ABAP Select data from SAP table IJITOUTBCALLCUBE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IJITOUTBCALLCUBE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IJITOUTBCALLCUBE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IJITOUTBCALLCUBE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IJITOUTBCALLCUBE TYPE STANDARD TABLE OF IJITOUTBCALLCUBE,
      WA_IJITOUTBCALLCUBE TYPE IJITOUTBCALLCUBE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IJITOUTBCALLCUBE> TYPE IJITOUTBCALLCUBE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IJITOUTBCALLCUBE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IJITOUTBCALLCUBE
  INTO TABLE IT_IJITOUTBCALLCUBE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IJITOUTBCALLCUBE
*  INTO TABLE @DATA(IT_IJITOUTBCALLCUBE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IJITOUTBCALLCUBE INDEX 1 INTO DATA(WA_IJITOUTBCALLCUBE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IJITOUTBCALLCUBE ASSIGNING <IJITOUTBCALLCUBE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IJITOUTBCALLCUBE>-MANDT = 1.
<IJITOUTBCALLCUBE>-INTERNALJITCALLNUMBER = 1.
<IJITOUTBCALLCUBE>-COMPGRPNUMBER = 1.
<IJITOUTBCALLCUBE>-JITCALLITEMNUMBER = 1.
<IJITOUTBCALLCUBE>-JITLIFECYCLESTATUS = 1.
ENDLOOP.

LOOP AT IT_IJITOUTBCALLCUBE INTO WA_IJITOUTBCALLCUBE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IJITOUTBCALLCUBE-JITLIFECYCLESTATUSTEXT, sy-vline,
WA_IJITOUTBCALLCUBE-JITCALLTYPE, sy-vline,
WA_IJITOUTBCALLCUBE-PLANT, sy-vline,
WA_IJITOUTBCALLCUBE-STORAGELOCATION, sy-vline,
WA_IJITOUTBCALLCUBE-REQUIREMENTDATETIME, sy-vline,
WA_IJITOUTBCALLCUBE-JITINTERNALSTATUSTEXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IJITOUTBCALLCUBE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IJITOUTBCALLCUBE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IJITOUTBCALLCUBE INTO WA_IJITOUTBCALLCUBE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INTERNALJITCALLNUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IJITOUTBCALLCUBE-INTERNALJITCALLNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IJITOUTBCALLCUBE-INTERNALJITCALLNUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field JITCONTROLCYCLE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IJITOUTBCALLCUBE-JITCONTROLCYCLE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IJITOUTBCALLCUBE-JITCONTROLCYCLE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUANTITYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IJITOUTBCALLCUBE-QUANTITYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IJITOUTBCALLCUBE-QUANTITYUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IJITOUTBCALLCUBE-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IJITOUTBCALLCUBE-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLANNEDORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IJITOUTBCALLCUBE-PLANNEDORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IJITOUTBCALLCUBE-PLANNEDORDER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUPPLIER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IJITOUTBCALLCUBE-SUPPLIER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IJITOUTBCALLCUBE-SUPPLIER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IJITOUTBCALLCUBE_STR,
