ABAP Select data from SAP table IPRATACTWCC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IPRATACTWCC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IPRATACTWCC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IPRATACTWCC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IPRATACTWCC TYPE STANDARD TABLE OF IPRATACTWCC,
      WA_IPRATACTWCC TYPE IPRATACTWCC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IPRATACTWCC> TYPE IPRATACTWCC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IPRATACTWCC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IPRATACTWCC
  INTO TABLE IT_IPRATACTWCC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IPRATACTWCC
*  INTO TABLE @DATA(IT_IPRATACTWCC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IPRATACTWCC INDEX 1 INTO DATA(WA_IPRATACTWCC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IPRATACTWCC ASSIGNING <IPRATACTWCC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IPRATACTWCC>-MANDT = 1.
<IPRATACTWCC>-PRATSTALLOCVERSION = 1.
<IPRATACTWCC>-DELIVERYNETWORK = 1.
<IPRATACTWCC>-WELL = 1.
<IPRATACTWCC>-WELLCOMPLETION = 1.
ENDLOOP.

LOOP AT IT_IPRATACTWCC INTO WA_IPRATACTWCC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IPRATACTWCC-MATERIAL, sy-vline,
WA_IPRATACTWCC-PRACONTRACT, sy-vline,
WA_IPRATACTWCC-SALESDATE, sy-vline,
WA_IPRATACTWCC-PRAOWNER, sy-vline,
WA_IPRATACTWCC-OWNERINTERESTTYPE, sy-vline,
WA_IPRATACTWCC-OWNERINTERESTSEQUENCE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IPRATACTWCC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IPRATACTWCC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IPRATACTWCC INTO WA_IPRATACTWCC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DELIVERYNETWORK CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATACTWCC-DELIVERYNETWORK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATACTWCC-DELIVERYNETWORK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WELL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATACTWCC-WELL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATACTWCC-WELL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WELLCOMPLETION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATACTWCC-WELLCOMPLETION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATACTWCC-WELLCOMPLETION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IPRATACTWCC-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATACTWCC-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRACONTRACT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATACTWCC-PRACONTRACT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATACTWCC-PRACONTRACT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRAOWNER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATACTWCC-PRAOWNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATACTWCC-PRAOWNER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OWNERINTERESTSEQUENCE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATACTWCC-OWNERINTERESTSEQUENCE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATACTWCC-OWNERINTERESTSEQUENCE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ORIGINATINGMEASUREMENTPT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATACTWCC-ORIGINATINGMEASUREMENTPT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATACTWCC-ORIGINATINGMEASUREMENTPT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRANSPORTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IPRATACTWCC-TRANSPORTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATACTWCC-TRANSPORTER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLUMEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPRATACTWCC-VOLUMEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATACTWCC-VOLUMEUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field HEATINGVALUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPRATACTWCC-HEATINGVALUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATACTWCC-HEATINGVALUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ENERGYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPRATACTWCC-ENERGYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPRATACTWCC-ENERGYUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IPRATACTWCC_STR,
MANDT TYPE STRING,
