ABAP Select data from SAP table IPRATENTWCC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IPRATENTWCC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IPRATENTWCC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IPRATENTWCC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IPRATENTWCC TYPE STANDARD TABLE OF IPRATENTWCC,
      WA_IPRATENTWCC TYPE IPRATENTWCC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IPRATENTWCC> TYPE IPRATENTWCC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IPRATENTWCC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IPRATENTWCC
  INTO TABLE IT_IPRATENTWCC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IPRATENTWCC
*  INTO TABLE @DATA(IT_IPRATENTWCC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IPRATENTWCC INDEX 1 INTO DATA(WA_IPRATENTWCC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IPRATENTWCC ASSIGNING <IPRATENTWCC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IPRATENTWCC>-MANDT = 1.
<IPRATENTWCC>-DELIVERYNETWORK = 1.
<IPRATENTWCC>-MATERIAL = 1.
<IPRATENTWCC>-WELL = 1.
<IPRATENTWCC>-WELLCOMPLETION = 1.
ENDLOOP.

LOOP AT IT_IPRATENTWCC INTO WA_IPRATENTWCC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IPRATENTWCC-PROCESSINGCOMPANYCODE, sy-vline,
WA_IPRATENTWCC-PRAJOINTVENTURE, sy-vline,
WA_IPRATENTWCC-DIVISIONOFINTEREST, sy-vline,
WA_IPRATENTWCC-SALESDATE, sy-vline,
WA_IPRATENTWCC-ALLOCATIONFREQUENCY, sy-vline,
WA_IPRATENTWCC-VOLUMETYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IPRATENTWCC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IPRATENTWCC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IPRATENTWCC INTO WA_IPRATENTWCC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DELIVERYNETWORK CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATENTWCC-DELIVERYNETWORK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATENTWCC-DELIVERYNETWORK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IPRATENTWCC-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATENTWCC-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WELL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATENTWCC-WELL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATENTWCC-WELL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WELLCOMPLETION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATENTWCC-WELLCOMPLETION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATENTWCC-WELLCOMPLETION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRAJOINTVENTURE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATENTWCC-PRAJOINTVENTURE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATENTWCC-PRAJOINTVENTURE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DIVISIONOFINTEREST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATENTWCC-DIVISIONOFINTEREST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATENTWCC-DIVISIONOFINTEREST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRAOWNER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATENTWCC-PRAOWNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATENTWCC-PRAOWNER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OWNERINTERESTSEQUENCE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATENTWCC-OWNERINTERESTSEQUENCE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATENTWCC-OWNERINTERESTSEQUENCE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLUMEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPRATENTWCC-VOLUMEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATENTWCC-VOLUMEUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ENERGYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPRATENTWCC-ENERGYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATENTWCC-ENERGYUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BASELINEMARKETINGREP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATENTWCC-BASELINEMARKETINGREP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATENTWCC-BASELINEMARKETINGREP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MARKETINGREP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATENTWCC-MARKETINGREP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATENTWCC-MARKETINGREP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BSLNMKTREPINTRSTSEQUNMBR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATENTWCC-BSLNMKTREPINTRSTSEQUNMBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATENTWCC-BSLNMKTREPINTRSTSEQUNMBR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MARKETINGREPINTRSTSEQUNMBR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATENTWCC-MARKETINGREPINTRSTSEQUNMBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATENTWCC-MARKETINGREPINTRSTSEQUNMBR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IPRATENTWCC_STR,
MANDT TYPE STRING,
DELIVERYNETWORK TYPE STRING,
MATERIAL TYPE STRING,
WELL TYPE STRING,
WELLCOMPLETION TYPE STRING,
PROCESSINGCOMPANYCODE TYPE STRING,
PRAJOINTVENTURE TYPE STRING,
DIVISIONOFINTEREST TYPE STRING,
SALESDATE TYPE STRING,
ALLOCATIONFREQUENCY TYPE STRING,
VOLUMETYPE TYPE STRING,
PRAOWNER TYPE STRING,
OWNERINTERESTTYPE TYPE STRING,
OWNERINTERESTSEQUENCE TYPE STRING,
MAJORPRODUCT TYPE STRING,
VOLUMEUNIT TYPE STRING,
BASELINEENTITLEDVOLUME TYPE STRING,
ENTITLEDVOLUME TYPE STRING,
ENTITLEDVOLUMEDIFFVAL TYPE STRING,
ENERGYUNIT TYPE STRING,
BASELINEENTITLEDENERGY TYPE STRING,
ENTITLEDENERGY TYPE STRING,
ENTITLEDENERGYDIFFVAL TYPE STRING,
BASELINEADJUSTEDENTITLEDVOL TYPE STRING,
ADJUSTEDENTITLEDVOL TYPE STRING,
ADJUSTEDENTITLEDVOLDIFFVAL TYPE STRING,
BASELINEADJUSTEDENTITLEDENGY TYPE STRING,
ADJUSTEDENTITLEDENGY TYPE STRING,
ADJUSTEDENTITLEDENGYDIFFVAL TYPE STRING,
SEQUENCENUMBER TYPE STRING,
BASELINEMARKETINGREP TYPE STRING,
MARKETINGREP TYPE STRING,
BSLNMKTREPINTRSTSEQUNMBR TYPE STRING,
MARKETINGREPINTRSTSEQUNMBR TYPE STRING,
ENTITLEDVOLUMETOLVAL TYPE STRING,
ADJDENTITLEDVOLTOLVAL TYPE STRING,
ENTITLEDENERGYTOLVAL TYPE STRING,
ADJDENTITLEDENGYTOLVAL TYPE STRING,END OF T_EKKO_STR. DATA: WA_IPRATENTWCC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IPRATENTWCC_STR-MANDT sy-vline
WA_IPRATENTWCC_STR-DELIVERYNETWORK sy-vline
WA_IPRATENTWCC_STR-MATERIAL sy-vline
WA_IPRATENTWCC_STR-WELL sy-vline
WA_IPRATENTWCC_STR-WELLCOMPLETION sy-vline
WA_IPRATENTWCC_STR-PROCESSINGCOMPANYCODE sy-vline
WA_IPRATENTWCC_STR-PRAJOINTVENTURE sy-vline
WA_IPRATENTWCC_STR-DIVISIONOFINTEREST sy-vline
WA_IPRATENTWCC_STR-SALESDATE sy-vline
WA_IPRATENTWCC_STR-ALLOCATIONFREQUENCY sy-vline
WA_IPRATENTWCC_STR-VOLUMETYPE sy-vline
WA_IPRATENTWCC_STR-PRAOWNER sy-vline
WA_IPRATENTWCC_STR-OWNERINTERESTTYPE sy-vline
WA_IPRATENTWCC_STR-OWNERINTERESTSEQUENCE sy-vline
WA_IPRATENTWCC_STR-MAJORPRODUCT sy-vline
WA_IPRATENTWCC_STR-VOLUMEUNIT sy-vline
WA_IPRATENTWCC_STR-BASELINEENTITLEDVOLUME sy-vline
WA_IPRATENTWCC_STR-ENTITLEDVOLUME sy-vline
WA_IPRATENTWCC_STR-ENTITLEDVOLUMEDIFFVAL sy-vline
WA_IPRATENTWCC_STR-ENERGYUNIT sy-vline
WA_IPRATENTWCC_STR-BASELINEENTITLEDENERGY sy-vline
WA_IPRATENTWCC_STR-ENTITLEDENERGY sy-vline
WA_IPRATENTWCC_STR-ENTITLEDENERGYDIFFVAL sy-vline
WA_IPRATENTWCC_STR-BASELINEADJUSTEDENTITLEDVOL sy-vline
WA_IPRATENTWCC_STR-ADJUSTEDENTITLEDVOL sy-vline
WA_IPRATENTWCC_STR-ADJUSTEDENTITLEDVOLDIFFVAL sy-vline
WA_IPRATENTWCC_STR-BASELINEADJUSTEDENTITLEDENGY sy-vline
WA_IPRATENTWCC_STR-ADJUSTEDENTITLEDENGY sy-vline
WA_IPRATENTWCC_STR-ADJUSTEDENTITLEDENGYDIFFVAL sy-vline
WA_IPRATENTWCC_STR-SEQUENCENUMBER sy-vline
WA_IPRATENTWCC_STR-BASELINEMARKETINGREP sy-vline
WA_IPRATENTWCC_STR-MARKETINGREP sy-vline
WA_IPRATENTWCC_STR-BSLNMKTREPINTRSTSEQUNMBR sy-vline
WA_IPRATENTWCC_STR-MARKETINGREPINTRSTSEQUNMBR sy-vline
WA_IPRATENTWCC_STR-ENTITLEDVOLUMETOLVAL sy-vline
WA_IPRATENTWCC_STR-ADJDENTITLEDVOLTOLVAL sy-vline
WA_IPRATENTWCC_STR-ENTITLEDENERGYTOLVAL sy-vline
WA_IPRATENTWCC_STR-ADJDENTITLEDENGYTOLVAL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.