ABAP Select data from SAP table ISUEXT_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISUEXT_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISUEXT_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ISUEXT_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ISUEXT_DATA TYPE STANDARD TABLE OF ISUEXT_DATA,
      WA_ISUEXT_DATA TYPE ISUEXT_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ISUEXT_DATA> TYPE ISUEXT_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ISUEXT_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ISUEXT_DATA
  INTO TABLE IT_ISUEXT_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ISUEXT_DATA
*  INTO TABLE @DATA(IT_ISUEXT_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ISUEXT_DATA INDEX 1 INTO DATA(WA_ISUEXT_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ISUEXT_DATA ASSIGNING <ISUEXT_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISUEXT_DATA>-ISUCONTR = 1.
<ISUEXT_DATA>-ISULOGSYS = 1.
<ISUEXT_DATA>-NEXTITEM = 1.
<ISUEXT_DATA>-RELPREV = 1.
<ISUEXT_DATA>-PREVITEM = 1.
ENDLOOP.

LOOP AT IT_ISUEXT_DATA INTO WA_ISUEXT_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ISUEXT_DATA-RELNEXT, sy-vline,
WA_ISUEXT_DATA-RELITEM, sy-vline,
WA_ISUEXT_DATA-BPNO, sy-vline,
WA_ISUEXT_DATA-BPGUID, sy-vline,
WA_ISUEXT_DATA-BUAGGUID, sy-vline,
WA_ISUEXT_DATA-PODGUID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISUEXT_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISUEXT_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISUEXT_DATA INTO WA_ISUEXT_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BPNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISUEXT_DATA-BPNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISUEXT_DATA-BPNO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISUEXT_DATA_STR,
ISUCONTR TYPE STRING,
ISULOGSYS TYPE STRING,
NEXTITEM TYPE STRING,
RELPREV TYPE STRING,
PREVITEM TYPE STRING,
RELNEXT TYPE STRING,
RELITEM TYPE STRING,
BPNO TYPE STRING,
BPGUID TYPE STRING,
BUAGGUID TYPE STRING,
PODGUID TYPE STRING,
CONTSTART TYPE STRING,
CONTEND TYPE STRING,
CONTDUR TYPE STRING,
VALIDFROM TYPE STRING,
VALIDTO TYPE STRING,
QUOTATION TYPE STRING,
CANCELLED TYPE STRING,
BLOCKED TYPE STRING,
DIVISION TYPE STRING,
CANDI TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISUEXT_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISUEXT_DATA_STR-ISUCONTR sy-vline
WA_ISUEXT_DATA_STR-ISULOGSYS sy-vline
WA_ISUEXT_DATA_STR-NEXTITEM sy-vline
WA_ISUEXT_DATA_STR-RELPREV sy-vline
WA_ISUEXT_DATA_STR-PREVITEM sy-vline
WA_ISUEXT_DATA_STR-RELNEXT sy-vline
WA_ISUEXT_DATA_STR-RELITEM sy-vline
WA_ISUEXT_DATA_STR-BPNO sy-vline
WA_ISUEXT_DATA_STR-BPGUID sy-vline
WA_ISUEXT_DATA_STR-BUAGGUID sy-vline
WA_ISUEXT_DATA_STR-PODGUID sy-vline
WA_ISUEXT_DATA_STR-CONTSTART sy-vline
WA_ISUEXT_DATA_STR-CONTEND sy-vline
WA_ISUEXT_DATA_STR-CONTDUR sy-vline
WA_ISUEXT_DATA_STR-VALIDFROM sy-vline
WA_ISUEXT_DATA_STR-VALIDTO sy-vline
WA_ISUEXT_DATA_STR-QUOTATION sy-vline
WA_ISUEXT_DATA_STR-CANCELLED sy-vline
WA_ISUEXT_DATA_STR-BLOCKED sy-vline
WA_ISUEXT_DATA_STR-DIVISION sy-vline
WA_ISUEXT_DATA_STR-CANDI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.