ABAP Select data from SAP table ISINCGFRMTNODETP3_D into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISINCGFRMTNODETP3_D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISINCGFRMTNODETP3_D. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ISINCGFRMTNODETP3_D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ISINCGFRMTNODETP3_D TYPE STANDARD TABLE OF ISINCGFRMTNODETP3_D,
      WA_ISINCGFRMTNODETP3_D TYPE ISINCGFRMTNODETP3_D,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ISINCGFRMTNODETP3_D> TYPE ISINCGFRMTNODETP3_D.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ISINCGFRMTNODETP3_D.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ISINCGFRMTNODETP3_D
  INTO TABLE IT_ISINCGFRMTNODETP3_D.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ISINCGFRMTNODETP3_D
*  INTO TABLE @DATA(IT_ISINCGFRMTNODETP3_D2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ISINCGFRMTNODETP3_D INDEX 1 INTO DATA(WA_ISINCGFRMTNODETP3_D2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ISINCGFRMTNODETP3_D ASSIGNING <ISINCGFRMTNODETP3_D>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISINCGFRMTNODETP3_D>-HIERARCHYTREETYPE = 1.
<ISINCGFRMTNODETP3_D>-HIERARCHYTREE = 1.
<ISINCGFRMTNODETP3_D>-HIERARCHYTREEVERSION = 1.
<ISINCGFRMTNODETP3_D>-HIERARCHYNODE = 1.
<ISINCGFRMTNODETP3_D>-HIERARCHYNODESTATUS = 1.
ENDLOOP.

LOOP AT IT_ISINCGFRMTNODETP3_D INTO WA_ISINCGFRMTNODETP3_D.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ISINCGFRMTNODETP3_D-PARENTNODE, sy-vline,
WA_ISINCGFRMTNODETP3_D-SIBLINGNODE, sy-vline,
WA_ISINCGFRMTNODETP3_D-CHILDNODE, sy-vline,
WA_ISINCGFRMTNODETP3_D-NODENAME, sy-vline,
WA_ISINCGFRMTNODETP3_D-NODETYPE, sy-vline,
WA_ISINCGFRMTNODETP3_D-HIERARCHYNODEISDEACTIVATED, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISINCGFRMTNODETP3_D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISINCGFRMTNODETP3_D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISINCGFRMTNODETP3_D INTO WA_ISINCGFRMTNODETP3_D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISINCGFRMTNODETP3_D_STR,
HIERARCHYTREETYPE TYPE STRING,
HIERARCHYTREE TYPE STRING,
HIERARCHYTREEVERSION TYPE STRING,
HIERARCHYNODE TYPE STRING,
HIERARCHYNODESTATUS TYPE STRING,
PARENTNODE TYPE STRING,
SIBLINGNODE TYPE STRING,
CHILDNODE TYPE STRING,
NODENAME TYPE STRING,
NODETYPE TYPE STRING,
HIERARCHYNODEISDEACTIVATED TYPE STRING,
HIERARCHYNODEREFERENCE TYPE STRING,
HIERARCHYNODESHORTTEXT TYPE STRING,
FIELDDELIMITERTYPE TYPE STRING,
FIELDDELIMITERVALUE TYPE STRING,
ENDOFLINEREPLACEMENTTYPE TYPE STRING,
ENDOFLINEREPLACEMENTVALUE TYPE STRING,
SOURCEVALUEOFFSET TYPE STRING,
SOURCEVALUELENGTH TYPE STRING,
CONTENTSTARTINGVALUE TYPE STRING,
CONTENTENDINGVALUE TYPE STRING,
HASACTIVEENTITY TYPE STRING,
DRAFTENTITYCREATIONDATETIME TYPE STRING,
DRAFTENTITYLASTCHANGEDATETIME TYPE STRING,
DRAFTADMINISTRATIVEDATAUUID TYPE STRING,
DRAFTENTITYCONSISTENCYSTATUS TYPE STRING,
DRAFTENTITYOPERATIONCODE TYPE STRING,
ISACTIVEENTITY TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISINCGFRMTNODETP3_D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISINCGFRMTNODETP3_D_STR-HIERARCHYTREETYPE sy-vline
WA_ISINCGFRMTNODETP3_D_STR-HIERARCHYTREE sy-vline
WA_ISINCGFRMTNODETP3_D_STR-HIERARCHYTREEVERSION sy-vline
WA_ISINCGFRMTNODETP3_D_STR-HIERARCHYNODE sy-vline
WA_ISINCGFRMTNODETP3_D_STR-HIERARCHYNODESTATUS sy-vline
WA_ISINCGFRMTNODETP3_D_STR-PARENTNODE sy-vline
WA_ISINCGFRMTNODETP3_D_STR-SIBLINGNODE sy-vline
WA_ISINCGFRMTNODETP3_D_STR-CHILDNODE sy-vline
WA_ISINCGFRMTNODETP3_D_STR-NODENAME sy-vline
WA_ISINCGFRMTNODETP3_D_STR-NODETYPE sy-vline
WA_ISINCGFRMTNODETP3_D_STR-HIERARCHYNODEISDEACTIVATED sy-vline
WA_ISINCGFRMTNODETP3_D_STR-HIERARCHYNODEREFERENCE sy-vline
WA_ISINCGFRMTNODETP3_D_STR-HIERARCHYNODESHORTTEXT sy-vline
WA_ISINCGFRMTNODETP3_D_STR-FIELDDELIMITERTYPE sy-vline
WA_ISINCGFRMTNODETP3_D_STR-FIELDDELIMITERVALUE sy-vline
WA_ISINCGFRMTNODETP3_D_STR-ENDOFLINEREPLACEMENTTYPE sy-vline
WA_ISINCGFRMTNODETP3_D_STR-ENDOFLINEREPLACEMENTVALUE sy-vline
WA_ISINCGFRMTNODETP3_D_STR-SOURCEVALUEOFFSET sy-vline
WA_ISINCGFRMTNODETP3_D_STR-SOURCEVALUELENGTH sy-vline
WA_ISINCGFRMTNODETP3_D_STR-CONTENTSTARTINGVALUE sy-vline
WA_ISINCGFRMTNODETP3_D_STR-CONTENTENDINGVALUE sy-vline
WA_ISINCGFRMTNODETP3_D_STR-HASACTIVEENTITY sy-vline
WA_ISINCGFRMTNODETP3_D_STR-DRAFTENTITYCREATIONDATETIME sy-vline
WA_ISINCGFRMTNODETP3_D_STR-DRAFTENTITYLASTCHANGEDATETIME sy-vline
WA_ISINCGFRMTNODETP3_D_STR-DRAFTADMINISTRATIVEDATAUUID sy-vline
WA_ISINCGFRMTNODETP3_D_STR-DRAFTENTITYCONSISTENCYSTATUS sy-vline
WA_ISINCGFRMTNODETP3_D_STR-DRAFTENTITYOPERATIONCODE sy-vline
WA_ISINCGFRMTNODETP3_D_STR-ISACTIVEENTITY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.