ABAP Select data from SAP table IWCBSK__VH1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IWCBSK__VH1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IWCBSK__VH1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IWCBSK__VH1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IWCBSK__VH1 TYPE STANDARD TABLE OF IWCBSK__VH1,
      WA_IWCBSK__VH1 TYPE IWCBSK__VH1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IWCBSK__VH1> TYPE IWCBSK__VH1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IWCBSK__VH1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IWCBSK__VH1
  INTO TABLE IT_IWCBSK__VH1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IWCBSK__VH1
*  INTO TABLE @DATA(IT_IWCBSK__VH12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IWCBSK__VH1 INDEX 1 INTO DATA(WA_IWCBSK__VH12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IWCBSK__VH1 ASSIGNING <IWCBSK__VH1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IWCBSK__VH1>-MANDT = 1.
<IWCBSK__VH1>-PLANT = 1.
<IWCBSK__VH1>-WORKCENTER = 1.
<IWCBSK__VH1>-WORKCENTERINTERNALID = 1.
<IWCBSK__VH1>-WORKCENTERTYPECODE = 1.
ENDLOOP.

LOOP AT IT_IWCBSK__VH1 INTO WA_IWCBSK__VH1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IWCBSK__VH1-WORKCENTERISTOBEDELETED, sy-vline,
WA_IWCBSK__VH1-WORKCENTERISLOCKED, sy-vline,
WA_IWCBSK__VH1-WORKCENTERISMNTNDFORCOSTING, sy-vline,
WA_IWCBSK__VH1-WORKCENTERISMNTNDFORSCHEDULING, sy-vline,
WA_IWCBSK__VH1-NUMBEROFCONFIRMATIONSLIPS, sy-vline,
WA_IWCBSK__VH1-WORKCENTERCATEGORYCODE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IWCBSK__VH1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IWCBSK__VH1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IWCBSK__VH1 INTO WA_IWCBSK__VH1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field WORKCENTERSTDQUEUEDURNUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IWCBSK__VH1-WORKCENTERSTDQUEUEDURNUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IWCBSK__VH1-WORKCENTERSTDQUEUEDURNUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WORKCENTERMINIMUMQUEUEDURNUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IWCBSK__VH1-WORKCENTERMINIMUMQUEUEDURNUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IWCBSK__VH1-WORKCENTERMINIMUMQUEUEDURNUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WORKCENTERSTANDARDWORKQTYUNIT1 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IWCBSK__VH1-WORKCENTERSTANDARDWORKQTYUNIT1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IWCBSK__VH1-WORKCENTERSTANDARDWORKQTYUNIT1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WORKCENTERSTANDARDWORKQTYUNIT2 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IWCBSK__VH1-WORKCENTERSTANDARDWORKQTYUNIT2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IWCBSK__VH1-WORKCENTERSTANDARDWORKQTYUNIT2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WORKCENTERSTANDARDWORKQTYUNIT3 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IWCBSK__VH1-WORKCENTERSTANDARDWORKQTYUNIT3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IWCBSK__VH1-WORKCENTERSTANDARDWORKQTYUNIT3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WORKCENTERSTANDARDWORKQTYUNIT4 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IWCBSK__VH1-WORKCENTERSTANDARDWORKQTYUNIT4 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IWCBSK__VH1-WORKCENTERSTANDARDWORKQTYUNIT4.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WORKCENTERSTANDARDWORKQTYUNIT5 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IWCBSK__VH1-WORKCENTERSTANDARDWORKQTYUNIT5 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IWCBSK__VH1-WORKCENTERSTANDARDWORKQTYUNIT5.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WORKCENTERSTANDARDWORKQTYUNIT6 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IWCBSK__VH1-WORKCENTERSTANDARDWORKQTYUNIT6 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IWCBSK__VH1-WORKCENTERSTANDARDWORKQTYUNIT6.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field STANDARDWORKQUANTITYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IWCBSK__VH1-STANDARDWORKQUANTITYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IWCBSK__VH1-STANDARDWORKQUANTITYUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IWCBSK__VH1_STR,
MANDT TYPE STRING,
PLANT TYPE STRING,
WORKCENTER TYPE STRING,
WORKCENTERINTERNALID TYPE STRING,
WORKCENTERTYPECODE TYPE STRING,
WORKCENTERISTOBEDELETED TYPE STRING,
WORKCENTERISLOCKED TYPE STRING,
WORKCENTERISMNTNDFORCOSTING TYPE STRING,
WORKCENTERISMNTNDFORSCHEDULING TYPE STRING,
NUMBEROFCONFIRMATIONSLIPS TYPE STRING,
WORKCENTERCATEGORYCODE TYPE STRING,
