ABAP Select data from SAP table IOPACTYASSGMT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IOPACTYASSGMT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IOPACTYASSGMT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IOPACTYASSGMT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IOPACTYASSGMT TYPE STANDARD TABLE OF IOPACTYASSGMT,
      WA_IOPACTYASSGMT TYPE IOPACTYASSGMT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IOPACTYASSGMT> TYPE IOPACTYASSGMT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IOPACTYASSGMT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IOPACTYASSGMT
  INTO TABLE IT_IOPACTYASSGMT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IOPACTYASSGMT
*  INTO TABLE @DATA(IT_IOPACTYASSGMT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IOPACTYASSGMT INDEX 1 INTO DATA(WA_IOPACTYASSGMT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IOPACTYASSGMT ASSIGNING <IOPACTYASSGMT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IOPACTYASSGMT>-MANDT = 1.
<IOPACTYASSGMT>-OPERATIONACTIVITY = 1.
<IOPACTYASSGMT>-OPERATIONACTYVERSIONCOUNTER = 1.
<IOPACTYASSGMT>-PRODNRSCETOOLBOOTYPE = 1.
<IOPACTYASSGMT>-PRODNRSCETOOLBOOGRP = 1.
ENDLOOP.

LOOP AT IT_IOPACTYASSGMT INTO WA_IOPACTYASSGMT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IOPACTYASSGMT-BOOOPERATIONPRTINTERNALID, sy-vline,
WA_IOPACTYASSGMT-MFGQUALIFNCERTIFICATE, sy-vline,
WA_IOPACTYASSGMT-MFGQUALIFNREQUIREDSKILLLEVEL, sy-vline,
WA_IOPACTYASSGMT-BOMITMBOOTYPE, sy-vline,
WA_IOPACTYASSGMT-BOMITMBOOGRP, sy-vline,
WA_IOPACTYASSGMT-BOOOPBOMITEMINTERNALID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IOPACTYASSGMT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IOPACTYASSGMT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IOPACTYASSGMT INTO WA_IOPACTYASSGMT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PRODNRSCETOOLBOOGRP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IOPACTYASSGMT-PRODNRSCETOOLBOOGRP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IOPACTYASSGMT-PRODNRSCETOOLBOOGRP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BOMITMBOOGRP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IOPACTYASSGMT-BOMITMBOOGRP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IOPACTYASSGMT-BOMITMBOOGRP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BILLOFMATERIALITEMUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IOPACTYASSGMT-BILLOFMATERIALITEMUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IOPACTYASSGMT-BILLOFMATERIALITEMUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BOOCHARCBOOGRP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IOPACTYASSGMT-BOOCHARCBOOGRP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IOPACTYASSGMT-BOOCHARCBOOGRP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IOPACTYASSGMT_STR,
MANDT TYPE STRING,
OPERATIONACTIVITY TYPE STRING,
OPERATIONACTYVERSIONCOUNTER TYPE STRING,
PRODNRSCETOOLBOOTYPE TYPE STRING,
PRODNRSCETOOLBOOGRP TYPE STRING,
BOOOPERATIONPRTINTERNALID TYPE STRING,
MFGQUALIFNCERTIFICATE TYPE STRING,
MFGQUALIFNREQUIREDSKILLLEVEL TYPE STRING,
BOMITMBOOTYPE TYPE STRING,
BOMITMBOOGRP TYPE STRING,
BOOOPBOMITEMINTERNALID TYPE STRING,
BILLOFMATERIALITEMQUANTITY TYPE STRING,
BILLOFMATERIALITEMUNIT TYPE STRING,
BOOCHARCBOOTYPE TYPE STRING,
BOOCHARCBOOGRP TYPE STRING,
BOOOPERATIONINTERNALID TYPE STRING,
BOOCHARACTERISTIC TYPE STRING,
OPACTYCHARACTERISTICITEM TYPE STRING,
WORKINSTRUCTION TYPE STRING,
WORKINSTRUCTIONVERSIONCOUNTER TYPE STRING,END OF T_EKKO_STR. DATA: WA_IOPACTYASSGMT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IOPACTYASSGMT_STR-MANDT sy-vline
WA_IOPACTYASSGMT_STR-OPERATIONACTIVITY sy-vline
WA_IOPACTYASSGMT_STR-OPERATIONACTYVERSIONCOUNTER sy-vline
WA_IOPACTYASSGMT_STR-PRODNRSCETOOLBOOTYPE sy-vline
WA_IOPACTYASSGMT_STR-PRODNRSCETOOLBOOGRP sy-vline
WA_IOPACTYASSGMT_STR-BOOOPERATIONPRTINTERNALID sy-vline
WA_IOPACTYASSGMT_STR-MFGQUALIFNCERTIFICATE sy-vline
WA_IOPACTYASSGMT_STR-MFGQUALIFNREQUIREDSKILLLEVEL sy-vline
WA_IOPACTYASSGMT_STR-BOMITMBOOTYPE sy-vline
WA_IOPACTYASSGMT_STR-BOMITMBOOGRP sy-vline
WA_IOPACTYASSGMT_STR-BOOOPBOMITEMINTERNALID sy-vline
WA_IOPACTYASSGMT_STR-BILLOFMATERIALITEMQUANTITY sy-vline
WA_IOPACTYASSGMT_STR-BILLOFMATERIALITEMUNIT sy-vline
WA_IOPACTYASSGMT_STR-BOOCHARCBOOTYPE sy-vline
WA_IOPACTYASSGMT_STR-BOOCHARCBOOGRP sy-vline
WA_IOPACTYASSGMT_STR-BOOOPERATIONINTERNALID sy-vline
WA_IOPACTYASSGMT_STR-BOOCHARACTERISTIC sy-vline
WA_IOPACTYASSGMT_STR-OPACTYCHARACTERISTICITEM sy-vline
WA_IOPACTYASSGMT_STR-WORKINSTRUCTION sy-vline
WA_IOPACTYASSGMT_STR-WORKINSTRUCTIONVERSIONCOUNTER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.