ABAP Select data from SAP table IPHFLOWTIMTP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IPHFLOWTIMTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IPHFLOWTIMTP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IPHFLOWTIMTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IPHFLOWTIMTP TYPE STANDARD TABLE OF IPHFLOWTIMTP,
      WA_IPHFLOWTIMTP TYPE IPHFLOWTIMTP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IPHFLOWTIMTP> TYPE IPHFLOWTIMTP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IPHFLOWTIMTP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IPHFLOWTIMTP
  INTO TABLE IT_IPHFLOWTIMTP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IPHFLOWTIMTP
*  INTO TABLE @DATA(IT_IPHFLOWTIMTP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IPHFLOWTIMTP INDEX 1 INTO DATA(WA_IPHFLOWTIMTP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IPHFLOWTIMTP ASSIGNING <IPHFLOWTIMTP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IPHFLOWTIMTP>-MANDT = 1.
<IPHFLOWTIMTP>-PHYSCHMLFLWTMEUUID = 1.
<IPHFLOWTIMTP>-PHYSCHMLPRPTYUUID = 1.
<IPHFLOWTIMTP>-CREATIONUTCDATETIME = 1.
<IPHFLOWTIMTP>-CREATEDBYUSER = 1.
ENDLOOP.

LOOP AT IT_IPHFLOWTIMTP INTO WA_IPHFLOWTIMTP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IPHFLOWTIMTP-LASTCHANGEUTCDATETIME, sy-vline,
WA_IPHFLOWTIMTP-LASTCHANGEDBYUSER, sy-vline,
WA_IPHFLOWTIMTP-PCPRPTYLOWRLMTOPTR, sy-vline,
WA_IPHFLOWTIMTP-PCPHYSFLWTMELOWRQTY, sy-vline,
WA_IPHFLOWTIMTP-PCPHYSFLWTMELOWRQTYASTXT, sy-vline,
WA_IPHFLOWTIMTP-PCPRPTYUPRLMTOPTR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IPHFLOWTIMTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IPHFLOWTIMTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IPHFLOWTIMTP INTO WA_IPHFLOWTIMTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field PHYSCHMLFLWTMEQTYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPHFLOWTIMTP-PHYSCHMLFLWTMEQTYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPHFLOWTIMTP-PHYSCHMLFLWTMEQTYUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PCPHYSFLWTMECRSSCTNQTYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPHFLOWTIMTP-PCPHYSFLWTMECRSSCTNQTYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPHFLOWTIMTP-PCPHYSFLWTMECRSSCTNQTYUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IPHFLOWTIMTP_STR,
MANDT TYPE STRING,
PHYSCHMLFLWTMEUUID TYPE STRING,
PHYSCHMLPRPTYUUID TYPE STRING,
CREATIONUTCDATETIME TYPE STRING,
CREATEDBYUSER TYPE STRING,
LASTCHANGEUTCDATETIME TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
PCPRPTYLOWRLMTOPTR TYPE STRING,
PCPHYSFLWTMELOWRQTY TYPE STRING,
PCPHYSFLWTMELOWRQTYASTXT TYPE STRING,
PCPRPTYUPRLMTOPTR TYPE STRING,
PCPHYSFLWTMEUPRQTY TYPE STRING,
PCPHYSFLWTMEUPRQTYASTXT TYPE STRING,
PHYSCHMLFLWTMEQTYUNIT TYPE STRING,
PCPHYSFLWTMEMETHODPHRSUUID TYPE STRING,
PCPHYSFLWTMECRSSCTNQTYASTXT TYPE STRING,
PCPHYSFLWTMECRSSCTNQTY TYPE STRING,
PCPHYSFLWTMECRSSCTNQTYUNIT TYPE STRING,
PCPHYSNOTETEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_IPHFLOWTIMTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IPHFLOWTIMTP_STR-MANDT sy-vline
WA_IPHFLOWTIMTP_STR-PHYSCHMLFLWTMEUUID sy-vline
WA_IPHFLOWTIMTP_STR-PHYSCHMLPRPTYUUID sy-vline
WA_IPHFLOWTIMTP_STR-CREATIONUTCDATETIME sy-vline
WA_IPHFLOWTIMTP_STR-CREATEDBYUSER sy-vline
WA_IPHFLOWTIMTP_STR-LASTCHANGEUTCDATETIME sy-vline
WA_IPHFLOWTIMTP_STR-LASTCHANGEDBYUSER sy-vline
WA_IPHFLOWTIMTP_STR-PCPRPTYLOWRLMTOPTR sy-vline
WA_IPHFLOWTIMTP_STR-PCPHYSFLWTMELOWRQTY sy-vline
WA_IPHFLOWTIMTP_STR-PCPHYSFLWTMELOWRQTYASTXT sy-vline
WA_IPHFLOWTIMTP_STR-PCPRPTYUPRLMTOPTR sy-vline
WA_IPHFLOWTIMTP_STR-PCPHYSFLWTMEUPRQTY sy-vline
WA_IPHFLOWTIMTP_STR-PCPHYSFLWTMEUPRQTYASTXT sy-vline
WA_IPHFLOWTIMTP_STR-PHYSCHMLFLWTMEQTYUNIT sy-vline
WA_IPHFLOWTIMTP_STR-PCPHYSFLWTMEMETHODPHRSUUID sy-vline
WA_IPHFLOWTIMTP_STR-PCPHYSFLWTMECRSSCTNQTYASTXT sy-vline
WA_IPHFLOWTIMTP_STR-PCPHYSFLWTMECRSSCTNQTY sy-vline
WA_IPHFLOWTIMTP_STR-PCPHYSFLWTMECRSSCTNQTYUNIT sy-vline
WA_IPHFLOWTIMTP_STR-PCPHYSNOTETEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.