ABAP Select data from SAP table IVARCONFSIMVH into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IVARCONFSIMVH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IVARCONFSIMVH. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IVARCONFSIMVH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IVARCONFSIMVH TYPE STANDARD TABLE OF IVARCONFSIMVH,
      WA_IVARCONFSIMVH TYPE IVARCONFSIMVH,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IVARCONFSIMVH> TYPE IVARCONFSIMVH.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IVARCONFSIMVH.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IVARCONFSIMVH
  INTO TABLE IT_IVARCONFSIMVH.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IVARCONFSIMVH
*  INTO TABLE @DATA(IT_IVARCONFSIMVH2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IVARCONFSIMVH INDEX 1 INTO DATA(WA_IVARCONFSIMVH2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IVARCONFSIMVH ASSIGNING <IVARCONFSIMVH>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IVARCONFSIMVH>-MANDT = 1.
<IVARCONFSIMVH>-CONFIGURATIONSIMULATIONUUID = 1.
<IVARCONFSIMVH>-CONFIGURATIONNUMBER = 1.
<IVARCONFSIMVH>-CONFIGURATIONSIMULATIONNAME = 1.
<IVARCONFSIMVH>-CONFIGURATIONSIMULATIONDESC = 1.
ENDLOOP.

LOOP AT IT_IVARCONFSIMVH INTO WA_IVARCONFSIMVH.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IVARCONFSIMVH-PRODUCT, sy-vline,
WA_IVARCONFSIMVH-PRODUCTNAME, sy-vline,
WA_IVARCONFSIMVH-PLANT, sy-vline,
WA_IVARCONFSIMVH-CONFIGURATIONSIMULATIONDATE, sy-vline,
WA_IVARCONFSIMVH-BOMEXPLOSIONAPPLICATION, sy-vline,
WA_IVARCONFSIMVH-CREATEDBYUSER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IVARCONFSIMVH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IVARCONFSIMVH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IVARCONFSIMVH INTO WA_IVARCONFSIMVH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field PRODUCT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IVARCONFSIMVH-PRODUCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IVARCONFSIMVH-PRODUCT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IVARCONFSIMVH_STR,
MANDT TYPE STRING,
CONFIGURATIONSIMULATIONUUID TYPE STRING,
CONFIGURATIONNUMBER TYPE STRING,
CONFIGURATIONSIMULATIONNAME TYPE STRING,
CONFIGURATIONSIMULATIONDESC TYPE STRING,
PRODUCT TYPE STRING,
PRODUCTNAME TYPE STRING,
PLANT TYPE STRING,
CONFIGURATIONSIMULATIONDATE TYPE STRING,
BOMEXPLOSIONAPPLICATION TYPE STRING,
CREATEDBYUSER TYPE STRING,
CREATIONDATE TYPE STRING,
CREATIONTIME TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
LASTCHANGEDATE TYPE STRING,
LASTCHANGETIME TYPE STRING,
CONFIGURATIONPROFILENUMBER TYPE STRING,
CONFIGURATIONPROFILENAME TYPE STRING,
CONFIGURATIONPROFILESTATUS TYPE STRING,
ENGINEPROCESSINGMODE TYPE STRING,
AUTHORIZATIONGROUP TYPE STRING,
PRODUCTTYPE TYPE STRING,
PRODUCTGROUP TYPE STRING,END OF T_EKKO_STR. DATA: WA_IVARCONFSIMVH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IVARCONFSIMVH_STR-MANDT sy-vline
WA_IVARCONFSIMVH_STR-CONFIGURATIONSIMULATIONUUID sy-vline
WA_IVARCONFSIMVH_STR-CONFIGURATIONNUMBER sy-vline
WA_IVARCONFSIMVH_STR-CONFIGURATIONSIMULATIONNAME sy-vline
WA_IVARCONFSIMVH_STR-CONFIGURATIONSIMULATIONDESC sy-vline
WA_IVARCONFSIMVH_STR-PRODUCT sy-vline
WA_IVARCONFSIMVH_STR-PRODUCTNAME sy-vline
WA_IVARCONFSIMVH_STR-PLANT sy-vline
WA_IVARCONFSIMVH_STR-CONFIGURATIONSIMULATIONDATE sy-vline
WA_IVARCONFSIMVH_STR-BOMEXPLOSIONAPPLICATION sy-vline
WA_IVARCONFSIMVH_STR-CREATEDBYUSER sy-vline
WA_IVARCONFSIMVH_STR-CREATIONDATE sy-vline
WA_IVARCONFSIMVH_STR-CREATIONTIME sy-vline
WA_IVARCONFSIMVH_STR-LASTCHANGEDBYUSER sy-vline
WA_IVARCONFSIMVH_STR-LASTCHANGEDATE sy-vline
WA_IVARCONFSIMVH_STR-LASTCHANGETIME sy-vline
WA_IVARCONFSIMVH_STR-CONFIGURATIONPROFILENUMBER sy-vline
WA_IVARCONFSIMVH_STR-CONFIGURATIONPROFILENAME sy-vline
WA_IVARCONFSIMVH_STR-CONFIGURATIONPROFILESTATUS sy-vline
WA_IVARCONFSIMVH_STR-ENGINEPROCESSINGMODE sy-vline
WA_IVARCONFSIMVH_STR-AUTHORIZATIONGROUP sy-vline
WA_IVARCONFSIMVH_STR-PRODUCTTYPE sy-vline
WA_IVARCONFSIMVH_STR-PRODUCTGROUP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.