE STRING,
NETWR TYPE STRING,
PGAAWR TYPE STRING,
WAERK TYPE STRING,
NETWE TYPE STRING,
WAERE TYPE STRING,
MENGE TYPE STRING,
MEINS TYPE STRING,
MENGP TYPE STRING,
FKIMG TYPE STRING,
MEINA TYPE STRING,
FKIMP TYPE STRING,
VFLKL TYPE STRING,
VFLST TYPE STRING,
KMEIN TYPE STRING,
STOFE TYPE STRING,
STGEW TYPE STRING,
GEWEI TYPE STRING,
VPEBENE TYPE STRING,
VPARTG TYPE STRING,
VPARTS TYPE STRING,
VRPKT TYPE STRING,
INFOK TYPE STRING,
FUELLG TYPE STRING,
HDLST TYPE STRING,END OF T_EKKO_STR. DATA: WA_J_7LKCV2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_J_7LKCV2_STR-MANDT sy-vline
WA_J_7LKCV2_STR-VRPNR sy-vline
WA_J_7LKCV2_STR-VRPTX sy-vline
WA_J_7LKCV2_STR-VVARIANTE sy-vline
WA_J_7LKCV2_STR-BUKRS sy-vline
WA_J_7LKCV2_STR-LAND1 sy-vline
WA_J_7LKCV2_STR-ENTNR sy-vline
WA_J_7LKCV2_STR-VKORG sy-vline
WA_J_7LKCV2_STR-VTWEG sy-vline
WA_J_7LKCV2_STR-SPART sy-vline
WA_J_7LKCV2_STR-WERKS sy-vline
WA_J_7LKCV2_STR-LLAND sy-vline
WA_J_7LKCV2_STR-KUMRK sy-vline
WA_J_7LKCV2_STR-KUNNR sy-vline
WA_J_7LKCV2_STR-EKORG sy-vline
WA_J_7LKCV2_STR-LIMRK sy-vline
WA_J_7LKCV2_STR-LIFNR sy-vline
WA_J_7LKCV2_STR-MTART sy-vline
WA_J_7LKCV2_STR-GRUPPE sy-vline
WA_J_7LKCV2_STR-MATKL sy-vline
WA_J_7LKCV2_STR-PRDHA sy-vline
WA_J_7LKCV2_STR-MBRSH sy-vline
WA_J_7LKCV2_STR-GSBER sy-vline
WA_J_7LKCV2_STR-HKUNNR sy-vline
WA_J_7LKCV2_STR-HVKORG sy-vline
WA_J_7LKCV2_STR-HVTWEG sy-vline
WA_J_7LKCV2_STR-HSPART sy-vline
WA_J_7LKCV2_STR-HITYP sy-vline
WA_J_7LKCV2_STR-HISTUNR sy-vline
WA_J_7LKCV2_STR-MATNR sy-vline
WA_J_7LKCV2_STR-VARIANTE sy-vline
WA_J_7LKCV2_STR-POSAR sy-vline
WA_J_7LKCV2_STR-POSAR2 sy-vline
WA_J_7LKCV2_STR-KOART sy-vline
WA_J_7LKCV2_STR-KOKEY sy-vline
WA_J_7LKCV2_STR-KZPRAD sy-vline
WA_J_7LKCV2_STR-SPLIT sy-vline
WA_J_7LKCV2_STR-DATAB sy-vline
WA_J_7LKCV2_STR-DATBI sy-vline
WA_J_7LKCV2_STR-PLVRS sy-vline
WA_J_7LKCV2_STR-SOKOA sy-vline
WA_J_7LKCV2_STR-PLTYP sy-vline
WA_J_7LKCV2_STR-NETWR sy-vline
WA_J_7LKCV2_STR-PGAAWR sy-vline
WA_J_7LKCV2_STR-WAERK sy-vline
WA_J_7LKCV2_STR-NETWE sy-vline
WA_J_7LKCV2_STR-WAERE sy-vline
WA_J_7LKCV2_STR-MENGE sy-vline
WA_J_7LKCV2_STR-MEINS sy-vline
WA_J_7LKCV2_STR-MENGP sy-vline
WA_J_7LKCV2_STR-FKIMG sy-vline
WA_J_7LKCV2_STR-MEINA sy-vline
WA_J_7LKCV2_STR-FKIMP sy-vline
WA_J_7LKCV2_STR-VFLKL sy-vline
WA_J_7LKCV2_STR-VFLST sy-vline
WA_J_7LKCV2_STR-KMEIN sy-vline
WA_J_7LKCV2_STR-STOFE sy-vline
WA_J_7LKCV2_STR-STGEW sy-vline
WA_J_7LKCV2_STR-GEWEI sy-vline
WA_J_7LKCV2_STR-VPEBENE sy-vline
WA_J_7LKCV2_STR-VPARTG sy-vline
WA_J_7LKCV2_STR-VPARTS sy-vline
WA_J_7LKCV2_STR-VRPKT sy-vline
WA_J_7LKCV2_STR-INFOK sy-vline
WA_J_7LKCV2_STR-FUELLG sy-vline
WA_J_7LKCV2_STR-HDLST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.