MANDT TYPE STRING,
INTERNALJITCALLNUMBER TYPE STRING,
COMPGRPNUMBER TYPE STRING,
JITCALLITEMNUMBER TYPE STRING,
JITLIFECYCLESTATUS TYPE STRING,
JITLIFECYCLESTATUSTEXT TYPE STRING,
JITCALLTYPE TYPE STRING,
PLANT TYPE STRING,
STORAGELOCATION TYPE STRING,
REQUIREMENTDATETIME TYPE STRING,
JITINTERNALSTATUSTEXT TYPE STRING,
JITINTPROCESSINGSTATUS TYPE STRING,
PRODUCTIONSUPPLYAREA TYPE STRING,
JITCONTROLCYCLE TYPE STRING,
RESPONSIBLE TYPE STRING,
JITSTOCKTRANSFERSTSTEXT TYPE STRING,
JITOUTBSTOCKTRANSFERSTS TYPE STRING,
JITOUTBDESTINATIONSTORLOC TYPE STRING,
REQUESTEDQUANTITY TYPE STRING,
ACTUALDELIVEREDQUANTITY TYPE STRING,
QUANTITYUNIT TYPE STRING,
JITOUTBTRANSFERREDQUANTITY TYPE STRING,
JITOUTBMINIMUMQUANTITY TYPE STRING,
JITOUTBPICKEDQUANTITY TYPE STRING,
MATERIAL TYPE STRING,
STORAGEBIN TYPE STRING,
PLANNEDORDER TYPE STRING,
PRODUCTNAME TYPE STRING,
TOTALNUMBEROFJITCALLS TYPE STRING,
NUMBEROFDISTINCTPRODUCTS TYPE STRING,
JITOUTBDEVIATIONINQTY TYPE STRING,
JITEXTERNALREPLENISHMENT TYPE STRING,
SUPPLIER TYPE STRING,
UNITOFMEASURENUMBEROFDECIMALS TYPE STRING,END OF T_EKKO_STR. DATA: WA_IJITOUTBCALLCUBE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IJITOUTBCALLCUBE_STR-MANDT sy-vline
WA_IJITOUTBCALLCUBE_STR-INTERNALJITCALLNUMBER sy-vline
WA_IJITOUTBCALLCUBE_STR-COMPGRPNUMBER sy-vline
WA_IJITOUTBCALLCUBE_STR-JITCALLITEMNUMBER sy-vline
WA_IJITOUTBCALLCUBE_STR-JITLIFECYCLESTATUS sy-vline
WA_IJITOUTBCALLCUBE_STR-JITLIFECYCLESTATUSTEXT sy-vline
WA_IJITOUTBCALLCUBE_STR-JITCALLTYPE sy-vline
WA_IJITOUTBCALLCUBE_STR-PLANT sy-vline
WA_IJITOUTBCALLCUBE_STR-STORAGELOCATION sy-vline
WA_IJITOUTBCALLCUBE_STR-REQUIREMENTDATETIME sy-vline
WA_IJITOUTBCALLCUBE_STR-JITINTERNALSTATUSTEXT sy-vline
WA_IJITOUTBCALLCUBE_STR-JITINTPROCESSINGSTATUS sy-vline
WA_IJITOUTBCALLCUBE_STR-PRODUCTIONSUPPLYAREA sy-vline
WA_IJITOUTBCALLCUBE_STR-JITCONTROLCYCLE sy-vline
WA_IJITOUTBCALLCUBE_STR-RESPONSIBLE sy-vline
WA_IJITOUTBCALLCUBE_STR-JITSTOCKTRANSFERSTSTEXT sy-vline
WA_IJITOUTBCALLCUBE_STR-JITOUTBSTOCKTRANSFERSTS sy-vline
WA_IJITOUTBCALLCUBE_STR-JITOUTBDESTINATIONSTORLOC sy-vline
WA_IJITOUTBCALLCUBE_STR-REQUESTEDQUANTITY sy-vline
WA_IJITOUTBCALLCUBE_STR-ACTUALDELIVEREDQUANTITY sy-vline
WA_IJITOUTBCALLCUBE_STR-QUANTITYUNIT sy-vline
WA_IJITOUTBCALLCUBE_STR-JITOUTBTRANSFERREDQUANTITY sy-vline
WA_IJITOUTBCALLCUBE_STR-JITOUTBMINIMUMQUANTITY sy-vline
WA_IJITOUTBCALLCUBE_STR-JITOUTBPICKEDQUANTITY sy-vline
WA_IJITOUTBCALLCUBE_STR-MATERIAL sy-vline
WA_IJITOUTBCALLCUBE_STR-STORAGEBIN sy-vline
WA_IJITOUTBCALLCUBE_STR-PLANNEDORDER sy-vline
WA_IJITOUTBCALLCUBE_STR-PRODUCTNAME sy-vline
WA_IJITOUTBCALLCUBE_STR-TOTALNUMBEROFJITCALLS sy-vline
WA_IJITOUTBCALLCUBE_STR-NUMBEROFDISTINCTPRODUCTS sy-vline
WA_IJITOUTBCALLCUBE_STR-JITOUTBDEVIATIONINQTY sy-vline
WA_IJITOUTBCALLCUBE_STR-JITEXTERNALREPLENISHMENT sy-vline
WA_IJITOUTBCALLCUBE_STR-SUPPLIER sy-vline
WA_IJITOUTBCALLCUBE_STR-UNITOFMEASURENUMBEROFDECIMALS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.