ABAP Select data from SAP table IPCECTXAFISHTP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IPCECTXAFISHTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IPCECTXAFISHTP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IPCECTXAFISHTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IPCECTXAFISHTP TYPE STANDARD TABLE OF IPCECTXAFISHTP,
      WA_IPCECTXAFISHTP TYPE IPCECTXAFISHTP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IPCECTXAFISHTP> TYPE IPCECTXAFISHTP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IPCECTXAFISHTP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IPCECTXAFISHTP
  INTO TABLE IT_IPCECTXAFISHTP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IPCECTXAFISHTP
*  INTO TABLE @DATA(IT_IPCECTXAFISHTP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IPCECTXAFISHTP INDEX 1 INTO DATA(WA_IPCECTXAFISHTP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IPCECTXAFISHTP ASSIGNING <IPCECTXAFISHTP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IPCECTXAFISHTP>-MANDT = 1.
<IPCECTXAFISHTP>-PCECTXACUTEFISHUUID = 1.
<IPCECTXAFISHTP>-PCECTXPRPTYUUID = 1.
<IPCECTXAFISHTP>-PCECTXSPECIESPHRSUUID = 1.
<IPCECTXAFISHTP>-PCECTXEXPSRDURN = 1.
ENDLOOP.

LOOP AT IT_IPCECTXAFISHTP INTO WA_IPCECTXAFISHTP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IPCECTXAFISHTP-PCECTXEXPSRDURNASTEXT, sy-vline,
WA_IPCECTXAFISHTP-PCECTXEXPSRUOM, sy-vline,
WA_IPCECTXAFISHTP-PCECTXVALUETYPEPHRSUUID, sy-vline,
WA_IPCECTXAFISHTP-PCECTXVALUELOWRQTY, sy-vline,
WA_IPCECTXAFISHTP-PCECTXVALUELOWRQTYTXT, sy-vline,
WA_IPCECTXAFISHTP-PCECTXVALUELOWRQTYOPTR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IPCECTXAFISHTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IPCECTXAFISHTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IPCECTXAFISHTP INTO WA_IPCECTXAFISHTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field PCECTXEXPSRUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPCECTXAFISHTP-PCECTXEXPSRUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPCECTXAFISHTP-PCECTXEXPSRUOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PCECTXVALUEUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IPCECTXAFISHTP-PCECTXVALUEUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IPCECTXAFISHTP-PCECTXVALUEUOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IPCECTXAFISHTP_STR,
MANDT TYPE STRING,
PCECTXACUTEFISHUUID TYPE STRING,
PCECTXPRPTYUUID TYPE STRING,
PCECTXSPECIESPHRSUUID TYPE STRING,
PCECTXEXPSRDURN TYPE STRING,
PCECTXEXPSRDURNASTEXT TYPE STRING,
PCECTXEXPSRUOM TYPE STRING,
PCECTXVALUETYPEPHRSUUID TYPE STRING,
PCECTXVALUELOWRQTY TYPE STRING,
PCECTXVALUELOWRQTYTXT TYPE STRING,
PCECTXVALUELOWRQTYOPTR TYPE STRING,
PCECTXVALUEUPRQTY TYPE STRING,
PCECTXVALUEUPRQTYTXT TYPE STRING,
PCECTXVALUEUPRQTYOPTR TYPE STRING,
PCECTXVALUEUOM TYPE STRING,
PCECTXMETHODPHRSUUID TYPE STRING,
PCECTXNOTETEXT TYPE STRING,
PCECTXRATING TYPE STRING,
PCECTXADDLSTATEMENTPHRSUUID TYPE STRING,
PCECTXASSMTPHRSUUID TYPE STRING,
CREATIONUTCDATETIME TYPE STRING,
CREATEDBYUSER TYPE STRING,
LASTCHANGEUTCDATETIME TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,END OF T_EKKO_STR. DATA: WA_IPCECTXAFISHTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IPCECTXAFISHTP_STR-MANDT sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXACUTEFISHUUID sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXPRPTYUUID sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXSPECIESPHRSUUID sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXEXPSRDURN sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXEXPSRDURNASTEXT sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXEXPSRUOM sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXVALUETYPEPHRSUUID sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXVALUELOWRQTY sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXVALUELOWRQTYTXT sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXVALUELOWRQTYOPTR sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXVALUEUPRQTY sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXVALUEUPRQTYTXT sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXVALUEUPRQTYOPTR sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXVALUEUOM sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXMETHODPHRSUUID sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXNOTETEXT sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXRATING sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXADDLSTATEMENTPHRSUUID sy-vline
WA_IPCECTXAFISHTP_STR-PCECTXASSMTPHRSUUID sy-vline
WA_IPCECTXAFISHTP_STR-CREATIONUTCDATETIME sy-vline
WA_IPCECTXAFISHTP_STR-CREATEDBYUSER sy-vline
WA_IPCECTXAFISHTP_STR-LASTCHANGEUTCDATETIME sy-vline
WA_IPCECTXAFISHTP_STR-LASTCHANGEDBYUSER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.