ABAP Select data from SAP table IPHYINVGRFLD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IPHYINVGRFLD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IPHYINVGRFLD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IPHYINVGRFLD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IPHYINVGRFLD TYPE STANDARD TABLE OF IPHYINVGRFLD,
      WA_IPHYINVGRFLD TYPE IPHYINVGRFLD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IPHYINVGRFLD> TYPE IPHYINVGRFLD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IPHYINVGRFLD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IPHYINVGRFLD
  INTO TABLE IT_IPHYINVGRFLD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IPHYINVGRFLD
*  INTO TABLE @DATA(IT_IPHYINVGRFLD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IPHYINVGRFLD INDEX 1 INTO DATA(WA_IPHYINVGRFLD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IPHYINVGRFLD ASSIGNING <IPHYINVGRFLD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IPHYINVGRFLD>-MANDT = 1.
<IPHYINVGRFLD>-STORAGEOBJSGMNTNMBR = 1.
<IPHYINVGRFLD>-OPENTANKDIPTIME = 1.
<IPHYINVGRFLD>-EVENTSINSILOTANKDIP = 1.
<IPHYINVGRFLD>-RELTDBOOKSTKTANKDIPQTY = 1.
ENDLOOP.

LOOP AT IT_IPHYINVGRFLD INTO WA_IPHYINVGRFLD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IPHYINVGRFLD-OILLINEARVOLCNVRSNSETNMBR, sy-vline,
WA_IPHYINVGRFLD-RECALIBRATIONINDEX, sy-vline,
WA_IPHYINVGRFLD-TANKDIPTOTALHEIGHT, sy-vline,
WA_IPHYINVGRFLD-TANKDIPTOTALHEIGHTUOM, sy-vline,
WA_IPHYINVGRFLD-TANKDIPWATERHEIGHT, sy-vline,
WA_IPHYINVGRFLD-TANKDIPWATERHEIGHTUOM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IPHYINVGRFLD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IPHYINVGRFLD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IPHYINVGRFLD INTO WA_IPHYINVGRFLD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field TANKDIPTOTALHEIGHTUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPHYINVGRFLD-TANKDIPTOTALHEIGHTUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPHYINVGRFLD-TANKDIPTOTALHEIGHTUOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field TANKDIPWATERHEIGHTUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPHYINVGRFLD-TANKDIPWATERHEIGHTUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPHYINVGRFLD-TANKDIPWATERHEIGHTUOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPHYINVGRFLD-BASEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPHYINVGRFLD-BASEUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LINEARVOLCNVRSNUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPHYINVGRFLD-LINEARVOLCNVRSNUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPHYINVGRFLD-LINEARVOLCNVRSNUOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IPHYINVGRFLD_STR,
MANDT TYPE STRING,
STORAGEOBJSGMNTNMBR TYPE STRING,
OPENTANKDIPTIME TYPE STRING,
EVENTSINSILOTANKDIP TYPE STRING,
RELTDBOOKSTKTANKDIPQTY TYPE STRING,
OILLINEARVOLCNVRSNSETNMBR TYPE STRING,
