ABAP Select data from SAP table ISWORKFLOWTEMPLATE_D into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISWORKFLOWTEMPLATE_D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISWORKFLOWTEMPLATE_D. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ISWORKFLOWTEMPLATE_D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ISWORKFLOWTEMPLATE_D TYPE STANDARD TABLE OF ISWORKFLOWTEMPLATE_D,
      WA_ISWORKFLOWTEMPLATE_D TYPE ISWORKFLOWTEMPLATE_D,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ISWORKFLOWTEMPLATE_D> TYPE ISWORKFLOWTEMPLATE_D.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ISWORKFLOWTEMPLATE_D.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ISWORKFLOWTEMPLATE_D
  INTO TABLE IT_ISWORKFLOWTEMPLATE_D.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ISWORKFLOWTEMPLATE_D
*  INTO TABLE @DATA(IT_ISWORKFLOWTEMPLATE_D2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ISWORKFLOWTEMPLATE_D INDEX 1 INTO DATA(WA_ISWORKFLOWTEMPLATE_D2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ISWORKFLOWTEMPLATE_D ASSIGNING <ISWORKFLOWTEMPLATE_D>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISWORKFLOWTEMPLATE_D>-WRKFLWTMPLID = 1.
<ISWORKFLOWTEMPLATE_D>-WRKFLWTMPLNAME = 1.
<ISWORKFLOWTEMPLATE_D>-WRKFLWTMPLNAMESEARCH = 1.
<ISWORKFLOWTEMPLATE_D>-WRKFLWTMPLNAMESEARCHA = 1.
<ISWORKFLOWTEMPLATE_D>-WRKFLWTMPLNAMESEARCHB = 1.
ENDLOOP.

LOOP AT IT_ISWORKFLOWTEMPLATE_D INTO WA_ISWORKFLOWTEMPLATE_D.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ISWORKFLOWTEMPLATE_D-WRKFLWTMPLNAMESEARCHC, sy-vline,
WA_ISWORKFLOWTEMPLATE_D-WRKFLWTMPLNAMESEARCHD, sy-vline,
WA_ISWORKFLOWTEMPLATE_D-WRKFLWSCEN, sy-vline,
WA_ISWORKFLOWTEMPLATE_D-SAPAPPLICATIONCOMPONENT, sy-vline,
WA_ISWORKFLOWTEMPLATE_D-WRKFLWSCENVERS, sy-vline,
WA_ISWORKFLOWTEMPLATE_D-WRKFLWTMPLTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISWORKFLOWTEMPLATE_D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISWORKFLOWTEMPLATE_D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISWORKFLOWTEMPLATE_D INTO WA_ISWORKFLOWTEMPLATE_D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field WRKFLWTMPLCRTEDLANG CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_ISWORKFLOWTEMPLATE_D-WRKFLWTMPLCRTEDLANG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISWORKFLOWTEMPLATE_D-WRKFLWTMPLCRTEDLANG.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISWORKFLOWTEMPLATE_D_STR,
WRKFLWTMPLID TYPE STRING,
WRKFLWTMPLNAME TYPE STRING,
WRKFLWTMPLNAMESEARCH TYPE STRING,
WRKFLWTMPLNAMESEARCHA TYPE STRING,
WRKFLWTMPLNAMESEARCHB TYPE STRING,
WRKFLWTMPLNAMESEARCHC TYPE STRING,
WRKFLWTMPLNAMESEARCHD TYPE STRING,
WRKFLWSCEN TYPE STRING,
SAPAPPLICATIONCOMPONENT TYPE STRING,
WRKFLWSCENVERS TYPE STRING,
WRKFLWTMPLTYPE TYPE STRING,
WRKFLWTMPLSTAGE TYPE STRING,
WRKFLWTMPLGENERICPRPTY1 TYPE STRING,
WRKFLWTMPLGENERICPRPTY2 TYPE STRING,
WRKFLWTMPLGENERICPRPTY3 TYPE STRING,
WRKFLWTMPLGENERICPRPTY4 TYPE STRING,
WRKFLWTMPLGENERICPRPTY5 TYPE STRING,
WRKFLWTMPLGENERICPRPTY6 TYPE STRING,
WRKFLWTMPLGENERICPRPTY7 TYPE STRING,
WRKFLWTMPLGENERICPRPTY8 TYPE STRING,
WRKFLWTMPLGENERICPRPTY9 TYPE STRING,
WRKFLWTMPLGENERICPRPTY10 TYPE STRING,
WRKFLWTMPLCRTEDLANG TYPE STRING,
WRKFLWTMPLCRTEDUSR TYPE STRING,
WRKFLWTMPLCRTEDUTCDTETME TYPE STRING,
WRKFLWTMPLLASTCHGDUSR TYPE STRING,
WRKFLWTMPLLASTCHGDUTCDTETME TYPE STRING,
WRKFLWTMPLTRANSPORTED TYPE STRING,
ISDELETED TYPE STRING,
ACTIVEUUID TYPE STRING,
HASACTIVEENTITY TYPE STRING,
DRAFTENTITYCREATIONDATETIME TYPE STRING,
DRAFTENTITYLASTCHANGEDATETIME TYPE STRING,
DRAFTADMINISTRATIVEDATAUUID TYPE STRING,
DRAFTENTITYCONSISTENCYSTATUS TYPE STRING,
DRAFTENTITYOPERATIONCODE TYPE STRING,
ISACTIVEENTITY TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISWORKFLOWTEMPLATE_D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLID sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLNAME sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLNAMESEARCH sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLNAMESEARCHA sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLNAMESEARCHB sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLNAMESEARCHC sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLNAMESEARCHD sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWSCEN sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-SAPAPPLICATIONCOMPONENT sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWSCENVERS sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLTYPE sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLSTAGE sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLGENERICPRPTY1 sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLGENERICPRPTY2 sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLGENERICPRPTY3 sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLGENERICPRPTY4 sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLGENERICPRPTY5 sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLGENERICPRPTY6 sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLGENERICPRPTY7 sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLGENERICPRPTY8 sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLGENERICPRPTY9 sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLGENERICPRPTY10 sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLCRTEDLANG sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLCRTEDUSR sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLCRTEDUTCDTETME sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLLASTCHGDUSR sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLLASTCHGDUTCDTETME sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-WRKFLWTMPLTRANSPORTED sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-ISDELETED sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-ACTIVEUUID sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-HASACTIVEENTITY sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-DRAFTENTITYCREATIONDATETIME sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-DRAFTENTITYLASTCHANGEDATETIME sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-DRAFTADMINISTRATIVEDATAUUID sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-DRAFTENTITYCONSISTENCYSTATUS sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-DRAFTENTITYOPERATIONCODE sy-vline
WA_ISWORKFLOWTEMPLATE_D_STR-ISACTIVEENTITY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.