ABAP Select data from SAP table ISU_PODMEASTASK005R_MEASTASK into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISU_PODMEASTASK005R_MEASTASK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISU_PODMEASTASK005R_MEASTASK. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ISU_PODMEASTASK005R_MEASTASK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ISU_PODMEASTASK005R_MEASTASK TYPE STANDARD TABLE OF ISU_PODMEASTASK005R_MEASTASK,
      WA_ISU_PODMEASTASK005R_MEASTASK TYPE ISU_PODMEASTASK005R_MEASTASK,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ISU_PODMEASTASK005R_MEASTASK> TYPE ISU_PODMEASTASK005R_MEASTASK.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ISU_PODMEASTASK005R_MEASTASK.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ISU_PODMEASTASK005R_MEASTASK
  INTO TABLE IT_ISU_PODMEASTASK005R_MEASTASK.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ISU_PODMEASTASK005R_MEASTASK
*  INTO TABLE @DATA(IT_ISU_PODMEASTASK005R_MEASTASK2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ISU_PODMEASTASK005R_MEASTASK INDEX 1 INTO DATA(WA_ISU_PODMEASTASK005R_MEASTASK2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ISU_PODMEASTASK005R_MEASTASK ASSIGNING <ISU_PODMEASTASK005R_MEASTASK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISU_PODMEASTASK005R_MEASTASK>-CONTROLLER = 1.
<ISU_PODMEASTASK005R_MEASTASK>-MEASUREMENTTASKID = 1.
<ISU_PODMEASTASK005R_MEASTASK>-CONTROLLER = 1.
<ISU_PODMEASTASK005R_MEASTASK>-SCHEME_ID = 1.
<ISU_PODMEASTASK005R_MEASTASK>-SCHEME_AGENCY_ID = 1.
ENDLOOP.

LOOP AT IT_ISU_PODMEASTASK005R_MEASTASK INTO WA_ISU_PODMEASTASK005R_MEASTASK.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ISU_PODMEASTASK005R_MEASTASK-CONTENT, sy-vline,
WA_ISU_PODMEASTASK005R_MEASTASK-OBJECTIDENTIFICATIONSYSTEMCODE, sy-vline,
WA_ISU_PODMEASTASK005R_MEASTASK-MEASUREMENTTASKCATEGORYCODE, sy-vline,
WA_ISU_PODMEASTASK005R_MEASTASK-MEASUREMENTRECURRENCECODE, sy-vline,
WA_ISU_PODMEASTASK005R_MEASTASK-CONTROLLER, sy-vline,
WA_ISU_PODMEASTASK005R_MEASTASK-LIST_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISU_PODMEASTASK005R_MEASTASK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISU_PODMEASTASK005R_MEASTASK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISU_PODMEASTASK005R_MEASTASK INTO WA_ISU_PODMEASTASK005R_MEASTASK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISU_PODMEASTASK005R_MEASTASK_STR,
CONTROLLER TYPE STRING,
MEASUREMENTTASKID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
CONTENT TYPE STRING,
OBJECTIDENTIFICATIONSYSTEMCODE TYPE STRING,
MEASUREMENTTASKCATEGORYCODE TYPE STRING,
MEASUREMENTRECURRENCECODE TYPE STRING,
CONTROLLER TYPE STRING,
LIST_ID TYPE STRING,
LIST_AGENCY_ID TYPE STRING,
CONTENT TYPE STRING,
SPECIFICATIONS TYPE STRING,
CONTROLLER TYPE STRING,
TIMEOFUSECODE TYPE STRING,
CONTROLLER TYPE STRING,
LIST_ID TYPE STRING,
LIST_AGENCY_ID TYPE STRING,
CONTENT TYPE STRING,
MEASUREUNITCODE TYPE STRING,
DECIMALVALUEPRECISION TYPE STRING,
CONTROLLER TYPE STRING,
TOTALDIGITNUMBERVALUE TYPE STRING,
FRACTIONDIGITNUMBERVALUE TYPE STRING,
DEVICE TYPE STRING,
CONTROLLER TYPE STRING,
DEVICEID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
CONTENT TYPE STRING,
SERIALID TYPE STRING,
MATERIALID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
CONTENT TYPE STRING,
PRODUCTUNIQUEITEMID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
CONTENT TYPE STRING,
INDIVIDUALMATERIALMANUFACTURE TYPE STRING,
CONTROLLER TYPE STRING,
PARTYINTERNALID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
CONTENT TYPE STRING,
PARTNUMBERID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
CONTENT TYPE STRING,
SERIALID TYPE STRING,
SMARTMETERCAPABILITIES TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISU_PODMEASTASK005R_MEASTASK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTROLLER sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-MEASUREMENTTASKID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTROLLER sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-SCHEME_ID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-SCHEME_AGENCY_ID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTENT sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-OBJECTIDENTIFICATIONSYSTEMCODE sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-MEASUREMENTTASKCATEGORYCODE sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-MEASUREMENTRECURRENCECODE sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTROLLER sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-LIST_ID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-LIST_AGENCY_ID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTENT sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-SPECIFICATIONS sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTROLLER sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-TIMEOFUSECODE sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTROLLER sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-LIST_ID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-LIST_AGENCY_ID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTENT sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-MEASUREUNITCODE sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-DECIMALVALUEPRECISION sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTROLLER sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-TOTALDIGITNUMBERVALUE sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-FRACTIONDIGITNUMBERVALUE sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-DEVICE sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTROLLER sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-DEVICEID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTROLLER sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-SCHEME_ID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-SCHEME_AGENCY_ID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTENT sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-SERIALID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-MATERIALID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTROLLER sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-SCHEME_ID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-SCHEME_AGENCY_ID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTENT sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-PRODUCTUNIQUEITEMID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTROLLER sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-SCHEME_ID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-SCHEME_AGENCY_ID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTENT sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-INDIVIDUALMATERIALMANUFACTURE sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTROLLER sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-PARTYINTERNALID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTROLLER sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-SCHEME_ID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-SCHEME_AGENCY_ID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTENT sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-PARTNUMBERID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTROLLER sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-SCHEME_ID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-SCHEME_AGENCY_ID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-CONTENT sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-SERIALID sy-vline
WA_ISU_PODMEASTASK005R_MEASTASK_STR-SMARTMETERCAPABILITIES sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.