ABAP Select data from SAP table ISINSPPLANOPERATIONTP_D into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISINSPPLANOPERATIONTP_D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISINSPPLANOPERATIONTP_D. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ISINSPPLANOPERATIONTP_D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ISINSPPLANOPERATIONTP_D TYPE STANDARD TABLE OF ISINSPPLANOPERATIONTP_D,
      WA_ISINSPPLANOPERATIONTP_D TYPE ISINSPPLANOPERATIONTP_D,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ISINSPPLANOPERATIONTP_D> TYPE ISINSPPLANOPERATIONTP_D.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ISINSPPLANOPERATIONTP_D.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ISINSPPLANOPERATIONTP_D
  INTO TABLE IT_ISINSPPLANOPERATIONTP_D.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ISINSPPLANOPERATIONTP_D
*  INTO TABLE @DATA(IT_ISINSPPLANOPERATIONTP_D2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ISINSPPLANOPERATIONTP_D INDEX 1 INTO DATA(WA_ISINSPPLANOPERATIONTP_D2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ISINSPPLANOPERATIONTP_D ASSIGNING <ISINSPPLANOPERATIONTP_D>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISINSPPLANOPERATIONTP_D>-INSPECTIONPLANGROUP = 1.
<ISINSPPLANOPERATIONTP_D>-INSPECTIONPLAN = 1.
<ISINSPPLANOPERATIONTP_D>-INSPECTIONPLANINTERNALVERSION = 1.
<ISINSPPLANOPERATIONTP_D>-BOOOPERATIONINTERNALID = 1.
<ISINSPPLANOPERATIONTP_D>-BOOOPINTERNALVERSIONCOUNTER = 1.
ENDLOOP.

LOOP AT IT_ISINSPPLANOPERATIONTP_D INTO WA_ISINSPPLANOPERATIONTP_D.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ISINSPPLANOPERATIONTP_D-BILLOFOPERATIONSTYPE, sy-vline,
WA_ISINSPPLANOPERATIONTP_D-BOOSQNCOPASSGMTINTVERSIONCNTR, sy-vline,
WA_ISINSPPLANOPERATIONTP_D-WORKCENTERINTERNALID, sy-vline,
WA_ISINSPPLANOPERATIONTP_D-WORKCENTERTYPECODE, sy-vline,
WA_ISINSPPLANOPERATIONTP_D-WORKCENTER, sy-vline,
WA_ISINSPPLANOPERATIONTP_D-ISDELETED, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISINSPPLANOPERATIONTP_D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISINSPPLANOPERATIONTP_D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISINSPPLANOPERATIONTP_D INTO WA_ISINSPPLANOPERATIONTP_D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INSPECTIONPLANGROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISINSPPLANOPERATIONTP_D-INSPECTIONPLANGROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISINSPPLANOPERATIONTP_D-INSPECTIONPLANGROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONPLAN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISINSPPLANOPERATIONTP_D-INSPECTIONPLAN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISINSPPLANOPERATIONTP_D-INSPECTIONPLAN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field OPERATION CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_ISINSPPLANOPERATIONTP_D-OPERATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISINSPPLANOPERATIONTP_D-OPERATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BILLOFOPERATIONSREFGROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISINSPPLANOPERATIONTP_D-BILLOFOPERATIONSREFGROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISINSPPLANOPERATIONTP_D-BILLOFOPERATIONSREFGROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BILLOFOPERATIONSREFVARIANT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISINSPPLANOPERATIONTP_D-BILLOFOPERATIONSREFVARIANT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISINSPPLANOPERATIONTP_D-BILLOFOPERATIONSREFVARIANT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field OPERATIONUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ISINSPPLANOPERATIONTP_D-OPERATIONUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISINSPPLANOPERATIONTP_D-OPERATIONUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CHANGENUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISINSPPLANOPERATIONTP_D-CHANGENUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISINSPPLANOPERATIONTP_D-CHANGENUMBER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISINSPPLANOPERATIONTP_D_STR,
INSPECTIONPLANGROUP TYPE STRING,
INSPECTIONPLAN TYPE STRING,
INSPECTIONPLANINTERNALVERSION TYPE STRING,
BOOOPERATIONINTERNALID TYPE STRING,
BOOOPINTERNALVERSIONCOUNTER TYPE STRING,
BILLOFOPERATIONSTYPE TYPE STRING,
BOOSQNCOPASSGMTINTVERSIONCNTR TYPE STRING,
WORKCENTERINTERNALID TYPE STRING,
WORKCENTERTYPECODE TYPE STRING,
WORKCENTER TYPE STRING,
ISDELETED TYPE STRING,
ISIMPLICITLYDELETED TYPE STRING,
OPERATIONEXTERNALID TYPE STRING,
OPERATION TYPE STRING,
OPERATIONTEXT TYPE STRING,
PLANT TYPE STRING,
OPERATIONCONTROLPROFILE TYPE STRING,
