ABAP Select data from SAP table INTFTASKTECTP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP INTFTASKTECTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to INTFTASKTECTP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the INTFTASKTECTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_INTFTASKTECTP TYPE STANDARD TABLE OF INTFTASKTECTP,
      WA_INTFTASKTECTP TYPE INTFTASKTECTP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <INTFTASKTECTP> TYPE INTFTASKTECTP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_INTFTASKTECTP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM INTFTASKTECTP
  INTO TABLE IT_INTFTASKTECTP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM INTFTASKTECTP
*  INTO TABLE @DATA(IT_INTFTASKTECTP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_INTFTASKTECTP INDEX 1 INTO DATA(WA_INTFTASKTECTP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_INTFTASKTECTP ASSIGNING <INTFTASKTECTP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<INTFTASKTECTP>-MANDT = 1.
<INTFTASKTECTP>-MAINTENANCENOTIFICATIONTASK = 1.
<INTFTASKTECTP>-MAINTENANCENOTIFICATION = 1.
<INTFTASKTECTP>-MAINTNOTIFICATIONTASKFOREDIT = 1.
<INTFTASKTECTP>-MAINTENANCENOTIFICATIONITEM = 1.
ENDLOOP.

LOOP AT IT_INTFTASKTECTP INTO WA_INTFTASKTECTP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_INTFTASKTECTP-MAINTENANCENOTIFICATIONCAUSE, sy-vline,
WA_INTFTASKTECTP-MAINTNOTIFTASKTXT, sy-vline,
WA_INTFTASKTECTP-MAINTNOTIFTASKCODECATALOG, sy-vline,
WA_INTFTASKTECTP-MAINTNOTIFTASKCODEGROUP, sy-vline,
WA_INTFTASKTECTP-MAINTNOTIFTASKCODE, sy-vline,
WA_INTFTASKTECTP-PLANNEDSTARTDATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_INTFTASKTECTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_INTFTASKTECTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_INTFTASKTECTP INTO WA_INTFTASKTECTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field MAINTENANCENOTIFICATION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_INTFTASKTECTP-MAINTENANCENOTIFICATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INTFTASKTECTP-MAINTENANCENOTIFICATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PARVW, internal->external for field RESPONSIBLEPERSONFUNCTIONCODE CALL FUNCTION 'CONVERSION_EXIT_PARVW_OUTPUT' EXPORTING input = WA_INTFTASKTECTP-RESPONSIBLEPERSONFUNCTIONCODE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INTFTASKTECTP-RESPONSIBLEPERSONFUNCTIONCODE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RESPONSIBLEPERSON CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_INTFTASKTECTP-RESPONSIBLEPERSON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INTFTASKTECTP-RESPONSIBLEPERSON.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_INTFTASKTECTP_STR,
MANDT TYPE STRING,
MAINTENANCENOTIFICATIONTASK TYPE STRING,
MAINTENANCENOTIFICATION TYPE STRING,
MAINTNOTIFICATIONTASKFOREDIT TYPE STRING,
MAINTENANCENOTIFICATIONITEM TYPE STRING,
MAINTENANCENOTIFICATIONCAUSE TYPE STRING,
MAINTNOTIFTASKTXT TYPE STRING,
MAINTNOTIFTASKCODECATALOG TYPE STRING,
MAINTNOTIFTASKCODEGROUP TYPE STRING,
MAINTNOTIFTASKCODE TYPE STRING,
PLANNEDSTARTDATE TYPE STRING,
PLANNEDSTARTTIME TYPE STRING,
PLANNEDENDDATE TYPE STRING,
PLANNEDENDTIME TYPE STRING,
COMPLETEDBYUSER TYPE STRING,
COMPLETIONDATE TYPE STRING,
COMPLETIONTIME TYPE STRING,
RESPONSIBLEPERSONFUNCTIONCODE TYPE STRING,
RESPONSIBLEPERSON TYPE STRING,
MAINTNOTIFTASKINTERNALID TYPE STRING,
ISDELETED TYPE STRING,END OF T_EKKO_STR. DATA: WA_INTFTASKTECTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_INTFTASKTECTP_STR-MANDT sy-vline
WA_INTFTASKTECTP_STR-MAINTENANCENOTIFICATIONTASK sy-vline
WA_INTFTASKTECTP_STR-MAINTENANCENOTIFICATION sy-vline
WA_INTFTASKTECTP_STR-MAINTNOTIFICATIONTASKFOREDIT sy-vline
WA_INTFTASKTECTP_STR-MAINTENANCENOTIFICATIONITEM sy-vline
WA_INTFTASKTECTP_STR-MAINTENANCENOTIFICATIONCAUSE sy-vline
WA_INTFTASKTECTP_STR-MAINTNOTIFTASKTXT sy-vline
WA_INTFTASKTECTP_STR-MAINTNOTIFTASKCODECATALOG sy-vline
WA_INTFTASKTECTP_STR-MAINTNOTIFTASKCODEGROUP sy-vline
WA_INTFTASKTECTP_STR-MAINTNOTIFTASKCODE sy-vline
WA_INTFTASKTECTP_STR-PLANNEDSTARTDATE sy-vline
WA_INTFTASKTECTP_STR-PLANNEDSTARTTIME sy-vline
WA_INTFTASKTECTP_STR-PLANNEDENDDATE sy-vline
WA_INTFTASKTECTP_STR-PLANNEDENDTIME sy-vline
WA_INTFTASKTECTP_STR-COMPLETEDBYUSER sy-vline
WA_INTFTASKTECTP_STR-COMPLETIONDATE sy-vline
WA_INTFTASKTECTP_STR-COMPLETIONTIME sy-vline
WA_INTFTASKTECTP_STR-RESPONSIBLEPERSONFUNCTIONCODE sy-vline
WA_INTFTASKTECTP_STR-RESPONSIBLEPERSON sy-vline
WA_INTFTASKTECTP_STR-MAINTNOTIFTASKINTERNALID sy-vline
WA_INTFTASKTECTP_STR-ISDELETED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.