ABAP Select data from SAP table IQLTYCNTRLCHART into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IQLTYCNTRLCHART table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IQLTYCNTRLCHART. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IQLTYCNTRLCHART table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IQLTYCNTRLCHART TYPE STANDARD TABLE OF IQLTYCNTRLCHART,
      WA_IQLTYCNTRLCHART TYPE IQLTYCNTRLCHART,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IQLTYCNTRLCHART> TYPE IQLTYCNTRLCHART.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IQLTYCNTRLCHART.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IQLTYCNTRLCHART
  INTO TABLE IT_IQLTYCNTRLCHART.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IQLTYCNTRLCHART
*  INTO TABLE @DATA(IT_IQLTYCNTRLCHART2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IQLTYCNTRLCHART INDEX 1 INTO DATA(WA_IQLTYCNTRLCHART2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IQLTYCNTRLCHART ASSIGNING <IQLTYCNTRLCHART>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IQLTYCNTRLCHART>-MANDT = 1.
<IQLTYCNTRLCHART>-QUALITYCONTROLCHART = 1.
<IQLTYCNTRLCHART>-QUALITYCONTROLCHARTTYPE = 1.
<IQLTYCNTRLCHART>-QLTYCTRLCHARTAGGRGNCRITERION = 1.
<IQLTYCNTRLCHART>-PLANT = 1.
ENDLOOP.

LOOP AT IT_IQLTYCNTRLCHART INTO WA_IQLTYCNTRLCHART.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IQLTYCNTRLCHART-BILLOFOPERATIONSTYPE, sy-vline,
WA_IQLTYCNTRLCHART-BILLOFOPERATIONSGROUP, sy-vline,
WA_IQLTYCNTRLCHART-BILLOFOPERATIONSVARIANT, sy-vline,
WA_IQLTYCNTRLCHART-BILLOFOPERATIONSREFSEQUENCE, sy-vline,
WA_IQLTYCNTRLCHART-BOOOPERATIONINTERNALID, sy-vline,
WA_IQLTYCNTRLCHART-INSPECTIONCHARACTERISTIC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IQLTYCNTRLCHART you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IQLTYCNTRLCHART TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IQLTYCNTRLCHART INTO WA_IQLTYCNTRLCHART. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field QUALITYCONTROLCHART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IQLTYCNTRLCHART-QUALITYCONTROLCHART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IQLTYCNTRLCHART-QUALITYCONTROLCHART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BILLOFOPERATIONSGROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IQLTYCNTRLCHART-BILLOFOPERATIONSGROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IQLTYCNTRLCHART-BILLOFOPERATIONSGROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BILLOFOPERATIONSVARIANT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IQLTYCNTRLCHART-BILLOFOPERATIONSVARIANT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IQLTYCNTRLCHART-BILLOFOPERATIONSVARIANT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BILLOFOPERATIONSREFSEQUENCE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IQLTYCNTRLCHART-BILLOFOPERATIONSREFSEQUENCE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IQLTYCNTRLCHART-BILLOFOPERATIONSREFSEQUENCE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONSPECIFICATION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IQLTYCNTRLCHART-INSPECTIONSPECIFICATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IQLTYCNTRLCHART-INSPECTIONSPECIFICATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONLOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IQLTYCNTRLCHART-INSPECTIONLOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IQLTYCNTRLCHART-INSPECTIONLOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUIPMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IQLTYCNTRLCHART-EQUIPMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IQLTYCNTRLCHART-EQUIPMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field