ABAP Select data from SAP table IPRATSTASPC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IPRATSTASPC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IPRATSTASPC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IPRATSTASPC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IPRATSTASPC TYPE STANDARD TABLE OF IPRATSTASPC,
      WA_IPRATSTASPC TYPE IPRATSTASPC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IPRATSTASPC> TYPE IPRATSTASPC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IPRATSTASPC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IPRATSTASPC
  INTO TABLE IT_IPRATSTASPC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IPRATSTASPC
*  INTO TABLE @DATA(IT_IPRATSTASPC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IPRATSTASPC INDEX 1 INTO DATA(WA_IPRATSTASPC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IPRATSTASPC ASSIGNING <IPRATSTASPC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IPRATSTASPC>-MANDT = 1.
<IPRATSTASPC>-DELIVERYNETWORK = 1.
<IPRATSTASPC>-WELL = 1.
<IPRATSTASPC>-WELLCOMPLETION = 1.
<IPRATSTASPC>-MATERIAL = 1.
ENDLOOP.

LOOP AT IT_IPRATSTASPC INTO WA_IPRATSTASPC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IPRATSTASPC-PRACONTRACT, sy-vline,
WA_IPRATSTASPC-SALESDATE, sy-vline,
WA_IPRATSTASPC-PRAOWNER, sy-vline,
WA_IPRATSTASPC-OWNERINTERESTTYPE, sy-vline,
WA_IPRATSTASPC-OWNERINTERESTSEQUENCE, sy-vline,
WA_IPRATSTASPC-ORIGINATINGMEASUREMENTPT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IPRATSTASPC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IPRATSTASPC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IPRATSTASPC INTO WA_IPRATSTASPC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DELIVERYNETWORK CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATSTASPC-DELIVERYNETWORK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATSTASPC-DELIVERYNETWORK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WELL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATSTASPC-WELL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATSTASPC-WELL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WELLCOMPLETION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATSTASPC-WELLCOMPLETION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATSTASPC-WELLCOMPLETION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IPRATSTASPC-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATSTASPC-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRACONTRACT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATSTASPC-PRACONTRACT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATSTASPC-PRACONTRACT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRAOWNER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATSTASPC-PRAOWNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATSTASPC-PRAOWNER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OWNERINTERESTSEQUENCE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATSTASPC-OWNERINTERESTSEQUENCE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATSTASPC-OWNERINTERESTSEQUENCE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ORIGINATINGMEASUREMENTPT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATSTASPC-ORIGINATINGMEASUREMENTPT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATSTASPC-ORIGINATINGMEASUREMENTPT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRANSPORTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATSTASPC-TRANSPORTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATSTASPC-TRANSPORTER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLUMEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPRATSTASPC-VOLUMEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATSTASPC-VOLUMEUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field HEATINGVALUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPRATSTASPC-HEATINGVALUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATSTASPC-HEATINGVALUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ENERGYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPRATSTASPC-ENERGYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATSTASPC-ENERGYUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IPRATSTASPC_STR,
MANDT TYPE STRING,
DELIVERYNETWORK TYPE STRING,
WELL TYPE STRING,
WELLCOMPLETION TYPE STRING,
MATERIAL TYPE STRING,
PRACONTRACT TYPE STRING,
SALESDATE TYPE STRING,
PRAOWNER TYPE STRING,
OWNERINTERESTTYPE TYPE STRING,
OWNERINTERESTSEQUENCE TYPE STRING,
ORIGINATINGMEASUREMENTPT TYPE STRING,
TRANSPORTER TYPE STRING,
MAJORPRODUCT TYPE STRING,
BASELINEACTUALVOLUME TYPE STRING,
ACTUALVOLUME TYPE STRING,
ACTUALVOLUMEDIFFVAL TYPE STRING,
VOLUMEUNIT TYPE STRING,
BASELINEACTUALHEATINGVALUE TYPE STRING,
ACTUALHEATINGVALUE TYPE STRING,
ACTUALHEATINGVALUEDIFFVAL TYPE STRING,
HEATINGVALUNIT TYPE STRING,
BASELINEACTUALENERGY TYPE STRING,
ACTUALENERGY TYPE STRING,
ACTUALENERGYDIFFVAL TYPE STRING,
ENERGYUNIT TYPE STRING,
BASELINEENTITLEDVOLUME TYPE STRING,
ENTITLEDVOLUME TYPE STRING,
ENTITLEDVOLUMEDIFFVAL TYPE STRING,
BASELINEENTITLEDENERGY TYPE STRING,
ENTITLEDENERGY TYPE STRING,
ENTITLEDENERGYDIFFVAL TYPE STRING,
CREATEDBYUSER TYPE STRING,
CREATIONDATETIME TYPE STRING,
SEQUENCENUMBER TYPE STRING,
SECDRYACTLVOLTOLVAL TYPE STRING,
SECDRYACTLHEATVALTOLVAL TYPE STRING,
SECDRYACTLENGYTOLVAL TYPE STRING,
SECDRYENTLDVOLTOLVAL TYPE STRING,
SECDRYENTLDENGYTOLVAL TYPE STRING,END OF T_EKKO_STR. DATA: WA_IPRATSTASPC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IPRATSTASPC_STR-MANDT sy-vline
WA_IPRATSTASPC_STR-DELIVERYNETWORK sy-vline
WA_IPRATSTASPC_STR-WELL sy-vline
WA_IPRATSTASPC_STR-WELLCOMPLETION sy-vline
WA_IPRATSTASPC_STR-MATERIAL sy-vline
WA_IPRATSTASPC_STR-PRACONTRACT sy-vline
WA_IPRATSTASPC_STR-SALESDATE sy-vline
WA_IPRATSTASPC_STR-PRAOWNER sy-vline
WA_IPRATSTASPC_STR-OWNERINTERESTTYPE sy-vline
WA_IPRATSTASPC_STR-OWNERINTERESTSEQUENCE sy-vline
WA_IPRATSTASPC_STR-ORIGINATINGMEASUREMENTPT sy-vline
WA_IPRATSTASPC_STR-TRANSPORTER sy-vline
WA_IPRATSTASPC_STR-MAJORPRODUCT sy-vline
WA_IPRATSTASPC_STR-BASELINEACTUALVOLUME sy-vline
WA_IPRATSTASPC_STR-ACTUALVOLUME sy-vline
WA_IPRATSTASPC_STR-ACTUALVOLUMEDIFFVAL sy-vline
WA_IPRATSTASPC_STR-VOLUMEUNIT sy-vline
WA_IPRATSTASPC_STR-BASELINEACTUALHEATINGVALUE sy-vline
WA_IPRATSTASPC_STR-ACTUALHEATINGVALUE sy-vline
WA_IPRATSTASPC_STR-ACTUALHEATINGVALUEDIFFVAL sy-vline
WA_IPRATSTASPC_STR-HEATINGVALUNIT sy-vline
WA_IPRATSTASPC_STR-BASELINEACTUALENERGY sy-vline
WA_IPRATSTASPC_STR-ACTUALENERGY sy-vline
WA_IPRATSTASPC_STR-ACTUALENERGYDIFFVAL sy-vline
WA_IPRATSTASPC_STR-ENERGYUNIT sy-vline
WA_IPRATSTASPC_STR-BASELINEENTITLEDVOLUME sy-vline
WA_IPRATSTASPC_STR-ENTITLEDVOLUME sy-vline
WA_IPRATSTASPC_STR-ENTITLEDVOLUMEDIFFVAL sy-vline
WA_IPRATSTASPC_STR-BASELINEENTITLEDENERGY sy-vline
WA_IPRATSTASPC_STR-ENTITLEDENERGY sy-vline
WA_IPRATSTASPC_STR-ENTITLEDENERGYDIFFVAL sy-vline
WA_IPRATSTASPC_STR-CREATEDBYUSER sy-vline
WA_IPRATSTASPC_STR-CREATIONDATETIME sy-vline
WA_IPRATSTASPC_STR-SEQUENCENUMBER sy-vline
WA_IPRATSTASPC_STR-SECDRYACTLVOLTOLVAL sy-vline
WA_IPRATSTASPC_STR-SECDRYACTLHEATVALTOLVAL sy-vline
WA_IPRATSTASPC_STR-SECDRYACTLENGYTOLVAL sy-vline
WA_IPRATSTASPC_STR-SECDRYENTLDVOLTOLVAL sy-vline
WA_IPRATSTASPC_STR-SECDRYENTLDENGYTOLVAL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.