OPERATIONSTANDARDTEXTCODE TYPE STRING,
BILLOFOPERATIONSREFTYPE TYPE STRING,
BILLOFOPERATIONSREFGROUP TYPE STRING,
BILLOFOPERATIONSREFVARIANT TYPE STRING,
BOOREFOPERATIONINCREMENTVALUE TYPE STRING,
INSPRESULTRECORDINGVIEW TYPE STRING,
INSPSBSTCOMPLETIONCONFIRMATION TYPE STRING,
INSPSBSTHASNOTIMEORQUANTITY TYPE STRING,
OPERATIONREFERENCEQUANTITY TYPE STRING,
OPERATIONUNIT TYPE STRING,
OPQTYTOBASEQTYDNMNTR TYPE STRING,
OPQTYTOBASEQTYNMRTR TYPE STRING,
CREATIONDATE TYPE STRING,
CREATEDBYUSER TYPE STRING,
LASTCHANGEDATE TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
CHANGENUMBER TYPE STRING,
VALIDITYSTARTDATE TYPE STRING,
VALIDITYENDDATE TYPE STRING,
ISVALID TYPE STRING,
BILLOFOPERATIONSSTATUS TYPE STRING,
BILLOFOPERATIONSUSAGE TYPE STRING,
HASACTIVEENTITY TYPE STRING,
DRAFTENTITYCREATIONDATETIME TYPE STRING,
DRAFTENTITYLASTCHANGEDATETIME TYPE STRING,
DRAFTADMINISTRATIVEDATAUUID TYPE STRING,
DRAFTENTITYCONSISTENCYSTATUS TYPE STRING,
DRAFTENTITYOPERATIONCODE TYPE STRING,
ISACTIVEENTITY TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISINSPPLANOPERATIONTP_D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-INSPECTIONPLANGROUP sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-INSPECTIONPLAN sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-INSPECTIONPLANINTERNALVERSION sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-BOOOPERATIONINTERNALID sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-BOOOPINTERNALVERSIONCOUNTER sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-BILLOFOPERATIONSTYPE sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-BOOSQNCOPASSGMTINTVERSIONCNTR sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-WORKCENTERINTERNALID sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-WORKCENTERTYPECODE sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-WORKCENTER sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-ISDELETED sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-ISIMPLICITLYDELETED sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-OPERATIONEXTERNALID sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-OPERATION sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-OPERATIONTEXT sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-PLANT sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-OPERATIONCONTROLPROFILE sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-OPERATIONSTANDARDTEXTCODE sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-BILLOFOPERATIONSREFTYPE sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-BILLOFOPERATIONSREFGROUP sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-BILLOFOPERATIONSREFVARIANT sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-BOOREFOPERATIONINCREMENTVALUE sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-INSPRESULTRECORDINGVIEW sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-INSPSBSTCOMPLETIONCONFIRMATION sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-INSPSBSTHASNOTIMEORQUANTITY sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-OPERATIONREFERENCEQUANTITY sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-OPERATIONUNIT sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-OPQTYTOBASEQTYDNMNTR sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-OPQTYTOBASEQTYNMRTR sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-CREATIONDATE sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-CREATEDBYUSER sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-LASTCHANGEDATE sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-LASTCHANGEDBYUSER sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-CHANGENUMBER sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-VALIDITYSTARTDATE sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-VALIDITYENDDATE sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-ISVALID sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-BILLOFOPERATIONSSTATUS sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-BILLOFOPERATIONSUSAGE sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-HASACTIVEENTITY sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-DRAFTENTITYCREATIONDATETIME sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-DRAFTENTITYLASTCHANGEDATETIME sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-DRAFTADMINISTRATIVEDATAUUID sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-DRAFTENTITYCONSISTENCYSTATUS sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-DRAFTENTITYOPERATIONCODE sy-vline
WA_ISINSPPLANOPERATIONTP_D_STR-ISACTIVEENTITY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.