ABAP Select data from SAP table IUUC_REPL_EN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IUUC_REPL_EN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IUUC_REPL_EN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IUUC_REPL_EN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IUUC_REPL_EN TYPE STANDARD TABLE OF IUUC_REPL_EN,
      WA_IUUC_REPL_EN TYPE IUUC_REPL_EN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IUUC_REPL_EN> TYPE IUUC_REPL_EN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IUUC_REPL_EN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IUUC_REPL_EN
  INTO TABLE IT_IUUC_REPL_EN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IUUC_REPL_EN
*  INTO TABLE @DATA(IT_IUUC_REPL_EN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IUUC_REPL_EN INDEX 1 INTO DATA(WA_IUUC_REPL_EN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IUUC_REPL_EN ASSIGNING <IUUC_REPL_EN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IUUC_REPL_EN>-MT_ID = 1.
<IUUC_REPL_EN>-EN_ACTIVE = 1.
<IUUC_REPL_EN>-SCH_INTERVAL = 1.
<IUUC_REPL_EN>-NOTIFY_REPEAT = 1.
<IUUC_REPL_EN>-CHECK_MASTER_JOB = 1.
ENDLOOP.

LOOP AT IT_IUUC_REPL_EN INTO WA_IUUC_REPL_EN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IUUC_REPL_EN-CHECK_CONNECTION, sy-vline,
WA_IUUC_REPL_EN-CHECK_LOAD_JOBS, sy-vline,
WA_IUUC_REPL_EN-CHECK_TRIGGER, sy-vline,
WA_IUUC_REPL_EN-CHECK_LOGTAB, sy-vline,
WA_IUUC_REPL_EN-CHECK_LATENCY, sy-vline,
WA_IUUC_REPL_EN-CHECK_REPL_STG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IUUC_REPL_EN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IUUC_REPL_EN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IUUC_REPL_EN INTO WA_IUUC_REPL_EN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit SXIDN, internal->external for field EMAIL_SENDER CALL FUNCTION 'CONVERSION_EXIT_SXIDN_OUTPUT' EXPORTING input = WA_IUUC_REPL_EN-EMAIL_SENDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IUUC_REPL_EN-EMAIL_SENDER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IUUC_REPL_EN_STR,
MT_ID TYPE STRING,
EN_ACTIVE TYPE STRING,
SCH_INTERVAL TYPE STRING,
NOTIFY_REPEAT TYPE STRING,
CHECK_MASTER_JOB TYPE STRING,
CHECK_CONNECTION TYPE STRING,
CHECK_LOAD_JOBS TYPE STRING,
CHECK_TRIGGER TYPE STRING,
CHECK_LOGTAB TYPE STRING,
CHECK_LATENCY TYPE STRING,
CHECK_REPL_STG TYPE STRING,
CHECK_SYN TYPE STRING,
CHECK_TARGET_TAB TYPE STRING,
CHECK_LANGUAGE TYPE STRING,
LAST_RUN TYPE STRING,
LAST_NOTIFY TYPE STRING,
EMAIL_SENDER TYPE STRING,END OF T_EKKO_STR. DATA: WA_IUUC_REPL_EN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IUUC_REPL_EN_STR-MT_ID sy-vline
WA_IUUC_REPL_EN_STR-EN_ACTIVE sy-vline
WA_IUUC_REPL_EN_STR-SCH_INTERVAL sy-vline
WA_IUUC_REPL_EN_STR-NOTIFY_REPEAT sy-vline
WA_IUUC_REPL_EN_STR-CHECK_MASTER_JOB sy-vline
WA_IUUC_REPL_EN_STR-CHECK_CONNECTION sy-vline
WA_IUUC_REPL_EN_STR-CHECK_LOAD_JOBS sy-vline
WA_IUUC_REPL_EN_STR-CHECK_TRIGGER sy-vline
WA_IUUC_REPL_EN_STR-CHECK_LOGTAB sy-vline
WA_IUUC_REPL_EN_STR-CHECK_LATENCY sy-vline
WA_IUUC_REPL_EN_STR-CHECK_REPL_STG sy-vline
WA_IUUC_REPL_EN_STR-CHECK_SYN sy-vline
WA_IUUC_REPL_EN_STR-CHECK_TARGET_TAB sy-vline
WA_IUUC_REPL_EN_STR-CHECK_LANGUAGE sy-vline
WA_IUUC_REPL_EN_STR-LAST_RUN sy-vline
WA_IUUC_REPL_EN_STR-LAST_NOTIFY sy-vline
WA_IUUC_REPL_EN_STR-EMAIL_SENDER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.