ABAP Select data from SAP table INFO_BMEPT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP INFO_BMEPT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to INFO_BMEPT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the INFO_BMEPT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_INFO_BMEPT TYPE STANDARD TABLE OF INFO_BMEPT,
      WA_INFO_BMEPT TYPE INFO_BMEPT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <INFO_BMEPT> TYPE INFO_BMEPT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_INFO_BMEPT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM INFO_BMEPT
  INTO TABLE IT_INFO_BMEPT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM INFO_BMEPT
*  INTO TABLE @DATA(IT_INFO_BMEPT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_INFO_BMEPT INDEX 1 INTO DATA(WA_INFO_BMEPT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_INFO_BMEPT ASSIGNING <INFO_BMEPT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<INFO_BMEPT>-LANGU = 1.
<INFO_BMEPT>-NAME = 1.
<INFO_BMEPT>-DEVCLASS = 1.
<INFO_BMEPT>-FCT_ID = 1.
<INFO_BMEPT>-AS4LOCAL = 1.
ENDLOOP.

LOOP AT IT_INFO_BMEPT INTO WA_INFO_BMEPT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_INFO_BMEPT-FSTUSER, sy-vline,
WA_INFO_BMEPT-FSTDATE, sy-vline,
WA_INFO_BMEPT-FSTTIME, sy-vline,
WA_INFO_BMEPT-LSTUSER, sy-vline,
WA_INFO_BMEPT-LSTDATE, sy-vline,
WA_INFO_BMEPT-LSTTIME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_INFO_BMEPT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_INFO_BMEPT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_INFO_BMEPT INTO WA_INFO_BMEPT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_INFO_BMEPT-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INFO_BMEPT-LANGU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit RELE, internal->external for field RELE CALL FUNCTION 'CONVERSION_EXIT_RELE_OUTPUT' EXPORTING input = WA_INFO_BMEPT-RELE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INFO_BMEPT-RELE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit RELE, internal->external for field LSTRELE CALL FUNCTION 'CONVERSION_EXIT_RELE_OUTPUT' EXPORTING input = WA_INFO_BMEPT-LSTRELE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INFO_BMEPT-LSTRELE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FTYPE, internal->external for field MAIN_PRO CALL FUNCTION 'CONVERSION_EXIT_FTYPE_OUTPUT' EXPORTING input = WA_INFO_BMEPT-MAIN_PRO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INFO_BMEPT-MAIN_PRO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit RELE, internal->external for field API_VER CALL FUNCTION 'CONVERSION_EXIT_RELE_OUTPUT' EXPORTING input = WA_INFO_BMEPT-API_VER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INFO_BMEPT-API_VER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_INFO_BMEPT_STR,
LANGU TYPE STRING,
NAME TYPE STRING,
DEVCLASS TYPE STRING,
FCT_ID TYPE STRING,
AS4LOCAL TYPE STRING,
FSTUSER TYPE STRING,
FSTDATE TYPE STRING,
FSTTIME TYPE STRING,
LSTUSER TYPE STRING,
LSTDATE TYPE STRING,
LSTTIME TYPE STRING,
REF_FCT TYPE STRING,
ONLZ TYPE STRING,
ONLD TYPE STRING,
BATZ TYPE STRING,
BATD TYPE STRING,
AUTZ TYPE STRING,
AUTD TYPE STRING,
MANU TYPE STRING,
OPTN TYPE STRING,
REVISION TYPE STRING,
STANDARD TYPE STRING,
CLAS TYPE STRING,
RELE TYPE STRING,
TR_OBJ_TYP TYPE STRING,
TR_OBJ_ID TYPE STRING,
SWO_OBJTYP TYPE STRING,
SWO_METHOD TYPE STRING,
APPL TYPE STRING,
ALE_AGGR TYPE STRING,
LSTRELE TYPE STRING,
ARIID TYPE STRING,
MAIN_PRO TYPE STRING,
SMODNAME TYPE STRING,
CUSTASS TYPE STRING,
API_VER TYPE STRING,
STATUS TYPE STRING,
SYNCH TYPE STRING,
TSTAMP TYPE STRING,
MODEL_ONLY TYPE STRING,
STRUCT_ID TYPE STRING,
DLVUNIT TYPE STRING,END OF T_EKKO_STR. DATA: WA_INFO_BMEPT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_INFO_BMEPT_STR-LANGU sy-vline
WA_INFO_BMEPT_STR-NAME sy-vline
WA_INFO_BMEPT_STR-DEVCLASS sy-vline
WA_INFO_BMEPT_STR-FCT_ID sy-vline
WA_INFO_BMEPT_STR-AS4LOCAL sy-vline
WA_INFO_BMEPT_STR-FSTUSER sy-vline
WA_INFO_BMEPT_STR-FSTDATE sy-vline
WA_INFO_BMEPT_STR-FSTTIME sy-vline
WA_INFO_BMEPT_STR-LSTUSER sy-vline
WA_INFO_BMEPT_STR-LSTDATE sy-vline
WA_INFO_BMEPT_STR-LSTTIME sy-vline
WA_INFO_BMEPT_STR-REF_FCT sy-vline
WA_INFO_BMEPT_STR-ONLZ sy-vline
WA_INFO_BMEPT_STR-ONLD sy-vline
WA_INFO_BMEPT_STR-BATZ sy-vline
WA_INFO_BMEPT_STR-BATD sy-vline
WA_INFO_BMEPT_STR-AUTZ sy-vline
WA_INFO_BMEPT_STR-AUTD sy-vline
WA_INFO_BMEPT_STR-MANU sy-vline
WA_INFO_BMEPT_STR-OPTN sy-vline
WA_INFO_BMEPT_STR-REVISION sy-vline
WA_INFO_BMEPT_STR-STANDARD sy-vline
WA_INFO_BMEPT_STR-CLAS sy-vline
WA_INFO_BMEPT_STR-RELE sy-vline
WA_INFO_BMEPT_STR-TR_OBJ_TYP sy-vline
WA_INFO_BMEPT_STR-TR_OBJ_ID sy-vline
WA_INFO_BMEPT_STR-SWO_OBJTYP sy-vline
WA_INFO_BMEPT_STR-SWO_METHOD sy-vline
WA_INFO_BMEPT_STR-APPL sy-vline
WA_INFO_BMEPT_STR-ALE_AGGR sy-vline
WA_INFO_BMEPT_STR-LSTRELE sy-vline
WA_INFO_BMEPT_STR-ARIID sy-vline
WA_INFO_BMEPT_STR-MAIN_PRO sy-vline
WA_INFO_BMEPT_STR-SMODNAME sy-vline
WA_INFO_BMEPT_STR-CUSTASS sy-vline
WA_INFO_BMEPT_STR-API_VER sy-vline
WA_INFO_BMEPT_STR-STATUS sy-vline
WA_INFO_BMEPT_STR-SYNCH sy-vline
WA_INFO_BMEPT_STR-TSTAMP sy-vline
WA_INFO_BMEPT_STR-MODEL_ONLY sy-vline
WA_INFO_BMEPT_STR-STRUCT_ID sy-vline
WA_INFO_BMEPT_STR-DLVUNIT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.