ABAP Select data from SAP table INOTIFACTYDATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP INOTIFACTYDATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to INOTIFACTYDATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the INOTIFACTYDATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_INOTIFACTYDATA TYPE STANDARD TABLE OF INOTIFACTYDATA,
      WA_INOTIFACTYDATA TYPE INOTIFACTYDATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <INOTIFACTYDATA> TYPE INOTIFACTYDATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_INOTIFACTYDATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM INOTIFACTYDATA
  INTO TABLE IT_INOTIFACTYDATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM INOTIFACTYDATA
*  INTO TABLE @DATA(IT_INOTIFACTYDATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_INOTIFACTYDATA INDEX 1 INTO DATA(WA_INOTIFACTYDATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_INOTIFACTYDATA ASSIGNING <INOTIFACTYDATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<INOTIFACTYDATA>-MANDT = 1.
<INOTIFACTYDATA>-MAINTNOTIFICATIONACTIVITY = 1.
<INOTIFACTYDATA>-MAINTENANCENOTIFICATION = 1.
<INOTIFACTYDATA>-MAINTENANCENOTIFICATIONITEM = 1.
<INOTIFACTYDATA>-MAINTNOTIFACTYTXT = 1.
ENDLOOP.

LOOP AT IT_INOTIFACTYDATA INTO WA_INOTIFACTYDATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_INOTIFACTYDATA-MAINTNOTIFICATIONACTIVITYCODE, sy-vline,
WA_INOTIFACTYDATA-MAINTNOTIFACTIVITYCODEGROUP, sy-vline,
WA_INOTIFACTYDATA-MAINTNOTIFACTIVITYCODECATALOG, sy-vline,
WA_INOTIFACTYDATA-ISDELETED, sy-vline,
WA_INOTIFACTYDATA-LASTCHANGEDATETIME, sy-vline,
WA_INOTIFACTYDATA-ASSEMBLYHEADER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_INOTIFACTYDATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_INOTIFACTYDATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_INOTIFACTYDATA INTO WA_INOTIFACTYDATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field MAINTENANCENOTIFICATION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_INOTIFACTYDATA-MAINTENANCENOTIFICATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INOTIFACTYDATA-MAINTENANCENOTIFICATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field ASSEMBLYHEADER CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_INOTIFACTYDATA-ASSEMBLYHEADER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INOTIFACTYDATA-ASSEMBLYHEADER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUIPMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_INOTIFACTYDATA-EQUIPMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INOTIFACTYDATA-EQUIPMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field FUNCTIONALLOCATION CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_INOTIFACTYDATA-FUNCTIONALLOCATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INOTIFACTYDATA-FUNCTIONALLOCATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COSTCENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_INOTIFACTYDATA-COSTCENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INOTIFACTYDATA-COSTCENTER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field ASSEMBLY CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_INOTIFACTYDATA-ASSEMBLY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INOTIFACTYDATA-ASSEMBLY.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_INOTIFACTYDATA_STR,
