ABAP Select data from SAP table INV_PROCESS_CONTROL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP INV_PROCESS_CONTROL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to INV_PROCESS_CONTROL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the INV_PROCESS_CONTROL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_INV_PROCESS_CONTROL TYPE STANDARD TABLE OF INV_PROCESS_CONTROL,
      WA_INV_PROCESS_CONTROL TYPE INV_PROCESS_CONTROL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <INV_PROCESS_CONTROL> TYPE INV_PROCESS_CONTROL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_INV_PROCESS_CONTROL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM INV_PROCESS_CONTROL
  INTO TABLE IT_INV_PROCESS_CONTROL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM INV_PROCESS_CONTROL
*  INTO TABLE @DATA(IT_INV_PROCESS_CONTROL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_INV_PROCESS_CONTROL INDEX 1 INTO DATA(WA_INV_PROCESS_CONTROL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_INV_PROCESS_CONTROL ASSIGNING <INV_PROCESS_CONTROL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<INV_PROCESS_CONTROL>-PRCSUPP = 1.
<INV_PROCESS_CONTROL>-DOCPROC = 1.
<INV_PROCESS_CONTROL>-DOCREL = 1.
<INV_PROCESS_CONTROL>-CONTR = 1.
<INV_PROCESS_CONTROL>-FINAL = 1.
ENDLOOP.

LOOP AT IT_INV_PROCESS_CONTROL INTO WA_INV_PROCESS_CONTROL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_INV_PROCESS_CONTROL-NEXT_PROCESS, sy-vline,
WA_INV_PROCESS_CONTROL-ACTUAL_PROCESS, sy-vline,
WA_INV_PROCESS_CONTROL-ERROR_OCCURED, sy-vline,
WA_INV_PROCESS_CONTROL-DOC_DATA_CHANGED, sy-vline,
WA_INV_PROCESS_CONTROL-LOG_CHANGED, sy-vline,
WA_INV_PROCESS_CONTROL-FU_CONTROL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_INV_PROCESS_CONTROL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_INV_PROCESS_CONTROL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_INV_PROCESS_CONTROL INTO WA_INV_PROCESS_CONTROL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_INV_PROCESS_CONTROL_STR,
PRCSUPP TYPE STRING,
DOCPROC TYPE STRING,
DOCREL TYPE STRING,
CONTR TYPE STRING,
FINAL TYPE STRING,
NEXT_PROCESS TYPE STRING,
ACTUAL_PROCESS TYPE STRING,
ERROR_OCCURED TYPE STRING,
DOC_DATA_CHANGED TYPE STRING,
LOG_CHANGED TYPE STRING,
FU_CONTROL TYPE STRING,
X_DIALOG TYPE STRING,
STATUS_DATA TYPE STRING,
SEL_LINES TYPE STRING,
ADDLINES_ALLOWED TYPE STRING,
EVENT TYPE STRING,
CURRENT_DOCPROC TYPE STRING,
MANDT TYPE STRING,
INT_INV_DOC_NO TYPE STRING,
PROCESS_TYPE TYPE STRING,
PROCESS TYPE STRING,
STATUS TYPE STRING,
PROCESS_RUN_NO TYPE STRING,END OF T_EKKO_STR. DATA: WA_INV_PROCESS_CONTROL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_INV_PROCESS_CONTROL_STR-PRCSUPP sy-vline
WA_INV_PROCESS_CONTROL_STR-DOCPROC sy-vline
WA_INV_PROCESS_CONTROL_STR-DOCREL sy-vline
WA_INV_PROCESS_CONTROL_STR-CONTR sy-vline
WA_INV_PROCESS_CONTROL_STR-FINAL sy-vline
WA_INV_PROCESS_CONTROL_STR-NEXT_PROCESS sy-vline
WA_INV_PROCESS_CONTROL_STR-ACTUAL_PROCESS sy-vline
WA_INV_PROCESS_CONTROL_STR-ERROR_OCCURED sy-vline
WA_INV_PROCESS_CONTROL_STR-DOC_DATA_CHANGED sy-vline
WA_INV_PROCESS_CONTROL_STR-LOG_CHANGED sy-vline
WA_INV_PROCESS_CONTROL_STR-FU_CONTROL sy-vline
WA_INV_PROCESS_CONTROL_STR-X_DIALOG sy-vline
WA_INV_PROCESS_CONTROL_STR-STATUS_DATA sy-vline
WA_INV_PROCESS_CONTROL_STR-SEL_LINES sy-vline
WA_INV_PROCESS_CONTROL_STR-ADDLINES_ALLOWED sy-vline
WA_INV_PROCESS_CONTROL_STR-EVENT sy-vline
WA_INV_PROCESS_CONTROL_STR-CURRENT_DOCPROC sy-vline
WA_INV_PROCESS_CONTROL_STR-MANDT sy-vline
WA_INV_PROCESS_CONTROL_STR-INT_INV_DOC_NO sy-vline
WA_INV_PROCESS_CONTROL_STR-PROCESS_TYPE sy-vline
WA_INV_PROCESS_CONTROL_STR-PROCESS sy-vline
WA_INV_PROCESS_CONTROL_STR-STATUS sy-vline
WA_INV_PROCESS_CONTROL_STR-PROCESS_RUN_NO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.