ABAP Select data from SAP table J_7LBOMINFO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP J_7LBOMINFO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to J_7LBOMINFO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the J_7LBOMINFO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_J_7LBOMINFO TYPE STANDARD TABLE OF J_7LBOMINFO,
      WA_J_7LBOMINFO TYPE J_7LBOMINFO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <J_7LBOMINFO> TYPE J_7LBOMINFO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_J_7LBOMINFO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM J_7LBOMINFO
  INTO TABLE IT_J_7LBOMINFO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM J_7LBOMINFO
*  INTO TABLE @DATA(IT_J_7LBOMINFO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_J_7LBOMINFO INDEX 1 INTO DATA(WA_J_7LBOMINFO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_J_7LBOMINFO ASSIGNING <J_7LBOMINFO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<J_7LBOMINFO>-STLKN = 1.
<J_7LBOMINFO>-MATNR = 1.
<J_7LBOMINFO>-MAKTX = 1.
<J_7LBOMINFO>-STLEV = 1.
<J_7LBOMINFO>-MEINS = 1.
ENDLOOP.

LOOP AT IT_J_7LBOMINFO INTO WA_J_7LBOMINFO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_J_7LBOMINFO-MENGE, sy-vline,
WA_J_7LBOMINFO-VSTAT, sy-vline,
WA_J_7LBOMINFO-BSTAT, sy-vline,
WA_J_7LBOMINFO-VGKNT, sy-vline,
WA_J_7LBOMINFO-WERKS, sy-vline,
WA_J_7LBOMINFO-WERKS_K, sy-vline.
ENDLOOP. *Add any further fields from structure WA_J_7LBOMINFO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_J_7LBOMINFO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_J_7LBOMINFO INTO WA_J_7LBOMINFO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_J_7LBOMINFO-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_7LBOMINFO-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_J_7LBOMINFO-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_7LBOMINFO-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_J_7LBOMINFO-STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_7LBOMINFO-STLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_J_7LBOMINFO-STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_7LBOMINFO-STLAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VMEIN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_J_7LBOMINFO-VMEIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_7LBOMINFO-VMEIN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_J_7LBOMINFO_STR,
STLKN TYPE STRING,
MATNR TYPE STRING,
MAKTX TYPE STRING,
STLEV TYPE STRING,
MEINS TYPE STRING,
MENGE TYPE STRING,
VSTAT TYPE STRING,
BSTAT TYPE STRING,
VGKNT TYPE STRING,
WERKS TYPE STRING,
WERKS_K TYPE STRING,
MWERKSX TYPE STRING,
STLAN TYPE STRING,
STLNR TYPE STRING,
STLAL TYPE STRING,
STLST TYPE STRING,
POSTP TYPE STRING,
MTART TYPE STRING,
VMEIN TYPE STRING,
VMENG TYPE STRING,
RECURSIVE TYPE STRING,
REC_ALLOWD TYPE STRING,
VALIDFROM TYPE STRING,
VALIDTO TYPE STRING,
NODE TYPE STRING,
SELECTED TYPE STRING,
SELECTED_TEXT TYPE STRING,
MEINS_TEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_J_7LBOMINFO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_J_7LBOMINFO_STR-STLKN sy-vline
WA_J_7LBOMINFO_STR-MATNR sy-vline
WA_J_7LBOMINFO_STR-MAKTX sy-vline
WA_J_7LBOMINFO_STR-STLEV sy-vline
WA_J_7LBOMINFO_STR-MEINS sy-vline
WA_J_7LBOMINFO_STR-MENGE sy-vline
WA_J_7LBOMINFO_STR-VSTAT sy-vline
WA_J_7LBOMINFO_STR-BSTAT sy-vline
WA_J_7LBOMINFO_STR-VGKNT sy-vline
WA_J_7LBOMINFO_STR-WERKS sy-vline
WA_J_7LBOMINFO_STR-WERKS_K sy-vline
WA_J_7LBOMINFO_STR-MWERKSX sy-vline
WA_J_7LBOMINFO_STR-STLAN sy-vline
WA_J_7LBOMINFO_STR-STLNR sy-vline
WA_J_7LBOMINFO_STR-STLAL sy-vline
WA_J_7LBOMINFO_STR-STLST sy-vline
WA_J_7LBOMINFO_STR-POSTP sy-vline
WA_J_7LBOMINFO_STR-MTART sy-vline
WA_J_7LBOMINFO_STR-VMEIN sy-vline
WA_J_7LBOMINFO_STR-VMENG sy-vline
WA_J_7LBOMINFO_STR-RECURSIVE sy-vline
WA_J_7LBOMINFO_STR-REC_ALLOWD sy-vline
WA_J_7LBOMINFO_STR-VALIDFROM sy-vline
WA_J_7LBOMINFO_STR-VALIDTO sy-vline
WA_J_7LBOMINFO_STR-NODE sy-vline
WA_J_7LBOMINFO_STR-SELECTED sy-vline
WA_J_7LBOMINFO_STR-SELECTED_TEXT sy-vline
WA_J_7LBOMINFO_STR-MEINS_TEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.