ABAP Select data from SAP table ISCMPLRQRSLTHZDSCLFNTP_DR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISCMPLRQRSLTHZDSCLFNTP_DR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISCMPLRQRSLTHZDSCLFNTP_DR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ISCMPLRQRSLTHZDSCLFNTP_DR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ISCMPLRQRSLTHZDSCLFNTP_DR TYPE STANDARD TABLE OF ISCMPLRQRSLTHZDSCLFNTP_DR,
      WA_ISCMPLRQRSLTHZDSCLFNTP_DR TYPE ISCMPLRQRSLTHZDSCLFNTP_DR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ISCMPLRQRSLTHZDSCLFNTP_DR> TYPE ISCMPLRQRSLTHZDSCLFNTP_DR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ISCMPLRQRSLTHZDSCLFNTP_DR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ISCMPLRQRSLTHZDSCLFNTP_DR
  INTO TABLE IT_ISCMPLRQRSLTHZDSCLFNTP_DR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ISCMPLRQRSLTHZDSCLFNTP_DR
*  INTO TABLE @DATA(IT_ISCMPLRQRSLTHZDSCLFNTP_DR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ISCMPLRQRSLTHZDSCLFNTP_DR INDEX 1 INTO DATA(WA_ISCMPLRQRSLTHZDSCLFNTP_DR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ISCMPLRQRSLTHZDSCLFNTP_DR ASSIGNING <ISCMPLRQRSLTHZDSCLFNTP_DR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISCMPLRQRSLTHZDSCLFNTP_DR>-CMPLRQRSLTUUID = 1.
<ISCMPLRQRSLTHZDSCLFNTP_DR>-ACTIVECMPLRQRSLTUUID = 1.
<ISCMPLRQRSLTHZDSCLFNTP_DR>-CMPLRQVERSUUID = 1.
<ISCMPLRQRSLTHZDSCLFNTP_DR>-CHMLCMPLNCINFOUUID = 1.
<ISCMPLRQRSLTHZDSCLFNTP_DR>-SUBSTANCEUUID = 1.
ENDLOOP.

LOOP AT IT_ISCMPLRQRSLTHZDSCLFNTP_DR INTO WA_ISCMPLRQRSLTHZDSCLFNTP_DR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ISCMPLRQRSLTHZDSCLFNTP_DR-CHMLSUPLRMATLUUID, sy-vline,
WA_ISCMPLRQRSLTHZDSCLFNTP_DR-COMPLIANCEREQUIREMENT, sy-vline,
WA_ISCMPLRQRSLTHZDSCLFNTP_DR-CREATIONDATETIME, sy-vline,
WA_ISCMPLRQRSLTHZDSCLFNTP_DR-CREATEDBYUSER, sy-vline,
WA_ISCMPLRQRSLTHZDSCLFNTP_DR-LASTCHANGEDATETIME, sy-vline,
WA_ISCMPLRQRSLTHZDSCLFNTP_DR-LASTCHANGEDBYUSER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISCMPLRQRSLTHZDSCLFNTP_DR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISCMPLRQRSLTHZDSCLFNTP_DR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISCMPLRQRSLTHZDSCLFNTP_DR INTO WA_ISCMPLRQRSLTHZDSCLFNTP_DR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PROCESSOR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISCMPLRQRSLTHZDSCLFNTP_DR-PROCESSOR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISCMPLRQRSLTHZDSCLFNTP_DR-PROCESSOR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RELEASEDBYUSER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISCMPLRQRSLTHZDSCLFNTP_DR-RELEASEDBYUSER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISCMPLRQRSLTHZDSCLFNTP_DR-RELEASEDBYUSER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISCMPLRQRSLTHZDSCLFNTP_DR_STR,
CMPLRQRSLTUUID TYPE STRING,
ACTIVECMPLRQRSLTUUID TYPE STRING,
CMPLRQVERSUUID TYPE STRING,
CHMLCMPLNCINFOUUID TYPE STRING,
SUBSTANCEUUID TYPE STRING,
CHMLSUPLRMATLUUID TYPE STRING,
COMPLIANCEREQUIREMENT TYPE STRING,
CREATIONDATETIME TYPE STRING,
CREATEDBYUSER TYPE STRING,
LASTCHANGEDATETIME TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
CMPLRQRSLTPROCESSINGSTATUS TYPE STRING,
PROCESSOR TYPE STRING,
RELEASEDBYUSER TYPE STRING,
VALIDITYSTARTDATETIME TYPE STRING,
VALIDITYENDDATETIME TYPE STRING,
CMPLRQRSLTRELDCMPLNCSTS TYPE STRING,
CMPLRQRSLTCALCULATEDSTATUS TYPE STRING,
CMPLRQRSLTMANUALSTATUS TYPE STRING,
CMPLRQRSLTSTATUSREMARK TYPE STRING,
CHMLCOMPOSITIONTYPE TYPE STRING,
MATERIALISSOLD TYPE STRING,
MATERIALISTRANSPORTED TYPE STRING,
MATERIALISSOURCED TYPE STRING,
MATERIALISPRODUCED TYPE STRING,
ACTIVEUUID TYPE STRING,
HASACTIVEENTITY TYPE STRING,
DRAFTENTITYCREATIONDATETIME TYPE STRING,
DRAFTENTITYLASTCHANGEDATETIME TYPE STRING,
DRAFTADMINISTRATIVEDATAUUID TYPE STRING,
DRAFTENTITYCONSISTENCYSTATUS TYPE STRING,
DRAFTENTITYOPERATIONCODE TYPE STRING,
ISACTIVEENTITY TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-CMPLRQRSLTUUID sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-ACTIVECMPLRQRSLTUUID sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-CMPLRQVERSUUID sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-CHMLCMPLNCINFOUUID sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-SUBSTANCEUUID sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-CHMLSUPLRMATLUUID sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-COMPLIANCEREQUIREMENT sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-CREATIONDATETIME sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-CREATEDBYUSER sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-LASTCHANGEDATETIME sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-LASTCHANGEDBYUSER sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-CMPLRQRSLTPROCESSINGSTATUS sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-PROCESSOR sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-RELEASEDBYUSER sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-VALIDITYSTARTDATETIME sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-VALIDITYENDDATETIME sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-CMPLRQRSLTRELDCMPLNCSTS sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-CMPLRQRSLTCALCULATEDSTATUS sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-CMPLRQRSLTMANUALSTATUS sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-CMPLRQRSLTSTATUSREMARK sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-CHMLCOMPOSITIONTYPE sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-MATERIALISSOLD sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-MATERIALISTRANSPORTED sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-MATERIALISSOURCED sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-MATERIALISPRODUCED sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-ACTIVEUUID sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-HASACTIVEENTITY sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-DRAFTENTITYCREATIONDATETIME sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-DRAFTENTITYLASTCHANGEDATETIME sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-DRAFTADMINISTRATIVEDATAUUID sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-DRAFTENTITYCONSISTENCYSTATUS sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-DRAFTENTITYOPERATIONCODE sy-vline
WA_ISCMPLRQRSLTHZDSCLFNTP_DR_STR-ISACTIVEENTITY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.