ABAP Select data from SAP table INET into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP INET table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to INET. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the INET table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_INET TYPE STANDARD TABLE OF INET,
      WA_INET TYPE INET,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <INET> TYPE INET.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_INET.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM INET
  INTO TABLE IT_INET.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM INET
*  INTO TABLE @DATA(IT_INET2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_INET INDEX 1 INTO DATA(WA_INET2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_INET ASSIGNING <INET>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<INET>-MANDT = 1.
<INET>-KANTE = 1.
<INET>-MLANG = 1.
<INET>-NETID = 1.
<INET>-KANTYP = 1.
ENDLOOP.

LOOP AT IT_INET INTO WA_INET.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_INET-TPVON, sy-vline,
WA_INET-EQVON, sy-vline,
WA_INET-TPNACH, sy-vline,
WA_INET-EQNACH, sy-vline,
WA_INET-LFDKNR, sy-vline,
WA_INET-DATVA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_INET you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_INET TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_INET INTO WA_INET. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KANTE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_INET-KANTE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INET-KANTE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field MLANG CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_INET-MLANG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INET-MLANG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPVON CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_INET-TPVON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INET-TPVON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQVON CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_INET-EQVON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INET-EQVON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPNACH CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_INET-TPNACH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INET-TPNACH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQNACH CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_INET-EQNACH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INET-EQNACH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPKANT CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_INET-TPKANT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INET-TPKANT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQKANT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_INET-EQKANT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INET-EQKANT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_INET-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_INET-MATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_INET_STR,
MANDT TYPE STRING,
KANTE TYPE STRING,
MLANG TYPE STRING,
NETID TYPE STRING,
KANTYP TYPE STRING,
TPVON TYPE STRING,
EQVON TYPE STRING,
TPNACH TYPE STRING,
EQNACH TYPE STRING,
LFDKNR TYPE STRING,
DATVA TYPE STRING,
ZEITVA TYPE STRING,
DATVB TYPE STRING,
ZEITVB TYPE STRING,
STATUS TYPE STRING,
TPKANT TYPE STRING,
EQKANT TYPE STRING,
MEDIU TYPE STRING,
BEZARP TYPE STRING,
BEZARL TYPE STRING,
ERDAT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
BEGRU TYPE STRING,
LVORM TYPE STRING,
NETYP TYPE STRING,
MATNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_INET_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_INET_STR-MANDT sy-vline
WA_INET_STR-KANTE sy-vline
WA_INET_STR-MLANG sy-vline
WA_INET_STR-NETID sy-vline
WA_INET_STR-KANTYP sy-vline
WA_INET_STR-TPVON sy-vline
WA_INET_STR-EQVON sy-vline
WA_INET_STR-TPNACH sy-vline
WA_INET_STR-EQNACH sy-vline
WA_INET_STR-LFDKNR sy-vline
WA_INET_STR-DATVA sy-vline
WA_INET_STR-ZEITVA sy-vline
WA_INET_STR-DATVB sy-vline
WA_INET_STR-ZEITVB sy-vline
WA_INET_STR-STATUS sy-vline
WA_INET_STR-TPKANT sy-vline
WA_INET_STR-EQKANT sy-vline
WA_INET_STR-MEDIU sy-vline
WA_INET_STR-BEZARP sy-vline
WA_INET_STR-BEZARL sy-vline
WA_INET_STR-ERDAT sy-vline
WA_INET_STR-ERNAM sy-vline
WA_INET_STR-AEDAT sy-vline
WA_INET_STR-AENAM sy-vline
WA_INET_STR-BEGRU sy-vline
WA_INET_STR-LVORM sy-vline
WA_INET_STR-NETYP sy-vline
WA_INET_STR-MATNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.