RECALIBRATIONINDEX TYPE STRING,
TANKDIPTOTALHEIGHT TYPE STRING,
TANKDIPTOTALHEIGHTUOM TYPE STRING,
TANKDIPWATERHEIGHT TYPE STRING,
TANKDIPWATERHEIGHTUOM TYPE STRING,
TANKDIPQTYSTKKEEPINGUNIT TYPE STRING,
BASEUNIT TYPE STRING,
LINEARVOLMATERIALQTY TYPE STRING,
LINEARVOLWATERQTY TYPE STRING,
DIPPINGMETHODINNAGEULLAGE TYPE STRING,
LINEARVOLCNVRSNUOM TYPE STRING,
DIPGUID TYPE STRING,
OILTANKDIPCREATEDATE TYPE STRING,
OILTANKDIPCREATETIME TYPE STRING,
CREATEDBYUSER TYPE STRING,
OILTANKDIPCHANGEDATE TYPE STRING,
OILTANKDIPCHANGETIME TYPE STRING,
OILTANKDIPCHANGEDBYUSER TYPE STRING,
ISTANKDIPBLOCKED TYPE STRING,
ISDELETED TYPE STRING,
TANKDIPTOTALHEIGHTFLTP TYPE STRING,
TANKDIPWATERHEIGHTFLTP TYPE STRING,
TANKDIPTOTALHEIGHTSTRING TYPE STRING,
TANKDIPWATERHEIGHTSTRING TYPE STRING,
ISRECONCILIATIONCOMPLETION TYPE STRING,
OILTIMESTAMPDISPLAY TYPE STRING,
STARTDATE TYPE STRING,
OPENTANKDIPTIMEDCML TYPE STRING,
CURRENTSYSTEMUTCDATETIME TYPE STRING,
MATERIALDESCRIPTION TYPE STRING,END OF T_EKKO_STR. DATA: WA_IPHYINVGRFLD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IPHYINVGRFLD_STR-MANDT sy-vline
WA_IPHYINVGRFLD_STR-STORAGEOBJSGMNTNMBR sy-vline
WA_IPHYINVGRFLD_STR-OPENTANKDIPTIME sy-vline
WA_IPHYINVGRFLD_STR-EVENTSINSILOTANKDIP sy-vline
WA_IPHYINVGRFLD_STR-RELTDBOOKSTKTANKDIPQTY sy-vline
WA_IPHYINVGRFLD_STR-OILLINEARVOLCNVRSNSETNMBR sy-vline
WA_IPHYINVGRFLD_STR-RECALIBRATIONINDEX sy-vline
WA_IPHYINVGRFLD_STR-TANKDIPTOTALHEIGHT sy-vline
WA_IPHYINVGRFLD_STR-TANKDIPTOTALHEIGHTUOM sy-vline
WA_IPHYINVGRFLD_STR-TANKDIPWATERHEIGHT sy-vline
WA_IPHYINVGRFLD_STR-TANKDIPWATERHEIGHTUOM sy-vline
WA_IPHYINVGRFLD_STR-TANKDIPQTYSTKKEEPINGUNIT sy-vline
WA_IPHYINVGRFLD_STR-BASEUNIT sy-vline
WA_IPHYINVGRFLD_STR-LINEARVOLMATERIALQTY sy-vline
WA_IPHYINVGRFLD_STR-LINEARVOLWATERQTY sy-vline
WA_IPHYINVGRFLD_STR-DIPPINGMETHODINNAGEULLAGE sy-vline
WA_IPHYINVGRFLD_STR-LINEARVOLCNVRSNUOM sy-vline
WA_IPHYINVGRFLD_STR-DIPGUID sy-vline
WA_IPHYINVGRFLD_STR-OILTANKDIPCREATEDATE sy-vline
WA_IPHYINVGRFLD_STR-OILTANKDIPCREATETIME sy-vline
WA_IPHYINVGRFLD_STR-CREATEDBYUSER sy-vline
WA_IPHYINVGRFLD_STR-OILTANKDIPCHANGEDATE sy-vline
WA_IPHYINVGRFLD_STR-OILTANKDIPCHANGETIME sy-vline
WA_IPHYINVGRFLD_STR-OILTANKDIPCHANGEDBYUSER sy-vline
WA_IPHYINVGRFLD_STR-ISTANKDIPBLOCKED sy-vline
WA_IPHYINVGRFLD_STR-ISDELETED sy-vline
WA_IPHYINVGRFLD_STR-TANKDIPTOTALHEIGHTFLTP sy-vline
WA_IPHYINVGRFLD_STR-TANKDIPWATERHEIGHTFLTP sy-vline
WA_IPHYINVGRFLD_STR-TANKDIPTOTALHEIGHTSTRING sy-vline
WA_IPHYINVGRFLD_STR-TANKDIPWATERHEIGHTSTRING sy-vline
WA_IPHYINVGRFLD_STR-ISRECONCILIATIONCOMPLETION sy-vline
WA_IPHYINVGRFLD_STR-OILTIMESTAMPDISPLAY sy-vline
WA_IPHYINVGRFLD_STR-STARTDATE sy-vline
WA_IPHYINVGRFLD_STR-OPENTANKDIPTIMEDCML sy-vline
WA_IPHYINVGRFLD_STR-CURRENTSYSTEMUTCDATETIME sy-vline
WA_IPHYINVGRFLD_STR-MATERIALDESCRIPTION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.