ABAP Select data from SAP table IPRATVCOMBINEACT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IPRATVCOMBINEACT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IPRATVCOMBINEACT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IPRATVCOMBINEACT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IPRATVCOMBINEACT TYPE STANDARD TABLE OF IPRATVCOMBINEACT,
      WA_IPRATVCOMBINEACT TYPE IPRATVCOMBINEACT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IPRATVCOMBINEACT> TYPE IPRATVCOMBINEACT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IPRATVCOMBINEACT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IPRATVCOMBINEACT
  INTO TABLE IT_IPRATVCOMBINEACT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IPRATVCOMBINEACT
*  INTO TABLE @DATA(IT_IPRATVCOMBINEACT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IPRATVCOMBINEACT INDEX 1 INTO DATA(WA_IPRATVCOMBINEACT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IPRATVCOMBINEACT ASSIGNING <IPRATVCOMBINEACT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IPRATVCOMBINEACT>-MANDT = 1.
<IPRATVCOMBINEACT>-CURRENTVALNDOCUMENT = 1.
<IPRATVCOMBINEACT>-CURRENTVALNDOCUMENTYEAR = 1.
<IPRATVCOMBINEACT>-DELIVERYNETWORK = 1.
<IPRATVCOMBINEACT>-SALESDATE = 1.
ENDLOOP.

LOOP AT IT_IPRATVCOMBINEACT INTO WA_IPRATVCOMBINEACT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IPRATVCOMBINEACT-PRAJOINTVENTURE, sy-vline,
WA_IPRATVCOMBINEACT-DIVISIONOFINTEREST, sy-vline,
WA_IPRATVCOMBINEACT-PRACONTRACT, sy-vline,
WA_IPRATVCOMBINEACT-WELL, sy-vline,
WA_IPRATVCOMBINEACT-WELLCOMPLETION, sy-vline,
WA_IPRATVCOMBINEACT-ORIGINATINGMEASUREMENTPT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IPRATVCOMBINEACT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IPRATVCOMBINEACT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IPRATVCOMBINEACT INTO WA_IPRATVCOMBINEACT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CURRENTVALNDOCUMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATVCOMBINEACT-CURRENTVALNDOCUMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATVCOMBINEACT-CURRENTVALNDOCUMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field CURRENTVALNDOCUMENTYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_IPRATVCOMBINEACT-CURRENTVALNDOCUMENTYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATVCOMBINEACT-CURRENTVALNDOCUMENTYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DELIVERYNETWORK CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATVCOMBINEACT-DELIVERYNETWORK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATVCOMBINEACT-DELIVERYNETWORK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRAJOINTVENTURE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATVCOMBINEACT-PRAJOINTVENTURE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATVCOMBINEACT-PRAJOINTVENTURE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DIVISIONOFINTEREST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATVCOMBINEACT-DIVISIONOFINTEREST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATVCOMBINEACT-DIVISIONOFINTEREST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRACONTRACT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATVCOMBINEACT-PRACONTRACT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATVCOMBINEACT-PRACONTRACT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WELL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATVCOMBINEACT-WELL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATVCOMBINEACT-WELL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WELLCOMPLETION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATVCOMBINEACT-WELLCOMPLETION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATVCOMBINEACT-WELLCOMPLETION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ORIGINATINGMEASUREMENTPT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATVCOMBINEACT-ORIGINATINGMEASUREMENTPT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATVCOMBINEACT-ORIGINATINGMEASUREMENTPT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IPRATVCOMBINEACT-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATVCOMBINEACT-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GLACCOUNT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATVCOMBINEACT-GLACCOUNT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATVCOMBINEACT-GLACCOUNT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COSTCENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATVCOMBINEACT-COSTCENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATVCOMBINEACT-COSTCENTER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ACCTSRBLMEASUREMENTPT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATVCOMBINEACT-ACCTSRBLMEASUREMENTPT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATVCOMBINEACT-ACCTSRBLMEASUREMENTPT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLUMEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPRATVCOMBINEACT-VOLUMEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATVCOMBINEACT-VOLUMEUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ENERGYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPRATVCOMBINEACT-ENERGYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATVCOMBINEACT-ENERGYUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IPRATVCOMBINEACT_STR,
MANDT TYPE STRING,
CURRENTVALNDOCUMENT TYPE STRING,
CURRENTVALNDOCUMENTYEAR TYPE STRING,
DELIVERYNETWORK TYPE STRING,
SALESDATE TYPE STRING,
PRAJOINTVENTURE TYPE STRING,
DIVISIONOFINTEREST TYPE STRING,
PRACONTRACT TYPE STRING,
WELL TYPE STRING,
WELLCOMPLETION TYPE STRING,
ORIGINATINGMEASUREMENTPT TYPE STRING,
MATERIAL TYPE STRING,
COMBINEDHDRSQNCNUMBER TYPE STRING,
PROCESSINGCOMPANYCODE TYPE STRING,
GLACCOUNT TYPE STRING,
ACCTDETERMINATIONCATEGORY TYPE STRING,
COSTCENTER TYPE STRING,
ALTERNATEPROPERTY TYPE STRING,
ACCTSRBLMEASUREMENTPT TYPE STRING,
TOTALCREDITAMOUNT TYPE STRING,
TOTALDEBITAMOUNT TYPE STRING,
ACTUALGROSSVOLUME TYPE STRING,
ACTUALENERGY TYPE STRING,
ACTUALVOLREDUCN TYPE STRING,
ACTUALENERGYREDUCN TYPE STRING,
COMPANYCODECURRENCY TYPE STRING,
VOLUMEUNIT TYPE STRING,
ENERGYUNIT TYPE STRING,
SEQUENCENUMBER TYPE STRING,END OF T_EKKO_STR. DATA: WA_IPRATVCOMBINEACT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IPRATVCOMBINEACT_STR-MANDT sy-vline
WA_IPRATVCOMBINEACT_STR-CURRENTVALNDOCUMENT sy-vline
WA_IPRATVCOMBINEACT_STR-CURRENTVALNDOCUMENTYEAR sy-vline
WA_IPRATVCOMBINEACT_STR-DELIVERYNETWORK sy-vline
WA_IPRATVCOMBINEACT_STR-SALESDATE sy-vline
WA_IPRATVCOMBINEACT_STR-PRAJOINTVENTURE sy-vline
WA_IPRATVCOMBINEACT_STR-DIVISIONOFINTEREST sy-vline
WA_IPRATVCOMBINEACT_STR-PRACONTRACT sy-vline
WA_IPRATVCOMBINEACT_STR-WELL sy-vline
WA_IPRATVCOMBINEACT_STR-WELLCOMPLETION sy-vline
WA_IPRATVCOMBINEACT_STR-ORIGINATINGMEASUREMENTPT sy-vline
WA_IPRATVCOMBINEACT_STR-MATERIAL sy-vline
WA_IPRATVCOMBINEACT_STR-COMBINEDHDRSQNCNUMBER sy-vline
WA_IPRATVCOMBINEACT_STR-PROCESSINGCOMPANYCODE sy-vline
WA_IPRATVCOMBINEACT_STR-GLACCOUNT sy-vline
WA_IPRATVCOMBINEACT_STR-ACCTDETERMINATIONCATEGORY sy-vline
WA_IPRATVCOMBINEACT_STR-COSTCENTER sy-vline
WA_IPRATVCOMBINEACT_STR-ALTERNATEPROPERTY sy-vline
WA_IPRATVCOMBINEACT_STR-ACCTSRBLMEASUREMENTPT sy-vline
WA_IPRATVCOMBINEACT_STR-TOTALCREDITAMOUNT sy-vline
WA_IPRATVCOMBINEACT_STR-TOTALDEBITAMOUNT sy-vline
WA_IPRATVCOMBINEACT_STR-ACTUALGROSSVOLUME sy-vline
WA_IPRATVCOMBINEACT_STR-ACTUALENERGY sy-vline
WA_IPRATVCOMBINEACT_STR-ACTUALVOLREDUCN sy-vline
WA_IPRATVCOMBINEACT_STR-ACTUALENERGYREDUCN sy-vline
WA_IPRATVCOMBINEACT_STR-COMPANYCODECURRENCY sy-vline
WA_IPRATVCOMBINEACT_STR-VOLUMEUNIT sy-vline
WA_IPRATVCOMBINEACT_STR-ENERGYUNIT sy-vline
WA_IPRATVCOMBINEACT_STR-SEQUENCENUMBER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.