ABAP Select data from SAP table ISPCSFTYFLASHPOINTTP_D into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISPCSFTYFLASHPOINTTP_D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISPCSFTYFLASHPOINTTP_D. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ISPCSFTYFLASHPOINTTP_D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ISPCSFTYFLASHPOINTTP_D TYPE STANDARD TABLE OF ISPCSFTYFLASHPOINTTP_D,
      WA_ISPCSFTYFLASHPOINTTP_D TYPE ISPCSFTYFLASHPOINTTP_D,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ISPCSFTYFLASHPOINTTP_D> TYPE ISPCSFTYFLASHPOINTTP_D.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ISPCSFTYFLASHPOINTTP_D.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ISPCSFTYFLASHPOINTTP_D
  INTO TABLE IT_ISPCSFTYFLASHPOINTTP_D.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ISPCSFTYFLASHPOINTTP_D
*  INTO TABLE @DATA(IT_ISPCSFTYFLASHPOINTTP_D2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ISPCSFTYFLASHPOINTTP_D INDEX 1 INTO DATA(WA_ISPCSFTYFLASHPOINTTP_D2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ISPCSFTYFLASHPOINTTP_D ASSIGNING <ISPCSFTYFLASHPOINTTP_D>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISPCSFTYFLASHPOINTTP_D>-CREATIONUTCDATETIME = 1.
<ISPCSFTYFLASHPOINTTP_D>-CREATEDBYUSER = 1.
<ISPCSFTYFLASHPOINTTP_D>-LASTCHANGEUTCDATETIME = 1.
<ISPCSFTYFLASHPOINTTP_D>-LASTCHANGEDBYUSER = 1.
<ISPCSFTYFLASHPOINTTP_D>-PCSFTYFLASHPTOPNCUPLOWROPTR = 1.
ENDLOOP.

LOOP AT IT_ISPCSFTYFLASHPOINTTP_D INTO WA_ISPCSFTYFLASHPOINTTP_D.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ISPCSFTYFLASHPOINTTP_D-PCSFTYFLASHPTOPNCUPLOWRQTY, sy-vline,
WA_ISPCSFTYFLASHPOINTTP_D-PCSFTYFLASHPTOPNCUPLOWRQTYTXT, sy-vline,
WA_ISPCSFTYFLASHPOINTTP_D-PCSFTYFLASHPTOPNCUPUPROPTR, sy-vline,
WA_ISPCSFTYFLASHPOINTTP_D-PCSFTYFLASHPTOPNCUPUPRQTY, sy-vline,
WA_ISPCSFTYFLASHPOINTTP_D-PCSFTYFLASHPTOPNCUPUPRQTYTXT, sy-vline,
WA_ISPCSFTYFLASHPOINTTP_D-PCSFTYFLASHPTOPNCUPPHRSUUID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISPCSFTYFLASHPOINTTP_D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISPCSFTYFLASHPOINTTP_D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISPCSFTYFLASHPOINTTP_D INTO WA_ISPCSFTYFLASHPOINTTP_D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field PCSFTYFLASHPTQTYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ISPCSFTYFLASHPOINTTP_D-PCSFTYFLASHPTQTYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISPCSFTYFLASHPOINTTP_D-PCSFTYFLASHPTQTYUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISPCSFTYFLASHPOINTTP_D_STR,
CREATIONUTCDATETIME TYPE STRING,
CREATEDBYUSER TYPE STRING,
LASTCHANGEUTCDATETIME TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
PCSFTYFLASHPTOPNCUPLOWROPTR TYPE STRING,
PCSFTYFLASHPTOPNCUPLOWRQTY TYPE STRING,
PCSFTYFLASHPTOPNCUPLOWRQTYTXT TYPE STRING,
PCSFTYFLASHPTOPNCUPUPROPTR TYPE STRING,
PCSFTYFLASHPTOPNCUPUPRQTY TYPE STRING,
PCSFTYFLASHPTOPNCUPUPRQTYTXT TYPE STRING,
PCSFTYFLASHPTOPNCUPPHRSUUID TYPE STRING,
PCSFTYFLASHPTCLSDCUPLOWROPTR TYPE STRING,
PCSFTYFLASHPTCLSDCUPLOWRQTY TYPE STRING,
PCSFTYFLASHPTCLSDCUPLOWRQTYTXT TYPE STRING,
PCSFTYFLASHPTCLSDCUPUPROPTR TYPE STRING,
PCSFTYFLASHPTCLSDCUPUPRQTY TYPE STRING,
PCSFTYFLASHPTCLSDCUPUPRQTYTXT TYPE STRING,
PCSFTYFLASHPTCLSDCUPPHRSUUID TYPE STRING,
PCSFTYFLASHPTQTYUNIT TYPE STRING,
PCSFTYNOTETEXT TYPE STRING,
PCSFTYADDLSTATEMENTPHRSUUID TYPE STRING,
PCSFTYASSESSMENTPHRSUUID TYPE STRING,
PCSFTYHASNOAPPL TYPE STRING,
PCSFTYHASNODATA TYPE STRING,
ACTIVEUUID TYPE STRING,
HASACTIVEENTITY TYPE STRING,
DRAFTENTITYCREATIONDATETIME TYPE STRING,
DRAFTENTITYLASTCHANGEDATETIME TYPE STRING,
DRAFTADMINISTRATIVEDATAUUID TYPE STRING,
DRAFTENTITYCONSISTENCYSTATUS TYPE STRING,
DRAFTENTITYOPERATIONCODE TYPE STRING,
ISACTIVEENTITY TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISPCSFTYFLASHPOINTTP_D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-CREATIONUTCDATETIME sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-CREATEDBYUSER sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-LASTCHANGEUTCDATETIME sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-LASTCHANGEDBYUSER sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYFLASHPTOPNCUPLOWROPTR sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYFLASHPTOPNCUPLOWRQTY sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYFLASHPTOPNCUPLOWRQTYTXT sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYFLASHPTOPNCUPUPROPTR sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYFLASHPTOPNCUPUPRQTY sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYFLASHPTOPNCUPUPRQTYTXT sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYFLASHPTOPNCUPPHRSUUID sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYFLASHPTCLSDCUPLOWROPTR sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYFLASHPTCLSDCUPLOWRQTY sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYFLASHPTCLSDCUPLOWRQTYTXT sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYFLASHPTCLSDCUPUPROPTR sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYFLASHPTCLSDCUPUPRQTY sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYFLASHPTCLSDCUPUPRQTYTXT sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYFLASHPTCLSDCUPPHRSUUID sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYFLASHPTQTYUNIT sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYNOTETEXT sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYADDLSTATEMENTPHRSUUID sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYASSESSMENTPHRSUUID sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYHASNOAPPL sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-PCSFTYHASNODATA sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-ACTIVEUUID sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-HASACTIVEENTITY sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-DRAFTENTITYCREATIONDATETIME sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-DRAFTENTITYLASTCHANGEDATETIME sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-DRAFTADMINISTRATIVEDATAUUID sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-DRAFTENTITYCONSISTENCYSTATUS sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-DRAFTENTITYOPERATIONCODE sy-vline
WA_ISPCSFTYFLASHPOINTTP_D_STR-ISACTIVEENTITY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.