ABAP Select data from SAP table ISTRDCMPLNCLICPRODUCTTP4 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISTRDCMPLNCLICPRODUCTTP4 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISTRDCMPLNCLICPRODUCTTP4. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ISTRDCMPLNCLICPRODUCTTP4 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ISTRDCMPLNCLICPRODUCTTP4 TYPE STANDARD TABLE OF ISTRDCMPLNCLICPRODUCTTP4,
      WA_ISTRDCMPLNCLICPRODUCTTP4 TYPE ISTRDCMPLNCLICPRODUCTTP4,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ISTRDCMPLNCLICPRODUCTTP4> TYPE ISTRDCMPLNCLICPRODUCTTP4.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ISTRDCMPLNCLICPRODUCTTP4.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ISTRDCMPLNCLICPRODUCTTP4
  INTO TABLE IT_ISTRDCMPLNCLICPRODUCTTP4.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ISTRDCMPLNCLICPRODUCTTP4
*  INTO TABLE @DATA(IT_ISTRDCMPLNCLICPRODUCTTP42).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ISTRDCMPLNCLICPRODUCTTP4 INDEX 1 INTO DATA(WA_ISTRDCMPLNCLICPRODUCTTP42).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ISTRDCMPLNCLICPRODUCTTP4 ASSIGNING <ISTRDCMPLNCLICPRODUCTTP4>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISTRDCMPLNCLICPRODUCTTP4>-KEY = 1.
<ISTRDCMPLNCLICPRODUCTTP4>-PARENT_KEY = 1.
<ISTRDCMPLNCLICPRODUCTTP4>-ROOT_KEY = 1.
<ISTRDCMPLNCLICPRODUCTTP4>-PRODUCT = 1.
<ISTRDCMPLNCLICPRODUCTTP4>-TRDCMPLNCLICENSEMAXAMOUNT = 1.
ENDLOOP.

LOOP AT IT_ISTRDCMPLNCLICPRODUCTTP4 INTO WA_ISTRDCMPLNCLICPRODUCTTP4.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ISTRDCMPLNCLICPRODUCTTP4-TRDCMPLNCLICENSEDEPRCURRENCY, sy-vline,
WA_ISTRDCMPLNCLICPRODUCTTP4-TRDCMPLNCLICENSEAMTEXCDPCT, sy-vline,
WA_ISTRDCMPLNCLICPRODUCTTP4-TRDCMPLNCLICENSEMAXQUANTITY, sy-vline,
WA_ISTRDCMPLNCLICPRODUCTTP4-TRDCMPLNCLICENSEDEPRUNIT, sy-vline,
WA_ISTRDCMPLNCLICPRODUCTTP4-TRDCMPLNCLICENSEQTYEXCDPCT, sy-vline,
WA_ISTRDCMPLNCLICPRODUCTTP4-TRDCMPLNCLICMAXAMTISPROD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISTRDCMPLNCLICPRODUCTTP4 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISTRDCMPLNCLICPRODUCTTP4 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISTRDCMPLNCLICPRODUCTTP4 INTO WA_ISTRDCMPLNCLICPRODUCTTP4. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field PRODUCT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ISTRDCMPLNCLICPRODUCTTP4-PRODUCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISTRDCMPLNCLICPRODUCTTP4-PRODUCT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field TRDCMPLNCLICENSEDEPRUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ISTRDCMPLNCLICPRODUCTTP4-TRDCMPLNCLICENSEDEPRUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISTRDCMPLNCLICPRODUCTTP4-TRDCMPLNCLICENSEDEPRUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISTRDCMPLNCLICPRODUCTTP4_STR,
KEY TYPE STRING,
PARENT_KEY TYPE STRING,
ROOT_KEY TYPE STRING,
PRODUCT TYPE STRING,
TRDCMPLNCLICENSEMAXAMOUNT TYPE STRING,
TRDCMPLNCLICENSEDEPRCURRENCY TYPE STRING,
TRDCMPLNCLICENSEAMTEXCDPCT TYPE STRING,
TRDCMPLNCLICENSEMAXQUANTITY TYPE STRING,
TRDCMPLNCLICENSEDEPRUNIT TYPE STRING,
TRDCMPLNCLICENSEQTYEXCDPCT TYPE STRING,
TRDCMPLNCLICMAXAMTISPROD TYPE STRING,
TRDCMPLNCLICMAXQTYISPROD TYPE STRING,
ACTIVEUUID TYPE STRING,
HASACTIVEENTITY TYPE STRING,
DRAFTENTITYCREATIONDATETIME TYPE STRING,
DRAFTENTITYLASTCHANGEDATETIME TYPE STRING,
DRAFTADMINISTRATIVEDATAUUID TYPE STRING,
DRAFTENTITYCONSISTENCYSTATUS TYPE STRING,
DRAFTENTITYOPERATIONCODE TYPE STRING,
ISACTIVEENTITY TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISTRDCMPLNCLICPRODUCTTP4_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-KEY sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-PARENT_KEY sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-ROOT_KEY sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-PRODUCT sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-TRDCMPLNCLICENSEMAXAMOUNT sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-TRDCMPLNCLICENSEDEPRCURRENCY sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-TRDCMPLNCLICENSEAMTEXCDPCT sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-TRDCMPLNCLICENSEMAXQUANTITY sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-TRDCMPLNCLICENSEDEPRUNIT sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-TRDCMPLNCLICENSEQTYEXCDPCT sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-TRDCMPLNCLICMAXAMTISPROD sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-TRDCMPLNCLICMAXQTYISPROD sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-ACTIVEUUID sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-HASACTIVEENTITY sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-DRAFTENTITYCREATIONDATETIME sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-DRAFTENTITYLASTCHANGEDATETIME sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-DRAFTADMINISTRATIVEDATAUUID sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-DRAFTENTITYCONSISTENCYSTATUS sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-DRAFTENTITYOPERATIONCODE sy-vline
WA_ISTRDCMPLNCLICPRODUCTTP4_STR-ISACTIVEENTITY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.