ABAP Select data from SAP table ISSAFETYRELEVANTCHGAFFCDOBJTP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISSAFETYRELEVANTCHGAFFCDOBJTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISSAFETYRELEVANTCHGAFFCDOBJTP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ISSAFETYRELEVANTCHGAFFCDOBJTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ISSAFETYRELEVANTCHGAFFCDOBJTP TYPE STANDARD TABLE OF ISSAFETYRELEVANTCHGAFFCDOBJTP,
      WA_ISSAFETYRELEVANTCHGAFFCDOBJTP TYPE ISSAFETYRELEVANTCHGAFFCDOBJTP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ISSAFETYRELEVANTCHGAFFCDOBJTP> TYPE ISSAFETYRELEVANTCHGAFFCDOBJTP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ISSAFETYRELEVANTCHGAFFCDOBJTP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ISSAFETYRELEVANTCHGAFFCDOBJTP
  INTO TABLE IT_ISSAFETYRELEVANTCHGAFFCDOBJTP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ISSAFETYRELEVANTCHGAFFCDOBJTP
*  INTO TABLE @DATA(IT_ISSAFETYRELEVANTCHGAFFCDOBJTP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ISSAFETYRELEVANTCHGAFFCDOBJTP INDEX 1 INTO DATA(WA_ISSAFETYRELEVANTCHGAFFCDOBJTP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ISSAFETYRELEVANTCHGAFFCDOBJTP ASSIGNING <ISSAFETYRELEVANTCHGAFFCDOBJTP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISSAFETYRELEVANTCHGAFFCDOBJTP>-KEY = 1.
<ISSAFETYRELEVANTCHGAFFCDOBJTP>-PARENT_KEY = 1.
<ISSAFETYRELEVANTCHGAFFCDOBJTP>-ROOT_KEY = 1.
<ISSAFETYRELEVANTCHGAFFCDOBJTP>-SAFETYRELEVANTCHGAFFCDOBJTYPE = 1.
<ISSAFETYRELEVANTCHGAFFCDOBJTP>-SAFETYRELEVANTCHGNOTIFPROCGSTS = 1.
ENDLOOP.

LOOP AT IT_ISSAFETYRELEVANTCHGAFFCDOBJTP INTO WA_ISSAFETYRELEVANTCHGAFFCDOBJTP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ISSAFETYRELEVANTCHGAFFCDOBJTP-SAFETYRELEVANTCHANGENOTIFCMNT, sy-vline,
WA_ISSAFETYRELEVANTCHGAFFCDOBJTP-SAFETYRELEVANTCHGNOTIFPROCGUSR, sy-vline,
WA_ISSAFETYRELEVANTCHGAFFCDOBJTP-SAFETYRELEVANTCHGNOTIFPROCGDTE, sy-vline,
WA_ISSAFETYRELEVANTCHGAFFCDOBJTP-HZDSSUBSTINVENTORYUUID, sy-vline,
WA_ISSAFETYRELEVANTCHGAFFCDOBJTP-SAFETYINSTRUCTIONUUID, sy-vline,
WA_ISSAFETYRELEVANTCHGAFFCDOBJTP-EHSRISKASSESSMENTUUID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISSAFETYRELEVANTCHGAFFCDOBJTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISSAFETYRELEVANTCHGAFFCDOBJTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISSAFETYRELEVANTCHGAFFCDOBJTP INTO WA_ISSAFETYRELEVANTCHGAFFCDOBJTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISSAFETYRELEVANTCHGAFFCDOBJTP_STR,
KEY TYPE STRING,
PARENT_KEY TYPE STRING,
ROOT_KEY TYPE STRING,
SAFETYRELEVANTCHGAFFCDOBJTYPE TYPE STRING,
SAFETYRELEVANTCHGNOTIFPROCGSTS TYPE STRING,
SAFETYRELEVANTCHANGENOTIFCMNT TYPE STRING,
SAFETYRELEVANTCHGNOTIFPROCGUSR TYPE STRING,
SAFETYRELEVANTCHGNOTIFPROCGDTE TYPE STRING,
HZDSSUBSTINVENTORYUUID TYPE STRING,
SAFETYINSTRUCTIONUUID TYPE STRING,
EHSRISKASSESSMENTUUID TYPE STRING,
CHEMICALAPPROVALUUID TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISSAFETYRELEVANTCHGAFFCDOBJTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISSAFETYRELEVANTCHGAFFCDOBJTP_STR-KEY sy-vline
WA_ISSAFETYRELEVANTCHGAFFCDOBJTP_STR-PARENT_KEY sy-vline
WA_ISSAFETYRELEVANTCHGAFFCDOBJTP_STR-ROOT_KEY sy-vline
WA_ISSAFETYRELEVANTCHGAFFCDOBJTP_STR-SAFETYRELEVANTCHGAFFCDOBJTYPE sy-vline
WA_ISSAFETYRELEVANTCHGAFFCDOBJTP_STR-SAFETYRELEVANTCHGNOTIFPROCGSTS sy-vline
WA_ISSAFETYRELEVANTCHGAFFCDOBJTP_STR-SAFETYRELEVANTCHANGENOTIFCMNT sy-vline
WA_ISSAFETYRELEVANTCHGAFFCDOBJTP_STR-SAFETYRELEVANTCHGNOTIFPROCGUSR sy-vline
WA_ISSAFETYRELEVANTCHGAFFCDOBJTP_STR-SAFETYRELEVANTCHGNOTIFPROCGDTE sy-vline
WA_ISSAFETYRELEVANTCHGAFFCDOBJTP_STR-HZDSSUBSTINVENTORYUUID sy-vline
WA_ISSAFETYRELEVANTCHGAFFCDOBJTP_STR-SAFETYINSTRUCTIONUUID sy-vline
WA_ISSAFETYRELEVANTCHGAFFCDOBJTP_STR-EHSRISKASSESSMENTUUID sy-vline
WA_ISSAFETYRELEVANTCHGAFFCDOBJTP_STR-CHEMICALAPPROVALUUID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.