ABAP Select data from SAP table ISPCECTXSOILDWELLINGORGNSMT_DR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISPCECTXSOILDWELLINGORGNSMT_DR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISPCECTXSOILDWELLINGORGNSMT_DR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ISPCECTXSOILDWELLINGORGNSMT_DR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ISPCECTXSOILDWELLINGORGNSMT_DR TYPE STANDARD TABLE OF ISPCECTXSOILDWELLINGORGNSMT_DR,
      WA_ISPCECTXSOILDWELLINGORGNSMT_DR TYPE ISPCECTXSOILDWELLINGORGNSMT_DR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ISPCECTXSOILDWELLINGORGNSMT_DR> TYPE ISPCECTXSOILDWELLINGORGNSMT_DR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ISPCECTXSOILDWELLINGORGNSMT_DR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ISPCECTXSOILDWELLINGORGNSMT_DR
  INTO TABLE IT_ISPCECTXSOILDWELLINGORGNSMT_DR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ISPCECTXSOILDWELLINGORGNSMT_DR
*  INTO TABLE @DATA(IT_ISPCECTXSOILDWELLINGORGNSMT_DR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ISPCECTXSOILDWELLINGORGNSMT_DR INDEX 1 INTO DATA(WA_ISPCECTXSOILDWELLINGORGNSMT_DR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ISPCECTXSOILDWELLINGORGNSMT_DR ASSIGNING <ISPCECTXSOILDWELLINGORGNSMT_DR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISPCECTXSOILDWELLINGORGNSMT_DR>-PCECTXSOILORGNSMUUID = 1.
<ISPCECTXSOILDWELLINGORGNSMT_DR>-PCECTXPRPTYUUID = 1.
<ISPCECTXSOILDWELLINGORGNSMT_DR>-PCECTXSPECIESPHRSUUID = 1.
<ISPCECTXSOILDWELLINGORGNSMT_DR>-PCECTXEXPSRDURN = 1.
<ISPCECTXSOILDWELLINGORGNSMT_DR>-PCECTXEXPSRDURNASTEXT = 1.
ENDLOOP.

LOOP AT IT_ISPCECTXSOILDWELLINGORGNSMT_DR INTO WA_ISPCECTXSOILDWELLINGORGNSMT_DR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ISPCECTXSOILDWELLINGORGNSMT_DR-PCECTXEXPSRUOM, sy-vline,
WA_ISPCECTXSOILDWELLINGORGNSMT_DR-PCECTXVALUETYPEPHRSUUID, sy-vline,
WA_ISPCECTXSOILDWELLINGORGNSMT_DR-PCECTXVALUELOWRQTY, sy-vline,
WA_ISPCECTXSOILDWELLINGORGNSMT_DR-PCECTXVALUELOWRQTYTXT, sy-vline,
WA_ISPCECTXSOILDWELLINGORGNSMT_DR-PCECTXVALUELOWRQTYOPTR, sy-vline,
WA_ISPCECTXSOILDWELLINGORGNSMT_DR-PCECTXVALUEUPRQTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISPCECTXSOILDWELLINGORGNSMT_DR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISPCECTXSOILDWELLINGORGNSMT_DR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISPCECTXSOILDWELLINGORGNSMT_DR INTO WA_ISPCECTXSOILDWELLINGORGNSMT_DR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field PCECTXEXPSRUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ISPCECTXSOILDWELLINGORGNSMT_DR-PCECTXEXPSRUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISPCECTXSOILDWELLINGORGNSMT_DR-PCECTXEXPSRUOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PCECTXVALUEUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ISPCECTXSOILDWELLINGORGNSMT_DR-PCECTXVALUEUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISPCECTXSOILDWELLINGORGNSMT_DR-PCECTXVALUEUOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISPCECTXSOILDWELLINGORGNSMT_DR_STR,
PCECTXSOILORGNSMUUID TYPE STRING,
PCECTXPRPTYUUID TYPE STRING,
PCECTXSPECIESPHRSUUID TYPE STRING,
PCECTXEXPSRDURN TYPE STRING,
PCECTXEXPSRDURNASTEXT TYPE STRING,
PCECTXEXPSRUOM TYPE STRING,
PCECTXVALUETYPEPHRSUUID TYPE STRING,
PCECTXVALUELOWRQTY TYPE STRING,
PCECTXVALUELOWRQTYTXT TYPE STRING,
PCECTXVALUELOWRQTYOPTR TYPE STRING,
PCECTXVALUEUPRQTY TYPE STRING,
PCECTXVALUEUPRQTYTXT TYPE STRING,
PCECTXVALUEUPRQTYOPTR TYPE STRING,
PCECTXVALUEUOM TYPE STRING,
PCECTXMETHODPHRSUUID TYPE STRING,
PCECTXNOTETEXT TYPE STRING,
PCECTXRATING TYPE STRING,
PCECTXADDLSTATEMENTPHRSUUID TYPE STRING,
CREATIONUTCDATETIME TYPE STRING,
CREATEDBYUSER TYPE STRING,
LASTCHANGEUTCDATETIME TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
ACTIVEUUID TYPE STRING,
HASACTIVEENTITY TYPE STRING,
DRAFTENTITYCREATIONDATETIME TYPE STRING,
DRAFTENTITYLASTCHANGEDATETIME TYPE STRING,
DRAFTADMINISTRATIVEDATAUUID TYPE STRING,
DRAFTENTITYCONSISTENCYSTATUS TYPE STRING,
DRAFTENTITYOPERATIONCODE TYPE STRING,
ISACTIVEENTITY TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-PCECTXSOILORGNSMUUID sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-PCECTXPRPTYUUID sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-PCECTXSPECIESPHRSUUID sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-PCECTXEXPSRDURN sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-PCECTXEXPSRDURNASTEXT sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-PCECTXEXPSRUOM sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-PCECTXVALUETYPEPHRSUUID sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-PCECTXVALUELOWRQTY sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-PCECTXVALUELOWRQTYTXT sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-PCECTXVALUELOWRQTYOPTR sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-PCECTXVALUEUPRQTY sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-PCECTXVALUEUPRQTYTXT sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-PCECTXVALUEUPRQTYOPTR sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-PCECTXVALUEUOM sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-PCECTXMETHODPHRSUUID sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-PCECTXNOTETEXT sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-PCECTXRATING sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-PCECTXADDLSTATEMENTPHRSUUID sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-CREATIONUTCDATETIME sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-CREATEDBYUSER sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-LASTCHANGEUTCDATETIME sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-LASTCHANGEDBYUSER sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-ACTIVEUUID sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-HASACTIVEENTITY sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-DRAFTENTITYCREATIONDATETIME sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-DRAFTENTITYLASTCHANGEDATETIME sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-DRAFTADMINISTRATIVEDATAUUID sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-DRAFTENTITYCONSISTENCYSTATUS sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-DRAFTENTITYOPERATIONCODE sy-vline
WA_ISPCECTXSOILDWELLINGORGNSMT_DR_STR-ISACTIVEENTITY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.