ABAP Select data from SAP table IPRODEWMSTORTP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IPRODEWMSTORTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IPRODEWMSTORTP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IPRODEWMSTORTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IPRODEWMSTORTP TYPE STANDARD TABLE OF IPRODEWMSTORTP,
      WA_IPRODEWMSTORTP TYPE IPRODEWMSTORTP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IPRODEWMSTORTP> TYPE IPRODEWMSTORTP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IPRODEWMSTORTP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IPRODEWMSTORTP
  INTO TABLE IT_IPRODEWMSTORTP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IPRODEWMSTORTP
*  INTO TABLE @DATA(IT_IPRODEWMSTORTP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IPRODEWMSTORTP INDEX 1 INTO DATA(WA_IPRODEWMSTORTP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IPRODEWMSTORTP ASSIGNING <IPRODEWMSTORTP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IPRODEWMSTORTP>-MANDT = 1.
<IPRODEWMSTORTP>-PRODUCT = 1.
<IPRODEWMSTORTP>-WAREHOUSE = 1.
<IPRODEWMSTORTP>-BUSINESSPARTNER = 1.
<IPRODEWMSTORTP>-STORAGETYPE = 1.
ENDLOOP.

LOOP AT IT_IPRODEWMSTORTP INTO WA_IPRODEWMSTORTP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IPRODEWMSTORTP-STORAGETYPEFOREDIT, sy-vline,
WA_IPRODEWMSTORTP-WAREHOUSEFOREDIT, sy-vline,
WA_IPRODEWMSTORTP-SUPPLYCHAINUNITUUID, sy-vline,
WA_IPRODEWMSTORTP-PRODUCTUUID, sy-vline,
WA_IPRODEWMSTORTP-BUSINESSPARTNERUUID, sy-vline,
WA_IPRODEWMSTORTP-EWMSTORAGESECTIONMETHOD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IPRODEWMSTORTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IPRODEWMSTORTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IPRODEWMSTORTP INTO WA_IPRODEWMSTORTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field PRODUCT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IPRODEWMSTORTP-PRODUCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRODEWMSTORTP-PRODUCT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BUSINESSPARTNER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRODEWMSTORTP-BUSINESSPARTNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRODEWMSTORTP-BUSINESSPARTNER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EWMMINREPLNMTQUANTITYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPRODEWMSTORTP-EWMMINREPLNMTQUANTITYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRODEWMSTORTP-EWMMINREPLNMTQUANTITYUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EWMMINIMUMSTORAGEQUANTITYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPRODEWMSTORTP-EWMMINIMUMSTORAGEQUANTITYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRODEWMSTORTP-EWMMINIMUMSTORAGEQUANTITYUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EWMMAXIMUMSTORAGEQUANTITYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPRODEWMSTORTP-EWMMAXIMUMSTORAGEQUANTITYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRODEWMSTORTP-EWMMAXIMUMSTORAGEQUANTITYUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IPRODEWMSTORTP_STR,
