ABAP Select data from SAP table ISPHYSCHMLVISCOSITYDYNTP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISPHYSCHMLVISCOSITYDYNTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISPHYSCHMLVISCOSITYDYNTP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ISPHYSCHMLVISCOSITYDYNTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ISPHYSCHMLVISCOSITYDYNTP TYPE STANDARD TABLE OF ISPHYSCHMLVISCOSITYDYNTP,
      WA_ISPHYSCHMLVISCOSITYDYNTP TYPE ISPHYSCHMLVISCOSITYDYNTP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ISPHYSCHMLVISCOSITYDYNTP> TYPE ISPHYSCHMLVISCOSITYDYNTP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ISPHYSCHMLVISCOSITYDYNTP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ISPHYSCHMLVISCOSITYDYNTP
  INTO TABLE IT_ISPHYSCHMLVISCOSITYDYNTP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ISPHYSCHMLVISCOSITYDYNTP
*  INTO TABLE @DATA(IT_ISPHYSCHMLVISCOSITYDYNTP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ISPHYSCHMLVISCOSITYDYNTP INDEX 1 INTO DATA(WA_ISPHYSCHMLVISCOSITYDYNTP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ISPHYSCHMLVISCOSITYDYNTP ASSIGNING <ISPHYSCHMLVISCOSITYDYNTP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISPHYSCHMLVISCOSITYDYNTP>-KEY = 1.
<ISPHYSCHMLVISCOSITYDYNTP>-PARENT_KEY = 1.
<ISPHYSCHMLVISCOSITYDYNTP>-ROOT_KEY = 1.
<ISPHYSCHMLVISCOSITYDYNTP>-CREATIONUTCDATETIME = 1.
<ISPHYSCHMLVISCOSITYDYNTP>-CREATEDBYUSER = 1.
ENDLOOP.

LOOP AT IT_ISPHYSCHMLVISCOSITYDYNTP INTO WA_ISPHYSCHMLVISCOSITYDYNTP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ISPHYSCHMLVISCOSITYDYNTP-LASTCHANGEUTCDATETIME, sy-vline,
WA_ISPHYSCHMLVISCOSITYDYNTP-LASTCHANGEDBYUSER, sy-vline,
WA_ISPHYSCHMLVISCOSITYDYNTP-PCPRPTYLOWRLMTOPTR, sy-vline,
WA_ISPHYSCHMLVISCOSITYDYNTP-PHYSCHMLVISCOSITYDYNLOWRQTY, sy-vline,
WA_ISPHYSCHMLVISCOSITYDYNTP-PHYSCHMLVISCOSITYDYNLOWRQTYTXT, sy-vline,
WA_ISPHYSCHMLVISCOSITYDYNTP-PCPRPTYUPRLMTOPTR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISPHYSCHMLVISCOSITYDYNTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISPHYSCHMLVISCOSITYDYNTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISPHYSCHMLVISCOSITYDYNTP INTO WA_ISPHYSCHMLVISCOSITYDYNTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field PHYSCHMLVISCOSITYDYNQTYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ISPHYSCHMLVISCOSITYDYNTP-PHYSCHMLVISCOSITYDYNQTYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISPHYSCHMLVISCOSITYDYNTP-PHYSCHMLVISCOSITYDYNQTYUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISPHYSCHMLVISCOSITYDYNTP_STR,
KEY TYPE STRING,
PARENT_KEY TYPE STRING,
ROOT_KEY TYPE STRING,
CREATIONUTCDATETIME TYPE STRING,
CREATEDBYUSER TYPE STRING,
LASTCHANGEUTCDATETIME TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
PCPRPTYLOWRLMTOPTR TYPE STRING,
PHYSCHMLVISCOSITYDYNLOWRQTY TYPE STRING,
PHYSCHMLVISCOSITYDYNLOWRQTYTXT TYPE STRING,
PCPRPTYUPRLMTOPTR TYPE STRING,
PHYSCHMLVISCOSITYDYNUPRQTY TYPE STRING,
PHYSCHMLVISCOSITYDYNUPRQTYTXT TYPE STRING,
PHYSCHMLVISCOSITYDYNQTYUNIT TYPE STRING,
PCPHYSNOTETEXT TYPE STRING,
PCPHYSADDLSTATEMENTPHRSUUID TYPE STRING,
ACTIVEUUID TYPE STRING,
HASACTIVEENTITY TYPE STRING,
DRAFTENTITYCREATIONDATETIME TYPE STRING,
DRAFTENTITYLASTCHANGEDATETIME TYPE STRING,
DRAFTADMINISTRATIVEDATAUUID TYPE STRING,
DRAFTENTITYCONSISTENCYSTATUS TYPE STRING,
DRAFTENTITYOPERATIONCODE TYPE STRING,
ISACTIVEENTITY TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISPHYSCHMLVISCOSITYDYNTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-KEY sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-PARENT_KEY sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-ROOT_KEY sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-CREATIONUTCDATETIME sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-CREATEDBYUSER sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-LASTCHANGEUTCDATETIME sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-LASTCHANGEDBYUSER sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-PCPRPTYLOWRLMTOPTR sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-PHYSCHMLVISCOSITYDYNLOWRQTY sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-PHYSCHMLVISCOSITYDYNLOWRQTYTXT sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-PCPRPTYUPRLMTOPTR sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-PHYSCHMLVISCOSITYDYNUPRQTY sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-PHYSCHMLVISCOSITYDYNUPRQTYTXT sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-PHYSCHMLVISCOSITYDYNQTYUNIT sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-PCPHYSNOTETEXT sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-PCPHYSADDLSTATEMENTPHRSUUID sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-ACTIVEUUID sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-HASACTIVEENTITY sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-DRAFTENTITYCREATIONDATETIME sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-DRAFTENTITYLASTCHANGEDATETIME sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-DRAFTADMINISTRATIVEDATAUUID sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-DRAFTENTITYCONSISTENCYSTATUS sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-DRAFTENTITYOPERATIONCODE sy-vline
WA_ISPHYSCHMLVISCOSITYDYNTP_STR-ISACTIVEENTITY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.