MANDT TYPE STRING,
MAINTNOTIFICATIONACTIVITY TYPE STRING,
MAINTENANCENOTIFICATION TYPE STRING,
MAINTENANCENOTIFICATIONITEM TYPE STRING,
MAINTNOTIFACTYTXT TYPE STRING,
MAINTNOTIFICATIONACTIVITYCODE TYPE STRING,
MAINTNOTIFACTIVITYCODEGROUP TYPE STRING,
MAINTNOTIFACTIVITYCODECATALOG TYPE STRING,
ISDELETED TYPE STRING,
LASTCHANGEDATETIME TYPE STRING,
ASSEMBLYHEADER TYPE STRING,
EQUIPMENT TYPE STRING,
FUNCTIONALLOCATION TYPE STRING,
MAINTENANCEPLANNINGPLANT TYPE STRING,
MAINTENANCEPLANNERGROUP TYPE STRING,
MAINTENANCEPLANT TYPE STRING,
CONTROLLINGAREA TYPE STRING,
COSTCENTER TYPE STRING,
NOTIFICATIONORIGIN TYPE STRING,
NOTIFICATIONTYPE TYPE STRING,
NOTIFICATIONCREATIONDATE TYPE STRING,
ASSEMBLY TYPE STRING,
MAINTNOTIFDAMAGECODECATALOG TYPE STRING,
MAINTNOTIFICATIONDAMAGECODE TYPE STRING,
MAINTNOTIFDAMAGECODEGROUP TYPE STRING,
DEFECTCLASS TYPE STRING,
MAINTNOTIFOBJPRTCODE TYPE STRING,
MAINTNOTIFOBJPRTCODEGROUP TYPE STRING,
MAINTNOTIFOBJPRTCODECATALOG TYPE STRING,
NUMBEROFMAINTNOTIFACTIVITIES TYPE STRING,END OF T_EKKO_STR. DATA: WA_INOTIFACTYDATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_INOTIFACTYDATA_STR-MANDT sy-vline
WA_INOTIFACTYDATA_STR-MAINTNOTIFICATIONACTIVITY sy-vline
WA_INOTIFACTYDATA_STR-MAINTENANCENOTIFICATION sy-vline
WA_INOTIFACTYDATA_STR-MAINTENANCENOTIFICATIONITEM sy-vline
WA_INOTIFACTYDATA_STR-MAINTNOTIFACTYTXT sy-vline
WA_INOTIFACTYDATA_STR-MAINTNOTIFICATIONACTIVITYCODE sy-vline
WA_INOTIFACTYDATA_STR-MAINTNOTIFACTIVITYCODEGROUP sy-vline
WA_INOTIFACTYDATA_STR-MAINTNOTIFACTIVITYCODECATALOG sy-vline
WA_INOTIFACTYDATA_STR-ISDELETED sy-vline
WA_INOTIFACTYDATA_STR-LASTCHANGEDATETIME sy-vline
WA_INOTIFACTYDATA_STR-ASSEMBLYHEADER sy-vline
WA_INOTIFACTYDATA_STR-EQUIPMENT sy-vline
WA_INOTIFACTYDATA_STR-FUNCTIONALLOCATION sy-vline
WA_INOTIFACTYDATA_STR-MAINTENANCEPLANNINGPLANT sy-vline
WA_INOTIFACTYDATA_STR-MAINTENANCEPLANNERGROUP sy-vline
WA_INOTIFACTYDATA_STR-MAINTENANCEPLANT sy-vline
WA_INOTIFACTYDATA_STR-CONTROLLINGAREA sy-vline
WA_INOTIFACTYDATA_STR-COSTCENTER sy-vline
WA_INOTIFACTYDATA_STR-NOTIFICATIONORIGIN sy-vline
WA_INOTIFACTYDATA_STR-NOTIFICATIONTYPE sy-vline
WA_INOTIFACTYDATA_STR-NOTIFICATIONCREATIONDATE sy-vline
WA_INOTIFACTYDATA_STR-ASSEMBLY sy-vline
WA_INOTIFACTYDATA_STR-MAINTNOTIFDAMAGECODECATALOG sy-vline
WA_INOTIFACTYDATA_STR-MAINTNOTIFICATIONDAMAGECODE sy-vline
WA_INOTIFACTYDATA_STR-MAINTNOTIFDAMAGECODEGROUP sy-vline
WA_INOTIFACTYDATA_STR-DEFECTCLASS sy-vline
WA_INOTIFACTYDATA_STR-MAINTNOTIFOBJPRTCODE sy-vline
WA_INOTIFACTYDATA_STR-MAINTNOTIFOBJPRTCODEGROUP sy-vline
WA_INOTIFACTYDATA_STR-MAINTNOTIFOBJPRTCODECATALOG sy-vline
WA_INOTIFACTYDATA_STR-NUMBEROFMAINTNOTIFACTIVITIES sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.