FUNCTIONALLOCATION CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_IQLTYCNTRLCHART-FUNCTIONALLOCATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IQLTYCNTRLCHART-FUNCTIONALLOCATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IQLTYCNTRLCHART-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IQLTYCNTRLCHART-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUPPLIER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IQLTYCNTRLCHART-SUPPLIER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IQLTYCNTRLCHART-SUPPLIER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IQLTYCNTRLCHART_STR,
MANDT TYPE STRING,
QUALITYCONTROLCHART TYPE STRING,
QUALITYCONTROLCHARTTYPE TYPE STRING,
QLTYCTRLCHARTAGGRGNCRITERION TYPE STRING,
PLANT TYPE STRING,
BILLOFOPERATIONSTYPE TYPE STRING,
BILLOFOPERATIONSGROUP TYPE STRING,
BILLOFOPERATIONSVARIANT TYPE STRING,
BILLOFOPERATIONSREFSEQUENCE TYPE STRING,
BOOOPERATIONINTERNALID TYPE STRING,
INSPECTIONCHARACTERISTIC TYPE STRING,
INSPECTIONSPECIFICATIONPLANT TYPE STRING,
INSPECTIONSPECIFICATION TYPE STRING,
INSPECTIONLOT TYPE STRING,
WORKCENTER TYPE STRING,
MAINWORKCENTERPLANT TYPE STRING,
EQUIPMENT TYPE STRING,
FUNCTIONALLOCATION TYPE STRING,
MATERIAL TYPE STRING,
SUPPLIER TYPE STRING,
QUALITYCONTROLCHARTTEXT TYPE STRING,
QUALITYCONTROLCHARTSTATUS TYPE STRING,
QLTYCTRLCHARTCREATEDBYUSER TYPE STRING,
QLTYCTRLCHARTCREATIONDATE TYPE STRING,
QLTYCTRLCHARTCREATIONTIME TYPE STRING,
QLTYCTRLCHARTLASTCHANGEDBYUSER TYPE STRING,
QLTYCTRLCHARTLASTCHANGEDDATE TYPE STRING,
QLTYCTRLCHARTLASTCHANGEDTIME TYPE STRING,
INSPSPECUPPERLIMIT TYPE STRING,
INSPSPECHASUPPERLIMIT TYPE STRING,
INSPSPECLOWERLIMIT TYPE STRING,
INSPSPECHASLOWERLIMIT TYPE STRING,END OF T_EKKO_STR. DATA: WA_IQLTYCNTRLCHART_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IQLTYCNTRLCHART_STR-MANDT sy-vline
WA_IQLTYCNTRLCHART_STR-QUALITYCONTROLCHART sy-vline
WA_IQLTYCNTRLCHART_STR-QUALITYCONTROLCHARTTYPE sy-vline
WA_IQLTYCNTRLCHART_STR-QLTYCTRLCHARTAGGRGNCRITERION sy-vline
WA_IQLTYCNTRLCHART_STR-PLANT sy-vline
WA_IQLTYCNTRLCHART_STR-BILLOFOPERATIONSTYPE sy-vline
WA_IQLTYCNTRLCHART_STR-BILLOFOPERATIONSGROUP sy-vline
WA_IQLTYCNTRLCHART_STR-BILLOFOPERATIONSVARIANT sy-vline
WA_IQLTYCNTRLCHART_STR-BILLOFOPERATIONSREFSEQUENCE sy-vline
WA_IQLTYCNTRLCHART_STR-BOOOPERATIONINTERNALID sy-vline
WA_IQLTYCNTRLCHART_STR-INSPECTIONCHARACTERISTIC sy-vline
WA_IQLTYCNTRLCHART_STR-INSPECTIONSPECIFICATIONPLANT sy-vline
WA_IQLTYCNTRLCHART_STR-INSPECTIONSPECIFICATION sy-vline
WA_IQLTYCNTRLCHART_STR-INSPECTIONLOT sy-vline
WA_IQLTYCNTRLCHART_STR-WORKCENTER sy-vline
WA_IQLTYCNTRLCHART_STR-MAINWORKCENTERPLANT sy-vline
WA_IQLTYCNTRLCHART_STR-EQUIPMENT sy-vline
WA_IQLTYCNTRLCHART_STR-FUNCTIONALLOCATION sy-vline
WA_IQLTYCNTRLCHART_STR-MATERIAL sy-vline
WA_IQLTYCNTRLCHART_STR-SUPPLIER sy-vline
WA_IQLTYCNTRLCHART_STR-QUALITYCONTROLCHARTTEXT sy-vline
WA_IQLTYCNTRLCHART_STR-QUALITYCONTROLCHARTSTATUS sy-vline
WA_IQLTYCNTRLCHART_STR-QLTYCTRLCHARTCREATEDBYUSER sy-vline
WA_IQLTYCNTRLCHART_STR-QLTYCTRLCHARTCREATIONDATE sy-vline
WA_IQLTYCNTRLCHART_STR-QLTYCTRLCHARTCREATIONTIME sy-vline
WA_IQLTYCNTRLCHART_STR-QLTYCTRLCHARTLASTCHANGEDBYUSER sy-vline
WA_IQLTYCNTRLCHART_STR-QLTYCTRLCHARTLASTCHANGEDDATE sy-vline
WA_IQLTYCNTRLCHART_STR-QLTYCTRLCHARTLASTCHANGEDTIME sy-vline
WA_IQLTYCNTRLCHART_STR-INSPSPECUPPERLIMIT sy-vline
WA_IQLTYCNTRLCHART_STR-INSPSPECHASUPPERLIMIT sy-vline
WA_IQLTYCNTRLCHART_STR-INSPSPECLOWERLIMIT sy-vline
WA_IQLTYCNTRLCHART_STR-INSPSPECHASLOWERLIMIT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.