ABAP Select data from SAP table ISPROCCATALOGCALLDETAILSTTP_D into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISPROCCATALOGCALLDETAILSTTP_D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISPROCCATALOGCALLDETAILSTTP_D. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ISPROCCATALOGCALLDETAILSTTP_D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ISPROCCATALOGCALLDETAILSTTP_D TYPE STANDARD TABLE OF ISPROCCATALOGCALLDETAILSTTP_D,
      WA_ISPROCCATALOGCALLDETAILSTTP_D TYPE ISPROCCATALOGCALLDETAILSTTP_D,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ISPROCCATALOGCALLDETAILSTTP_D> TYPE ISPROCCATALOGCALLDETAILSTTP_D.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ISPROCCATALOGCALLDETAILSTTP_D.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ISPROCCATALOGCALLDETAILSTTP_D
  INTO TABLE IT_ISPROCCATALOGCALLDETAILSTTP_D.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ISPROCCATALOGCALLDETAILSTTP_D
*  INTO TABLE @DATA(IT_ISPROCCATALOGCALLDETAILSTTP_D2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ISPROCCATALOGCALLDETAILSTTP_D INDEX 1 INTO DATA(WA_ISPROCCATALOGCALLDETAILSTTP_D2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ISPROCCATALOGCALLDETAILSTTP_D ASSIGNING <ISPROCCATALOGCALLDETAILSTTP_D>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISPROCCATALOGCALLDETAILSTTP_D>-OPNCTLGWEBSERVICEID = 1.
<ISPROCCATALOGCALLDETAILSTTP_D>-OPNCTLGWEBSERVICEIDFOREDIT = 1.
<ISPROCCATALOGCALLDETAILSTTP_D>-OPNCTLGWEBSERVICENAME = 1.
<ISPROCCATALOGCALLDETAILSTTP_D>-ISDEFAULTCATALOG = 1.
<ISPROCCATALOGCALLDETAILSTTP_D>-OPNCTLGISPRODDSPALLWD = 1.
ENDLOOP.

LOOP AT IT_ISPROCCATALOGCALLDETAILSTTP_D INTO WA_ISPROCCATALOGCALLDETAILSTTP_D.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ISPROCCATALOGCALLDETAILSTTP_D-OPNCTLGISPRODUPDTALLWD, sy-vline,
WA_ISPROCCATALOGCALLDETAILSTTP_D-OPNCTLGISSRCGALLWD, sy-vline,
WA_ISPROCCATALOGCALLDETAILSTTP_D-OPNCTLGHASCRSCTLGSRCH, sy-vline,
WA_ISPROCCATALOGCALLDETAILSTTP_D-OPNCTLGHASPARTDETS, sy-vline,
WA_ISPROCCATALOGCALLDETAILSTTP_D-OPNCTLGHASHTTPGET, sy-vline,
WA_ISPROCCATALOGCALLDETAILSTTP_D-OPNCTLGICONPATH, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISPROCCATALOGCALLDETAILSTTP_D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISPROCCATALOGCALLDETAILSTTP_D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISPROCCATALOGCALLDETAILSTTP_D INTO WA_ISPROCCATALOGCALLDETAILSTTP_D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISPROCCATALOGCALLDETAILSTTP_D_STR,
OPNCTLGWEBSERVICEID TYPE STRING,
OPNCTLGWEBSERVICEIDFOREDIT TYPE STRING,
OPNCTLGWEBSERVICENAME TYPE STRING,
ISDEFAULTCATALOG TYPE STRING,
OPNCTLGISPRODDSPALLWD TYPE STRING,
OPNCTLGISPRODUPDTALLWD TYPE STRING,
OPNCTLGISSRCGALLWD TYPE STRING,
OPNCTLGHASCRSCTLGSRCH TYPE STRING,
OPNCTLGHASPARTDETS TYPE STRING,
OPNCTLGHASHTTPGET TYPE STRING,
OPNCTLGICONPATH TYPE STRING,
HASACTIVEENTITY TYPE STRING,
ISOPNCTLGPUNCHOUTDISABLED TYPE STRING,
ISOPNCTLGEXTRACTIONENABLED TYPE STRING,
ISERRORMSGNOTTOBELOGGED TYPE STRING,
ISSUCCESSMSGNOTTOBELOGGED TYPE STRING,
ISWARNINGMSGNOTTOBELOGGED TYPE STRING,
ISACTIVEENTITY TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISPROCCATALOGCALLDETAILSTTP_D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISPROCCATALOGCALLDETAILSTTP_D_STR-OPNCTLGWEBSERVICEID sy-vline
WA_ISPROCCATALOGCALLDETAILSTTP_D_STR-OPNCTLGWEBSERVICEIDFOREDIT sy-vline
WA_ISPROCCATALOGCALLDETAILSTTP_D_STR-OPNCTLGWEBSERVICENAME sy-vline
WA_ISPROCCATALOGCALLDETAILSTTP_D_STR-ISDEFAULTCATALOG sy-vline
WA_ISPROCCATALOGCALLDETAILSTTP_D_STR-OPNCTLGISPRODDSPALLWD sy-vline
WA_ISPROCCATALOGCALLDETAILSTTP_D_STR-OPNCTLGISPRODUPDTALLWD sy-vline
WA_ISPROCCATALOGCALLDETAILSTTP_D_STR-OPNCTLGISSRCGALLWD sy-vline
WA_ISPROCCATALOGCALLDETAILSTTP_D_STR-OPNCTLGHASCRSCTLGSRCH sy-vline
WA_ISPROCCATALOGCALLDETAILSTTP_D_STR-OPNCTLGHASPARTDETS sy-vline
WA_ISPROCCATALOGCALLDETAILSTTP_D_STR-OPNCTLGHASHTTPGET sy-vline
WA_ISPROCCATALOGCALLDETAILSTTP_D_STR-OPNCTLGICONPATH sy-vline
WA_ISPROCCATALOGCALLDETAILSTTP_D_STR-HASACTIVEENTITY sy-vline
WA_ISPROCCATALOGCALLDETAILSTTP_D_STR-ISOPNCTLGPUNCHOUTDISABLED sy-vline
WA_ISPROCCATALOGCALLDETAILSTTP_D_STR-ISOPNCTLGEXTRACTIONENABLED sy-vline
WA_ISPROCCATALOGCALLDETAILSTTP_D_STR-ISERRORMSGNOTTOBELOGGED sy-vline
WA_ISPROCCATALOGCALLDETAILSTTP_D_STR-ISSUCCESSMSGNOTTOBELOGGED sy-vline
WA_ISPROCCATALOGCALLDETAILSTTP_D_STR-ISWARNINGMSGNOTTOBELOGGED sy-vline
WA_ISPROCCATALOGCALLDETAILSTTP_D_STR-ISACTIVEENTITY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.