ABAP Select data from SAP table IPCECTXSTBW into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IPCECTXSTBW table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IPCECTXSTBW. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IPCECTXSTBW table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IPCECTXSTBW TYPE STANDARD TABLE OF IPCECTXSTBW,
      WA_IPCECTXSTBW TYPE IPCECTXSTBW,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IPCECTXSTBW> TYPE IPCECTXSTBW.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IPCECTXSTBW.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IPCECTXSTBW
  INTO TABLE IT_IPCECTXSTBW.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IPCECTXSTBW
*  INTO TABLE @DATA(IT_IPCECTXSTBW2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IPCECTXSTBW INDEX 1 INTO DATA(WA_IPCECTXSTBW2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IPCECTXSTBW ASSIGNING <IPCECTXSTBW>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IPCECTXSTBW>-MANDT = 1.
<IPCECTXSTBW>-PCECTXSTBLTYWATERPRPTYUUID = 1.
<IPCECTXSTBW>-PCECTXPRPTYUUID = 1.
<IPCECTXSTBW>-PCECTXPHSCALELOWRVAL = 1.
<IPCECTXSTBW>-PCECTXPHSCALELOWRVALTXT = 1.
ENDLOOP.

LOOP AT IT_IPCECTXSTBW INTO WA_IPCECTXSTBW.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IPCECTXSTBW-PCECTXPHSCALELOWRVALOPTR, sy-vline,
WA_IPCECTXSTBW-PCECTXPHSCALEUPRVAL, sy-vline,
WA_IPCECTXSTBW-PCECTXPHSCALEUPRVALTXT, sy-vline,
WA_IPCECTXSTBW-PCECTXPHSCALEUPRVALOPTR, sy-vline,
WA_IPCECTXSTBW-PCECTXSTBLTYWATERTEMPQTY, sy-vline,
WA_IPCECTXSTBW-PCECTXSTBLTYWATERTEMPQTYTXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IPCECTXSTBW you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IPCECTXSTBW TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IPCECTXSTBW INTO WA_IPCECTXSTBW. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field PCECTXSTBLTYWATERTEMPQTYUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPCECTXSTBW-PCECTXSTBLTYWATERTEMPQTYUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPCECTXSTBW-PCECTXSTBLTYWATERTEMPQTYUOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PCECTXHALFLIFEUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPCECTXSTBW-PCECTXHALFLIFEUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPCECTXSTBW-PCECTXHALFLIFEUOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IPCECTXSTBW_STR,
MANDT TYPE STRING,
PCECTXSTBLTYWATERPRPTYUUID TYPE STRING,
PCECTXPRPTYUUID TYPE STRING,
PCECTXPHSCALELOWRVAL TYPE STRING,
PCECTXPHSCALELOWRVALTXT TYPE STRING,
PCECTXPHSCALELOWRVALOPTR TYPE STRING,
PCECTXPHSCALEUPRVAL TYPE STRING,
PCECTXPHSCALEUPRVALTXT TYPE STRING,
PCECTXPHSCALEUPRVALOPTR TYPE STRING,
PCECTXSTBLTYWATERTEMPQTY TYPE STRING,
PCECTXSTBLTYWATERTEMPQTYTXT TYPE STRING,
PCECTXSTBLTYWATERTEMPQTYUOM TYPE STRING,
PCECTXHALFLIFELOWRDURN TYPE STRING,
PCECTXHALFLIFELOWRDURNTXT TYPE STRING,
PCECTXHALFLIFELOWRDURNOPTR TYPE STRING,
PCECTXHALFLIFEUPRDURN TYPE STRING,
PCECTXHALFLIFEUPRDURNTXT TYPE STRING,
PCECTXHALFLIFEUPRDURNOPTR TYPE STRING,
PCECTXHALFLIFEUOM TYPE STRING,
PCECTXMETHODPHRSUUID TYPE STRING,
PCECTXNOTETEXT TYPE STRING,
PCECTXRATING TYPE STRING,
PCECTXADDLSTATEMENTPHRSUUID TYPE STRING,
PCECTXASSMTPHRSUUID TYPE STRING,
CREATIONUTCDATETIME TYPE STRING,
CREATEDBYUSER TYPE STRING,
LASTCHANGEUTCDATETIME TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,END OF T_EKKO_STR. DATA: WA_IPCECTXSTBW_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IPCECTXSTBW_STR-MANDT sy-vline
WA_IPCECTXSTBW_STR-PCECTXSTBLTYWATERPRPTYUUID sy-vline
WA_IPCECTXSTBW_STR-PCECTXPRPTYUUID sy-vline
WA_IPCECTXSTBW_STR-PCECTXPHSCALELOWRVAL sy-vline
WA_IPCECTXSTBW_STR-PCECTXPHSCALELOWRVALTXT sy-vline
WA_IPCECTXSTBW_STR-PCECTXPHSCALELOWRVALOPTR sy-vline
WA_IPCECTXSTBW_STR-PCECTXPHSCALEUPRVAL sy-vline
WA_IPCECTXSTBW_STR-PCECTXPHSCALEUPRVALTXT sy-vline
WA_IPCECTXSTBW_STR-PCECTXPHSCALEUPRVALOPTR sy-vline
WA_IPCECTXSTBW_STR-PCECTXSTBLTYWATERTEMPQTY sy-vline
WA_IPCECTXSTBW_STR-PCECTXSTBLTYWATERTEMPQTYTXT sy-vline
WA_IPCECTXSTBW_STR-PCECTXSTBLTYWATERTEMPQTYUOM sy-vline
WA_IPCECTXSTBW_STR-PCECTXHALFLIFELOWRDURN sy-vline
WA_IPCECTXSTBW_STR-PCECTXHALFLIFELOWRDURNTXT sy-vline
WA_IPCECTXSTBW_STR-PCECTXHALFLIFELOWRDURNOPTR sy-vline
WA_IPCECTXSTBW_STR-PCECTXHALFLIFEUPRDURN sy-vline
WA_IPCECTXSTBW_STR-PCECTXHALFLIFEUPRDURNTXT sy-vline
WA_IPCECTXSTBW_STR-PCECTXHALFLIFEUPRDURNOPTR sy-vline
WA_IPCECTXSTBW_STR-PCECTXHALFLIFEUOM sy-vline
WA_IPCECTXSTBW_STR-PCECTXMETHODPHRSUUID sy-vline
WA_IPCECTXSTBW_STR-PCECTXNOTETEXT sy-vline
WA_IPCECTXSTBW_STR-PCECTXRATING sy-vline
WA_IPCECTXSTBW_STR-PCECTXADDLSTATEMENTPHRSUUID sy-vline
WA_IPCECTXSTBW_STR-PCECTXASSMTPHRSUUID sy-vline
WA_IPCECTXSTBW_STR-CREATIONUTCDATETIME sy-vline
WA_IPCECTXSTBW_STR-CREATEDBYUSER sy-vline
WA_IPCECTXSTBW_STR-LASTCHANGEUTCDATETIME sy-vline
WA_IPCECTXSTBW_STR-LASTCHANGEDBYUSER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.