ABAP Select data from SAP table IPRATPCUI into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IPRATPCUI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IPRATPCUI. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IPRATPCUI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IPRATPCUI TYPE STANDARD TABLE OF IPRATPCUI,
      WA_IPRATPCUI TYPE IPRATPCUI,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IPRATPCUI> TYPE IPRATPCUI.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IPRATPCUI.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IPRATPCUI
  INTO TABLE IT_IPRATPCUI.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IPRATPCUI
*  INTO TABLE @DATA(IT_IPRATPCUI2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IPRATPCUI INDEX 1 INTO DATA(WA_IPRATPCUI2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IPRATPCUI ASSIGNING <IPRATPCUI>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IPRATPCUI>-MANDT = 1.
<IPRATPCUI>-PRATSTALLOCVERSION = 1.
<IPRATPCUI>-WELLCOMPLTNVOLDOC = 1.
<IPRATPCUI>-WELLCOMPLTNVOLDOCYR = 1.
<IPRATPCUI>-DELIVERYNETWORK = 1.
ENDLOOP.

LOOP AT IT_IPRATPCUI INTO WA_IPRATPCUI.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IPRATPCUI-ALLOCATIONFREQUENCY, sy-vline,
WA_IPRATPCUI-PRODUCTIONDATE, sy-vline,
WA_IPRATPCUI-MAJORPRODUCT, sy-vline,
WA_IPRATPCUI-WELL, sy-vline,
WA_IPRATPCUI-WELLCOMPLETION, sy-vline,
WA_IPRATPCUI-VOLUMETYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IPRATPCUI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IPRATPCUI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IPRATPCUI INTO WA_IPRATPCUI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field WELLCOMPLTNVOLDOC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATPCUI-WELLCOMPLTNVOLDOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATPCUI-WELLCOMPLTNVOLDOC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field WELLCOMPLTNVOLDOCYR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_IPRATPCUI-WELLCOMPLTNVOLDOCYR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATPCUI-WELLCOMPLTNVOLDOCYR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DELIVERYNETWORK CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATPCUI-DELIVERYNETWORK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATPCUI-DELIVERYNETWORK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WELL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATPCUI-WELL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATPCUI-WELL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WELLCOMPLETION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATPCUI-WELLCOMPLETION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATPCUI-WELLCOMPLETION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRANSPORTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATPCUI-TRANSPORTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATPCUI-TRANSPORTER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ORIGINATINGMEASUREMENTPT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATPCUI-ORIGINATINGMEASUREMENTPT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATPCUI-ORIGINATINGMEASUREMENTPT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field STANDARDVOLUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPRATPCUI-STANDARDVOLUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATPCUI-STANDARDVOLUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field STANDARDDENSITYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPRATPCUI-STANDARDDENSITYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATPCUI-STANDARDDENSITYUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ENERGYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPRATPCUI-ENERGYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATPCUI-ENERGYUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field HEATINGVALUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPRATPCUI-HEATINGVALUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATPCUI-HEATINGVALUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IPRATPCUI-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATPCUI-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field BASELINEMATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IPRATPCUI-BASELINEMATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATPCUI-BASELINEMATERIAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IPRATPCUI_STR,
MANDT TYPE STRING,
PRATSTALLOCVERSION TYPE STRING,
WELLCOMPLTNVOLDOC TYPE STRING,
WELLCOMPLTNVOLDOCYR TYPE STRING,
DELIVERYNETWORK TYPE STRING,
ALLOCATIONFREQUENCY TYPE STRING,
PRODUCTIONDATE TYPE STRING,
MAJORPRODUCT TYPE STRING,
WELL TYPE STRING,
WELLCOMPLETION TYPE STRING,
VOLUMETYPE TYPE STRING,
TICKETNUMBER TYPE STRING,
TRANSPORTER TYPE STRING,
EFFECTIVEVALIDITYSTARTDATE TYPE STRING,
INVENTORYDATE TYPE STRING,
ORIGINATINGMEASUREMENTPT TYPE STRING,
STANDARDVOLUME TYPE STRING,
STANDARDVOLUNIT TYPE STRING,
BASELINESTANDARDVOLUME TYPE STRING,
ACTUALVOLUMESTSCRITLTY TYPE STRING,
STANDARDDENSITY TYPE STRING,
STANDARDDENSITYUNIT TYPE STRING,
BASELINESTANDARDDENSITY TYPE STRING,
STDDENSSTSCRITLTY TYPE STRING,
ENERGY TYPE STRING,
ENERGYUNIT TYPE STRING,
BASELINEENERGY TYPE STRING,
ACTUALENERGYSTSCRITLTY TYPE STRING,
HEATINGVALUE TYPE STRING,
HEATINGVALUNIT TYPE STRING,
BASELINEHEATINGVALUE TYPE STRING,
ACTUALHEATINGVALUESTSCRITLTY TYPE STRING,
NMBROFDAYSPRODUCED TYPE STRING,
BSLNNMBROFDAYSPRODUCED TYPE STRING,
DAYSPRODUCEDSTSCRITLTY TYPE STRING,
MATERIAL TYPE STRING,
BASELINEMATERIAL TYPE STRING,
PRATSTMATERIALSTSCRITLTY TYPE STRING,END OF T_EKKO_STR. DATA: WA_IPRATPCUI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IPRATPCUI_STR-MANDT sy-vline
WA_IPRATPCUI_STR-PRATSTALLOCVERSION sy-vline
WA_IPRATPCUI_STR-WELLCOMPLTNVOLDOC sy-vline
WA_IPRATPCUI_STR-WELLCOMPLTNVOLDOCYR sy-vline
WA_IPRATPCUI_STR-DELIVERYNETWORK sy-vline
WA_IPRATPCUI_STR-ALLOCATIONFREQUENCY sy-vline
WA_IPRATPCUI_STR-PRODUCTIONDATE sy-vline
WA_IPRATPCUI_STR-MAJORPRODUCT sy-vline
WA_IPRATPCUI_STR-WELL sy-vline
WA_IPRATPCUI_STR-WELLCOMPLETION sy-vline
WA_IPRATPCUI_STR-VOLUMETYPE sy-vline
WA_IPRATPCUI_STR-TICKETNUMBER sy-vline
WA_IPRATPCUI_STR-TRANSPORTER sy-vline
WA_IPRATPCUI_STR-EFFECTIVEVALIDITYSTARTDATE sy-vline
WA_IPRATPCUI_STR-INVENTORYDATE sy-vline
WA_IPRATPCUI_STR-ORIGINATINGMEASUREMENTPT sy-vline
WA_IPRATPCUI_STR-STANDARDVOLUME sy-vline
WA_IPRATPCUI_STR-STANDARDVOLUNIT sy-vline
WA_IPRATPCUI_STR-BASELINESTANDARDVOLUME sy-vline
WA_IPRATPCUI_STR-ACTUALVOLUMESTSCRITLTY sy-vline
WA_IPRATPCUI_STR-STANDARDDENSITY sy-vline
WA_IPRATPCUI_STR-STANDARDDENSITYUNIT sy-vline
WA_IPRATPCUI_STR-BASELINESTANDARDDENSITY sy-vline
WA_IPRATPCUI_STR-STDDENSSTSCRITLTY sy-vline
WA_IPRATPCUI_STR-ENERGY sy-vline
WA_IPRATPCUI_STR-ENERGYUNIT sy-vline
WA_IPRATPCUI_STR-BASELINEENERGY sy-vline
WA_IPRATPCUI_STR-ACTUALENERGYSTSCRITLTY sy-vline
WA_IPRATPCUI_STR-HEATINGVALUE sy-vline
WA_IPRATPCUI_STR-HEATINGVALUNIT sy-vline
WA_IPRATPCUI_STR-BASELINEHEATINGVALUE sy-vline
WA_IPRATPCUI_STR-ACTUALHEATINGVALUESTSCRITLTY sy-vline
WA_IPRATPCUI_STR-NMBROFDAYSPRODUCED sy-vline
WA_IPRATPCUI_STR-BSLNNMBROFDAYSPRODUCED sy-vline
WA_IPRATPCUI_STR-DAYSPRODUCEDSTSCRITLTY sy-vline
WA_IPRATPCUI_STR-MATERIAL sy-vline
WA_IPRATPCUI_STR-BASELINEMATERIAL sy-vline
WA_IPRATPCUI_STR-PRATSTMATERIALSTSCRITLTY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.