ABAP Select data from SAP table ISSAFETYINSTRUCTIONTP1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISSAFETYINSTRUCTIONTP1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISSAFETYINSTRUCTIONTP1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ISSAFETYINSTRUCTIONTP1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ISSAFETYINSTRUCTIONTP1 TYPE STANDARD TABLE OF ISSAFETYINSTRUCTIONTP1,
      WA_ISSAFETYINSTRUCTIONTP1 TYPE ISSAFETYINSTRUCTIONTP1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ISSAFETYINSTRUCTIONTP1> TYPE ISSAFETYINSTRUCTIONTP1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ISSAFETYINSTRUCTIONTP1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ISSAFETYINSTRUCTIONTP1
  INTO TABLE IT_ISSAFETYINSTRUCTIONTP1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ISSAFETYINSTRUCTIONTP1
*  INTO TABLE @DATA(IT_ISSAFETYINSTRUCTIONTP12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ISSAFETYINSTRUCTIONTP1 INDEX 1 INTO DATA(WA_ISSAFETYINSTRUCTIONTP12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ISSAFETYINSTRUCTIONTP1 ASSIGNING <ISSAFETYINSTRUCTIONTP1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISSAFETYINSTRUCTIONTP1>-KEY = 1.
<ISSAFETYINSTRUCTIONTP1>-PARENT_KEY = 1.
<ISSAFETYINSTRUCTIONTP1>-ROOT_KEY = 1.
<ISSAFETYINSTRUCTIONTP1>-SAFETYINSTRUCTION = 1.
<ISSAFETYINSTRUCTIONTP1>-SAFETYINSTRUCTIONSTATUS = 1.
ENDLOOP.

LOOP AT IT_ISSAFETYINSTRUCTIONTP1 INTO WA_ISSAFETYINSTRUCTIONTP1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ISSAFETYINSTRUCTIONTP1-SAFETYINSTRUCTIONMAJORREVISION, sy-vline,
WA_ISSAFETYINSTRUCTIONTP1-SAFETYINSTRUCTIONMINORREVISION, sy-vline,
WA_ISSAFETYINSTRUCTIONTP1-FACTORYEHSLOCATIONUUID, sy-vline,
WA_ISSAFETYINSTRUCTIONTP1-CHEMICALUUID, sy-vline,
WA_ISSAFETYINSTRUCTIONTP1-CHMLCMPLNCINFOUUID, sy-vline,
WA_ISSAFETYINSTRUCTIONTP1-JOBFREETEXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISSAFETYINSTRUCTIONTP1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISSAFETYINSTRUCTIONTP1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISSAFETYINSTRUCTIONTP1 INTO WA_ISSAFETYINSTRUCTIONTP1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SAFETYINSTRUCTION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISSAFETYINSTRUCTIONTP1-SAFETYINSTRUCTION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISSAFETYINSTRUCTIONTP1-SAFETYINSTRUCTION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGUAGE CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_ISSAFETYINSTRUCTIONTP1-LANGUAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISSAFETYINSTRUCTIONTP1-LANGUAGE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISSAFETYINSTRUCTIONTP1_STR,
KEY TYPE STRING,
PARENT_KEY TYPE STRING,
ROOT_KEY TYPE STRING,
SAFETYINSTRUCTION TYPE STRING,
SAFETYINSTRUCTIONSTATUS TYPE STRING,
SAFETYINSTRUCTIONMAJORREVISION TYPE STRING,
SAFETYINSTRUCTIONMINORREVISION TYPE STRING,
FACTORYEHSLOCATIONUUID TYPE STRING,
CHEMICALUUID TYPE STRING,
CHMLCMPLNCINFOUUID TYPE STRING,
JOBFREETEXT TYPE STRING,
FACTORYAREAFREETEXT TYPE STRING,
LANGUAGE TYPE STRING,
CREATIONUTCDATETIME TYPE STRING,
CREATEDBYUSER TYPE STRING,
SAFETYINSTRUCTIONRELDATE TYPE STRING,
RELEASEDBYUSER TYPE STRING,
LASTCHANGEUTCDATETIME TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
SAFETYINSTRUCTIONTYPE TYPE STRING,
SAFETYINSTRUCTIONSUBTYPE TYPE STRING,
SAFETYINSTRUCTIONSUBJECTDESC TYPE STRING,
SAFETYINSTRUCTIONISTEMPLATE TYPE STRING,
SAFETYINSTRUCTIONNOTE TYPE STRING,
SFTYINSTRNMIGRATIONSOURCE TYPE STRING,
ACTIVEUUID TYPE STRING,
HASACTIVEENTITY TYPE STRING,
DRAFTENTITYCREATIONDATETIME TYPE STRING,
DRAFTENTITYLASTCHANGEDATETIME TYPE STRING,
DRAFTADMINISTRATIVEDATAUUID TYPE STRING,
DRAFTENTITYCONSISTENCYSTATUS TYPE STRING,
DRAFTENTITYOPERATIONCODE TYPE STRING,
ISACTIVEENTITY TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISSAFETYINSTRUCTIONTP1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-KEY sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-PARENT_KEY sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-ROOT_KEY sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-SAFETYINSTRUCTION sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-SAFETYINSTRUCTIONSTATUS sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-SAFETYINSTRUCTIONMAJORREVISION sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-SAFETYINSTRUCTIONMINORREVISION sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-FACTORYEHSLOCATIONUUID sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-CHEMICALUUID sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-CHMLCMPLNCINFOUUID sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-JOBFREETEXT sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-FACTORYAREAFREETEXT sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-LANGUAGE sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-CREATIONUTCDATETIME sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-CREATEDBYUSER sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-SAFETYINSTRUCTIONRELDATE sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-RELEASEDBYUSER sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-LASTCHANGEUTCDATETIME sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-LASTCHANGEDBYUSER sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-SAFETYINSTRUCTIONTYPE sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-SAFETYINSTRUCTIONSUBTYPE sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-SAFETYINSTRUCTIONSUBJECTDESC sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-SAFETYINSTRUCTIONISTEMPLATE sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-SAFETYINSTRUCTIONNOTE sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-SFTYINSTRNMIGRATIONSOURCE sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-ACTIVEUUID sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-HASACTIVEENTITY sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-DRAFTENTITYCREATIONDATETIME sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-DRAFTENTITYLASTCHANGEDATETIME sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-DRAFTADMINISTRATIVEDATAUUID sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-DRAFTENTITYCONSISTENCYSTATUS sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-DRAFTENTITYOPERATIONCODE sy-vline
WA_ISSAFETYINSTRUCTIONTP1_STR-ISACTIVEENTITY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.