MANDT TYPE STRING,
PRODUCT TYPE STRING,
WAREHOUSE TYPE STRING,
BUSINESSPARTNER TYPE STRING,
STORAGETYPE TYPE STRING,
STORAGETYPEFOREDIT TYPE STRING,
WAREHOUSEFOREDIT TYPE STRING,
SUPPLYCHAINUNITUUID TYPE STRING,
PRODUCTUUID TYPE STRING,
BUSINESSPARTNERUUID TYPE STRING,
EWMSTORAGESECTIONMETHOD TYPE STRING,
STORAGEBINTYPE TYPE STRING,
EWMSTORAGEBINSEARCHRULE TYPE STRING,
EWMMAXIMUMNUMBEROFBINS TYPE STRING,
EWMSPLTPTWYTHRESHOLDINPERCENT TYPE STRING,
EWMPTWYSEQUENCE TYPE STRING,
EWMPRODQUANTITYCLASSIFICATION TYPE STRING,
EWMPRODPTWYQTYCLASSIFICATION TYPE STRING,
EWMPRODISSPLITONPTWY TYPE STRING,
EWMPRODISSKIPPEDONPTWY TYPE STRING,
EWMHASNOREPLENISHMENT TYPE STRING,
EWMMINREPLNMTQUANTITY TYPE STRING,
EWMMINREPLNMTQUANTITYUNIT TYPE STRING,
EWMMINIMUMSTORAGEQUANTITY TYPE STRING,
EWMMINIMUMSTORAGEQUANTITYUNIT TYPE STRING,
EWMMAXIMUMSTORAGEQUANTITY TYPE STRING,
EWMMAXIMUMSTORAGEQUANTITYUNIT TYPE STRING,
EWMMINSTORQTYOFMAXSTORQTYINPCT TYPE STRING,END OF T_EKKO_STR. DATA: WA_IPRODEWMSTORTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IPRODEWMSTORTP_STR-MANDT sy-vline
WA_IPRODEWMSTORTP_STR-PRODUCT sy-vline
WA_IPRODEWMSTORTP_STR-WAREHOUSE sy-vline
WA_IPRODEWMSTORTP_STR-BUSINESSPARTNER sy-vline
WA_IPRODEWMSTORTP_STR-STORAGETYPE sy-vline
WA_IPRODEWMSTORTP_STR-STORAGETYPEFOREDIT sy-vline
WA_IPRODEWMSTORTP_STR-WAREHOUSEFOREDIT sy-vline
WA_IPRODEWMSTORTP_STR-SUPPLYCHAINUNITUUID sy-vline
WA_IPRODEWMSTORTP_STR-PRODUCTUUID sy-vline
WA_IPRODEWMSTORTP_STR-BUSINESSPARTNERUUID sy-vline
WA_IPRODEWMSTORTP_STR-EWMSTORAGESECTIONMETHOD sy-vline
WA_IPRODEWMSTORTP_STR-STORAGEBINTYPE sy-vline
WA_IPRODEWMSTORTP_STR-EWMSTORAGEBINSEARCHRULE sy-vline
WA_IPRODEWMSTORTP_STR-EWMMAXIMUMNUMBEROFBINS sy-vline
WA_IPRODEWMSTORTP_STR-EWMSPLTPTWYTHRESHOLDINPERCENT sy-vline
WA_IPRODEWMSTORTP_STR-EWMPTWYSEQUENCE sy-vline
WA_IPRODEWMSTORTP_STR-EWMPRODQUANTITYCLASSIFICATION sy-vline
WA_IPRODEWMSTORTP_STR-EWMPRODPTWYQTYCLASSIFICATION sy-vline
WA_IPRODEWMSTORTP_STR-EWMPRODISSPLITONPTWY sy-vline
WA_IPRODEWMSTORTP_STR-EWMPRODISSKIPPEDONPTWY sy-vline
WA_IPRODEWMSTORTP_STR-EWMHASNOREPLENISHMENT sy-vline
WA_IPRODEWMSTORTP_STR-EWMMINREPLNMTQUANTITY sy-vline
WA_IPRODEWMSTORTP_STR-EWMMINREPLNMTQUANTITYUNIT sy-vline
WA_IPRODEWMSTORTP_STR-EWMMINIMUMSTORAGEQUANTITY sy-vline
WA_IPRODEWMSTORTP_STR-EWMMINIMUMSTORAGEQUANTITYUNIT sy-vline
WA_IPRODEWMSTORTP_STR-EWMMAXIMUMSTORAGEQUANTITY sy-vline
WA_IPRODEWMSTORTP_STR-EWMMAXIMUMSTORAGEQUANTITYUNIT sy-vline
WA_IPRODEWMSTORTP_STR-EWMMINSTORQTYOFMAXSTORQTYINPCT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.