ABAP Select data from SAP table J_2GLPPTCDBV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP J_2GLPPTCDBV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to J_2GLPPTCDBV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the J_2GLPPTCDBV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_J_2GLPPTCDBV TYPE STANDARD TABLE OF J_2GLPPTCDBV,
      WA_J_2GLPPTCDBV TYPE J_2GLPPTCDBV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <J_2GLPPTCDBV> TYPE J_2GLPPTCDBV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_J_2GLPPTCDBV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM J_2GLPPTCDBV
  INTO TABLE IT_J_2GLPPTCDBV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM J_2GLPPTCDBV
*  INTO TABLE @DATA(IT_J_2GLPPTCDBV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_J_2GLPPTCDBV INDEX 1 INTO DATA(WA_J_2GLPPTCDBV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_J_2GLPPTCDBV ASSIGNING <J_2GLPPTCDBV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<J_2GLPPTCDBV>-MANDT = 1.
<J_2GLPPTCDBV>-BUKRS = 1.
<J_2GLPPTCDBV>-PRNTSK = 1.
<J_2GLPPTCDBV>-LOGPAPER = 1.
<J_2GLPPTCDBV>-LOGKIND = 1.
ENDLOOP.

LOOP AT IT_J_2GLPPTCDBV INTO WA_J_2GLPPTCDBV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_J_2GLPPTCDBV-DEVICE, sy-vline,
WA_J_2GLPPTCDBV-PUSER, sy-vline,
WA_J_2GLPPTCDBV-DESCR, sy-vline,
WA_J_2GLPPTCDBV-MANUAL, sy-vline,
WA_J_2GLPPTCDBV-ACTIVE, sy-vline,
WA_J_2GLPPTCDBV-THIRDPARTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_J_2GLPPTCDBV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_J_2GLPPTCDBV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_J_2GLPPTCDBV INTO WA_J_2GLPPTCDBV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit SPDEV, internal->external for field DEVICE CALL FUNCTION 'CONVERSION_EXIT_SPDEV_OUTPUT' EXPORTING input = WA_J_2GLPPTCDBV-DEVICE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_2GLPPTCDBV-DEVICE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_J_2GLPPTCDBV_STR,
MANDT TYPE STRING,
BUKRS TYPE STRING,
PRNTSK TYPE STRING,
LOGPAPER TYPE STRING,
LOGKIND TYPE STRING,
DEVICE TYPE STRING,
PUSER TYPE STRING,
DESCR TYPE STRING,
MANUAL TYPE STRING,
ACTIVE TYPE STRING,
THIRDPARTY TYPE STRING,
STEXT TYPE STRING,
SERIES TYPE STRING,
LASTDATE TYPE STRING,
RFPRNTSK TYPE STRING,END OF T_EKKO_STR. DATA: WA_J_2GLPPTCDBV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_J_2GLPPTCDBV_STR-MANDT sy-vline
WA_J_2GLPPTCDBV_STR-BUKRS sy-vline
WA_J_2GLPPTCDBV_STR-PRNTSK sy-vline
WA_J_2GLPPTCDBV_STR-LOGPAPER sy-vline
WA_J_2GLPPTCDBV_STR-LOGKIND sy-vline
WA_J_2GLPPTCDBV_STR-DEVICE sy-vline
WA_J_2GLPPTCDBV_STR-PUSER sy-vline
WA_J_2GLPPTCDBV_STR-DESCR sy-vline
WA_J_2GLPPTCDBV_STR-MANUAL sy-vline
WA_J_2GLPPTCDBV_STR-ACTIVE sy-vline
WA_J_2GLPPTCDBV_STR-THIRDPARTY sy-vline
WA_J_2GLPPTCDBV_STR-STEXT sy-vline
WA_J_2GLPPTCDBV_STR-SERIES sy-vline
WA_J_2GLPPTCDBV_STR-LASTDATE sy-vline
WA_J_2GLPPTCDBV_STR-RFPRNTSK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.