WORKCENTERLOCATION TYPE STRING,
WORKCENTERLOCATIONGROUP TYPE STRING,
WORKCENTERUSAGE TYPE STRING,
WORKCENTERRESPONSIBLE TYPE STRING,
SUPPLYAREA TYPE STRING,
CAPACITYINTERNALID TYPE STRING,
MACHINETYPE TYPE STRING,
OPERATIONCONTROLPROFILE TYPE STRING,
MATLCOMPISMARKEDFORBACKFLUSH TYPE STRING,
WORKCENTERSETUPTYPE TYPE STRING,
FREEDEFINEDTABLEFIELDSEMANTIC TYPE STRING,
OBJECTINTERNALID TYPE STRING,
STANDARDTEXTINTERNALID TYPE STRING,
EMPLOYEEWAGETYPE TYPE STRING,
EMPLOYEEWAGEGROUP TYPE STRING,
EMPLOYEESUITABILITY TYPE STRING,
NUMBEROFTIMETICKETS TYPE STRING,
PLANVERSION TYPE STRING,
VALIDITYSTARTDATE TYPE STRING,
VALIDITYENDDATE TYPE STRING,
STANDARDTEXTIDISREFERENCED TYPE STRING,
EMPLOYEEWAGETYPEISREFERENCED TYPE STRING,
NMBROFTIMETICKETSISREFERENCED TYPE STRING,
EMPLOYEEWAGEGROUPISREFERENCED TYPE STRING,
EMPLSUITABILITYISREFERENCED TYPE STRING,
WORKCENTERSETPTYPEISREFERENCED TYPE STRING,
OPCONTROLPROFILEISREFERENCED TYPE STRING,
NUMBEROFCONFSLIPSISREFERENCED TYPE STRING,
WORKCENTERSTDQUEUEDURNUNIT TYPE STRING,
WORKCENTERSTANDARDQUEUEDURN TYPE STRING,
WORKCENTERMINIMUMQUEUEDURNUNIT TYPE STRING,
WORKCENTERMINIMUMQUEUEDURATION TYPE STRING,
WORKCENTERSTANDARDWORKQTYUNIT1 TYPE STRING,
WORKCENTERSTANDARDWORKQTYUNIT2 TYPE STRING,
WORKCENTERSTANDARDWORKQTYUNIT3 TYPE STRING,
WORKCENTERSTANDARDWORKQTYUNIT4 TYPE STRING,
WORKCENTERSTANDARDWORKQTYUNIT5 TYPE STRING,
WORKCENTERSTANDARDWORKQTYUNIT6 TYPE STRING,
STANDARDWORKQUANTITYUNIT TYPE STRING,END OF T_EKKO_STR. DATA: WA_IWCBSK__VH1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IWCBSK__VH1_STR-MANDT sy-vline
WA_IWCBSK__VH1_STR-PLANT sy-vline
WA_IWCBSK__VH1_STR-WORKCENTER sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERINTERNALID sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERTYPECODE sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERISTOBEDELETED sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERISLOCKED sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERISMNTNDFORCOSTING sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERISMNTNDFORSCHEDULING sy-vline
WA_IWCBSK__VH1_STR-NUMBEROFCONFIRMATIONSLIPS sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERCATEGORYCODE sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERLOCATION sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERLOCATIONGROUP sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERUSAGE sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERRESPONSIBLE sy-vline
WA_IWCBSK__VH1_STR-SUPPLYAREA sy-vline
WA_IWCBSK__VH1_STR-CAPACITYINTERNALID sy-vline
WA_IWCBSK__VH1_STR-MACHINETYPE sy-vline
WA_IWCBSK__VH1_STR-OPERATIONCONTROLPROFILE sy-vline
WA_IWCBSK__VH1_STR-MATLCOMPISMARKEDFORBACKFLUSH sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERSETUPTYPE sy-vline
WA_IWCBSK__VH1_STR-FREEDEFINEDTABLEFIELDSEMANTIC sy-vline
WA_IWCBSK__VH1_STR-OBJECTINTERNALID sy-vline
WA_IWCBSK__VH1_STR-STANDARDTEXTINTERNALID sy-vline
WA_IWCBSK__VH1_STR-EMPLOYEEWAGETYPE sy-vline
WA_IWCBSK__VH1_STR-EMPLOYEEWAGEGROUP sy-vline
WA_IWCBSK__VH1_STR-EMPLOYEESUITABILITY sy-vline
WA_IWCBSK__VH1_STR-NUMBEROFTIMETICKETS sy-vline
WA_IWCBSK__VH1_STR-PLANVERSION sy-vline
WA_IWCBSK__VH1_STR-VALIDITYSTARTDATE sy-vline
WA_IWCBSK__VH1_STR-VALIDITYENDDATE sy-vline
WA_IWCBSK__VH1_STR-STANDARDTEXTIDISREFERENCED sy-vline
WA_IWCBSK__VH1_STR-EMPLOYEEWAGETYPEISREFERENCED sy-vline
WA_IWCBSK__VH1_STR-NMBROFTIMETICKETSISREFERENCED sy-vline
WA_IWCBSK__VH1_STR-EMPLOYEEWAGEGROUPISREFERENCED sy-vline
WA_IWCBSK__VH1_STR-EMPLSUITABILITYISREFERENCED sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERSETPTYPEISREFERENCED sy-vline
WA_IWCBSK__VH1_STR-OPCONTROLPROFILEISREFERENCED sy-vline
WA_IWCBSK__VH1_STR-NUMBEROFCONFSLIPSISREFERENCED sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERSTDQUEUEDURNUNIT sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERSTANDARDQUEUEDURN sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERMINIMUMQUEUEDURNUNIT sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERMINIMUMQUEUEDURATION sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERSTANDARDWORKQTYUNIT1 sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERSTANDARDWORKQTYUNIT2 sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERSTANDARDWORKQTYUNIT3 sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERSTANDARDWORKQTYUNIT4 sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERSTANDARDWORKQTYUNIT5 sy-vline
WA_IWCBSK__VH1_STR-WORKCENTERSTANDARDWORKQTYUNIT6 sy-vline
WA_IWCBSK__VH1_STR-STANDARDWORKQUANTITYUNIT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.