PRATSTALLOCVERSION TYPE STRING,
DELIVERYNETWORK TYPE STRING,
WELL TYPE STRING,
WELLCOMPLETION TYPE STRING,
MATERIAL TYPE STRING,
PRACONTRACT TYPE STRING,
SALESDATE TYPE STRING,
PRAOWNER TYPE STRING,
OWNERINTERESTTYPE TYPE STRING,
OWNERINTERESTSEQUENCE TYPE STRING,
ORIGINATINGMEASUREMENTPT TYPE STRING,
TRANSPORTER TYPE STRING,
ALLOCATIONFREQUENCY TYPE STRING,
MAJORPRODUCT TYPE STRING,
BASELINEACTUALVOLUME TYPE STRING,
ACTUALVOLUME TYPE STRING,
ACTUALVOLUMEDIFFPCT TYPE STRING,
VOLUMEUNIT TYPE STRING,
BASELINEACTUALHEATINGVALUE TYPE STRING,
ACTUALHEATINGVALUE TYPE STRING,
ACTUALHEATINGVALUEDIFFVAL TYPE STRING,
HEATINGVALUNIT TYPE STRING,
BASELINEACTUALENERGY TYPE STRING,
ACTUALENERGY TYPE STRING,
ACTUALENERGYDIFFVAL TYPE STRING,
ENERGYUNIT TYPE STRING,
BASELINEWETGASOVERRIDEPCT TYPE STRING,
WETGASOVERRIDEPCT TYPE STRING,
WETGASOVERRIDEPCTDIFFVAL TYPE STRING,
BASELINEENTITLEDVOLUME TYPE STRING,
ENTITLEDVOLUME TYPE STRING,
ENTITLEDVOLUMEDIFFVAL TYPE STRING,
BASELINEADJUSTEDENTITLEDVOL TYPE STRING,
ADJUSTEDENTITLEDVOL TYPE STRING,
ADJUSTEDENTITLEDVOLDIFFVAL TYPE STRING,
BASELINEENTITLEDENERGY TYPE STRING,
ENTITLEDENERGY TYPE STRING,
ENTITLEDENERGYDIFFVAL TYPE STRING,
BASELINEADJUSTEDENTITLEDENGY TYPE STRING,
ADJUSTEDENTITLEDENGY TYPE STRING,
ADJUSTEDENTITLEDENGYDIFFVAL TYPE STRING,
CREATEDBYUSER TYPE STRING,
CREATIONDATETIME TYPE STRING,
SEQUENCENUMBER TYPE STRING,
ACTUALVOLUMETOLERANCEINPCT TYPE STRING,
ACTLHEATVALTOLERANCEVAL TYPE STRING,
ACTUALENGYTOLERANCEVAL TYPE STRING,
ENTITLEDVOLUMETOLVAL TYPE STRING,
ADJDENTITLEDVOLTOLVAL TYPE STRING,
ENTITLEDENERGYTOLVAL TYPE STRING,
ADJDENTITLEDENGYTOLVAL TYPE STRING,END OF T_EKKO_STR. DATA: WA_IPRATACTWCC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IPRATACTWCC_STR-MANDT sy-vline
WA_IPRATACTWCC_STR-PRATSTALLOCVERSION sy-vline
WA_IPRATACTWCC_STR-DELIVERYNETWORK sy-vline
WA_IPRATACTWCC_STR-WELL sy-vline
WA_IPRATACTWCC_STR-WELLCOMPLETION sy-vline
WA_IPRATACTWCC_STR-MATERIAL sy-vline
WA_IPRATACTWCC_STR-PRACONTRACT sy-vline
WA_IPRATACTWCC_STR-SALESDATE sy-vline
WA_IPRATACTWCC_STR-PRAOWNER sy-vline
WA_IPRATACTWCC_STR-OWNERINTERESTTYPE sy-vline
WA_IPRATACTWCC_STR-OWNERINTERESTSEQUENCE sy-vline
WA_IPRATACTWCC_STR-ORIGINATINGMEASUREMENTPT sy-vline
WA_IPRATACTWCC_STR-TRANSPORTER sy-vline
WA_IPRATACTWCC_STR-ALLOCATIONFREQUENCY sy-vline
WA_IPRATACTWCC_STR-MAJORPRODUCT sy-vline
WA_IPRATACTWCC_STR-BASELINEACTUALVOLUME sy-vline
WA_IPRATACTWCC_STR-ACTUALVOLUME sy-vline
WA_IPRATACTWCC_STR-ACTUALVOLUMEDIFFPCT sy-vline
WA_IPRATACTWCC_STR-VOLUMEUNIT sy-vline
WA_IPRATACTWCC_STR-BASELINEACTUALHEATINGVALUE sy-vline
WA_IPRATACTWCC_STR-ACTUALHEATINGVALUE sy-vline
WA_IPRATACTWCC_STR-ACTUALHEATINGVALUEDIFFVAL sy-vline
WA_IPRATACTWCC_STR-HEATINGVALUNIT sy-vline
WA_IPRATACTWCC_STR-BASELINEACTUALENERGY sy-vline
WA_IPRATACTWCC_STR-ACTUALENERGY sy-vline
WA_IPRATACTWCC_STR-ACTUALENERGYDIFFVAL sy-vline
WA_IPRATACTWCC_STR-ENERGYUNIT sy-vline
WA_IPRATACTWCC_STR-BASELINEWETGASOVERRIDEPCT sy-vline
WA_IPRATACTWCC_STR-WETGASOVERRIDEPCT sy-vline
WA_IPRATACTWCC_STR-WETGASOVERRIDEPCTDIFFVAL sy-vline
WA_IPRATACTWCC_STR-BASELINEENTITLEDVOLUME sy-vline
WA_IPRATACTWCC_STR-ENTITLEDVOLUME sy-vline
WA_IPRATACTWCC_STR-ENTITLEDVOLUMEDIFFVAL sy-vline
WA_IPRATACTWCC_STR-BASELINEADJUSTEDENTITLEDVOL sy-vline
WA_IPRATACTWCC_STR-ADJUSTEDENTITLEDVOL sy-vline
WA_IPRATACTWCC_STR-ADJUSTEDENTITLEDVOLDIFFVAL sy-vline
WA_IPRATACTWCC_STR-BASELINEENTITLEDENERGY sy-vline
WA_IPRATACTWCC_STR-ENTITLEDENERGY sy-vline
WA_IPRATACTWCC_STR-ENTITLEDENERGYDIFFVAL sy-vline
WA_IPRATACTWCC_STR-BASELINEADJUSTEDENTITLEDENGY sy-vline
WA_IPRATACTWCC_STR-ADJUSTEDENTITLEDENGY sy-vline
WA_IPRATACTWCC_STR-ADJUSTEDENTITLEDENGYDIFFVAL sy-vline
WA_IPRATACTWCC_STR-CREATEDBYUSER sy-vline
WA_IPRATACTWCC_STR-CREATIONDATETIME sy-vline
WA_IPRATACTWCC_STR-SEQUENCENUMBER sy-vline
WA_IPRATACTWCC_STR-ACTUALVOLUMETOLERANCEINPCT sy-vline
WA_IPRATACTWCC_STR-ACTLHEATVALTOLERANCEVAL sy-vline
WA_IPRATACTWCC_STR-ACTUALENGYTOLERANCEVAL sy-vline
WA_IPRATACTWCC_STR-ENTITLEDVOLUMETOLVAL sy-vline
WA_IPRATACTWCC_STR-ADJDENTITLEDVOLTOLVAL sy-vline
WA_IPRATACTWCC_STR-ENTITLEDENERGYTOLVAL sy-vline
WA_IPRATACTWCC_STR-ADJDENTITLEDENGYTOLVAL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.