ABAP Select data from SAP table IMP_TEST_INTERVALL_QUEUE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IMP_TEST_INTERVALL_QUEUE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IMP_TEST_INTERVALL_QUEUE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IMP_TEST_INTERVALL_QUEUE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IMP_TEST_INTERVALL_QUEUE TYPE STANDARD TABLE OF IMP_TEST_INTERVALL_QUEUE,
      WA_IMP_TEST_INTERVALL_QUEUE TYPE IMP_TEST_INTERVALL_QUEUE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IMP_TEST_INTERVALL_QUEUE> TYPE IMP_TEST_INTERVALL_QUEUE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IMP_TEST_INTERVALL_QUEUE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IMP_TEST_INTERVALL_QUEUE
  INTO TABLE IT_IMP_TEST_INTERVALL_QUEUE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IMP_TEST_INTERVALL_QUEUE
*  INTO TABLE @DATA(IT_IMP_TEST_INTERVALL_QUEUE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IMP_TEST_INTERVALL_QUEUE INDEX 1 INTO DATA(WA_IMP_TEST_INTERVALL_QUEUE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IMP_TEST_INTERVALL_QUEUE ASSIGNING <IMP_TEST_INTERVALL_QUEUE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IMP_TEST_INTERVALL_QUEUE>-RELEASE = 1.
<IMP_TEST_INTERVALL_QUEUE>-PAKID = 1.
<IMP_TEST_INTERVALL_QUEUE>-ALEID = 1.
<IMP_TEST_INTERVALL_QUEUE>-ALETXT = 1.
<IMP_TEST_INTERVALL_QUEUE>-TYPID = 1.
ENDLOOP.

LOOP AT IT_IMP_TEST_INTERVALL_QUEUE INTO WA_IMP_TEST_INTERVALL_QUEUE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IMP_TEST_INTERVALL_QUEUE-ALSID, sy-vline,
WA_IMP_TEST_INTERVALL_QUEUE-INTERVALL, sy-vline,
WA_IMP_TEST_INTERVALL_QUEUE-TRACK, sy-vline,
WA_IMP_TEST_INTERVALL_QUEUE-PAKID, sy-vline,
WA_IMP_TEST_INTERVALL_QUEUE-TYPID, sy-vline,
WA_IMP_TEST_INTERVALL_QUEUE-ALSID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IMP_TEST_INTERVALL_QUEUE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IMP_TEST_INTERVALL_QUEUE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IMP_TEST_INTERVALL_QUEUE INTO WA_IMP_TEST_INTERVALL_QUEUE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IMP_TEST_INTERVALL_QUEUE_STR,
RELEASE TYPE STRING,
PAKID TYPE STRING,
ALEID TYPE STRING,
ALETXT TYPE STRING,
TYPID TYPE STRING,
ALSID TYPE STRING,
INTERVALL TYPE STRING,
TRACK TYPE STRING,
PAKID TYPE STRING,
TYPID TYPE STRING,
ALSID TYPE STRING,
LO TYPE STRING,
PAKID TYPE STRING,
ALEID TYPE STRING,
HI TYPE STRING,
PAKID TYPE STRING,
ALEID TYPE STRING,
MESSAGES TYPE STRING,
QUEUE TYPE STRING,
OBJ_VERSNOS TYPE STRING,
EXPAND TYPE STRING,
STATUS_INT TYPE STRING,
STATUS_CINSTS TYPE STRING,
IMPL_SYSTEM TYPE STRING,
IMPL_SYSTEM_TYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_IMP_TEST_INTERVALL_QUEUE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-RELEASE sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-PAKID sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-ALEID sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-ALETXT sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-TYPID sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-ALSID sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-INTERVALL sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-TRACK sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-PAKID sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-TYPID sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-ALSID sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-LO sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-PAKID sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-ALEID sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-HI sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-PAKID sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-ALEID sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-MESSAGES sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-QUEUE sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-OBJ_VERSNOS sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-EXPAND sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-STATUS_INT sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-STATUS_CINSTS sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-IMPL_SYSTEM sy-vline
WA_IMP_TEST_INTERVALL_QUEUE_STR-IMPL_SYSTEM_TYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.