ABAP Select data from SAP table IINSPRESULTTP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IINSPRESULTTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IINSPRESULTTP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IINSPRESULTTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IINSPRESULTTP TYPE STANDARD TABLE OF IINSPRESULTTP,
      WA_IINSPRESULTTP TYPE IINSPRESULTTP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IINSPRESULTTP> TYPE IINSPRESULTTP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IINSPRESULTTP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IINSPRESULTTP
  INTO TABLE IT_IINSPRESULTTP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IINSPRESULTTP
*  INTO TABLE @DATA(IT_IINSPRESULTTP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IINSPRESULTTP INDEX 1 INTO DATA(WA_IINSPRESULTTP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IINSPRESULTTP ASSIGNING <IINSPRESULTTP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IINSPRESULTTP>-MANDT = 1.
<IINSPRESULTTP>-INSPECTIONLOT = 1.
<IINSPRESULTTP>-INSPPLANOPERATIONINTERNALID = 1.
<IINSPRESULTTP>-INSPECTIONCHARACTERISTIC = 1.
<IINSPRESULTTP>-INSPECTOR = 1.
ENDLOOP.

LOOP AT IT_IINSPRESULTTP INTO WA_IINSPRESULTTP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IINSPRESULTTP-INSPECTIONRESULTSTATUS, sy-vline,
WA_IINSPRESULTTP-INSPECTIONRESULTATTRIBUTE, sy-vline,
WA_IINSPRESULTTP-INSPECTIONRESULTORIGIN, sy-vline,
WA_IINSPRESULTTP-INSPECTIONVALUATIONRESULT, sy-vline,
WA_IINSPRESULTTP-INSPRESULTDYNMODIFVALUATION, sy-vline,
WA_IINSPRESULTTP-INSPECTIONRESULTMEANVALUE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IINSPRESULTTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IINSPRESULTTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IINSPRESULTTP INTO WA_IINSPRESULTTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INSPECTIONLOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPRESULTTP-INSPECTIONLOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPRESULTTP-INSPECTIONLOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CHARCATTRIBUTECODEVERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPRESULTTP-CHARCATTRIBUTECODEVERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPRESULTTP-CHARCATTRIBUTECODEVERS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPRSLTFREEDEFINEDTESTEQUIP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPRESULTTP-INSPRSLTFREEDEFINEDTESTEQUIP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPRESULTTP-INSPRSLTFREEDEFINEDTESTEQUIP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONRESULTCODE2VERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPRESULTTP-INSPECTIONRESULTCODE2VERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPRESULTTP-INSPECTIONRESULTCODE2VERS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONRESULTCODE3VERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPRESULTTP-INSPECTIONRESULTCODE3VERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPRESULTTP-INSPECTIONRESULTCODE3VERS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONRESULTCODE4VERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPRESULTTP-INSPECTIONRESULTCODE4VERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPRESULTTP-INSPECTIONRESULTCODE4VERS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONRESULTCODE5VERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPRESULTTP-INSPECTIONRESULTCODE5VERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPRESULTTP-INSPECTIONRESULTCODE5VERS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IINSPRESULTTP_STR,
MANDT TYPE STRING,
INSPECTIONLOT TYPE STRING,
INSPPLANOPERATIONINTERNALID TYPE STRING,
INSPECTIONCHARACTERISTIC TYPE STRING,
INSPECTOR TYPE STRING,
INSPECTIONRESULTSTATUS TYPE STRING,
INSPECTIONRESULTATTRIBUTE TYPE STRING,
INSPECTIONRESULTORIGIN TYPE STRING,
INSPECTIONVALUATIONRESULT TYPE STRING,
INSPRESULTDYNMODIFVALUATION TYPE STRING,
INSPECTIONRESULTMEANVALUE TYPE STRING,
INSPRESULTFRMTDMEANVALUE TYPE STRING,
INSPECTIONRESULTHASMEANVALUE TYPE STRING,
INSPECTIONRESULTMAXIMUMVALUE TYPE STRING,
INSPRESULTFRMTDMAXIMUMVALUE TYPE STRING,
INSPRESULTHASMAXIMUMVALUE TYPE STRING,
INSPECTIONRESULTMINIMUMVALUE TYPE STRING,
INSPRESULTFRMTDMINIMUMVALUE TYPE STRING,
INSPRESULTHASMINIMUMVALUE TYPE STRING,
INSPECTIONRESULTORIGINALVALUE TYPE STRING,
INSPRESULTVALIDVALUESNUMBER TYPE STRING,
INSPRESULTNMBROFRECORDEDRSLTS TYPE STRING,
INSPECTIONRESULTTEXT TYPE STRING,
INSPECTIONRESULTHASLONGTEXT TYPE STRING,
CHARACTERISTICATTRIBUTECODEGRP TYPE STRING,
CHARACTERISTICATTRIBUTECODE TYPE STRING,
CHARCATTRIBUTECODEVERS TYPE STRING,
INSPRSLTFREEDEFINEDTESTEQUIP TYPE STRING,
INSPRSLTBELOWTOLERANCEVALSNMBR TYPE STRING,
INSPRSLTABOVETOLERANCEVALSNMBR TYPE STRING,
INSPRSLTNONCONFORMINGVALSNMBR TYPE STRING,
INSPRSLTABOVETOLERANCEFRACTION TYPE STRING,
INSPRSLTFRMTDABVTOLFRACTION TYPE STRING,
INSPRSLTBELOWTOLERANCEFRACTION TYPE STRING,
INSPRSLTFRMTDBELOWTOLFRACTION TYPE STRING,
INSPRESULTVARIANCE TYPE STRING,
INSPRESULTFRMTDVARIANCE TYPE STRING,
CHARACTERISTICATTRIBUTECATALOG TYPE STRING,
INSPECTIONRESULTCATALOG2 TYPE STRING,
INSPECTIONRESULTCATALOG3 TYPE STRING,
INSPECTIONRESULTCATALOG4 TYPE STRING,
INSPECTIONRESULTCATALOG5 TYPE STRING,
INSPECTIONRESULTCODE2 TYPE STRING,
INSPECTIONRESULTCODE3 TYPE STRING,
INSPECTIONRESULTCODE4 TYPE STRING,
INSPECTIONRESULTCODE5 TYPE STRING,
INSPECTIONRESULTCODE2VERS TYPE STRING,
INSPECTIONRESULTCODE3VERS TYPE STRING,
INSPECTIONRESULTCODE4VERS TYPE STRING,
INSPECTIONRESULTCODE5VERS TYPE STRING,
INSPECTIONRESULTCODEGROUP2 TYPE STRING,
INSPECTIONRESULTCODEGROUP3 TYPE STRING,
INSPECTIONRESULTCODEGROUP4 TYPE STRING,
INSPECTIONRESULTCODEGROUP5 TYPE STRING,
INSPECTIONPARTIALSAMPLESIZE TYPE STRING,
INSPECTIONSTARTDATE TYPE STRING,
INSPECTIONSTARTTIME TYPE STRING,
INSPECTIONENDDATE TYPE STRING,
INSPECTIONENDTIME TYPE STRING,
INSPECTIONNUMBEROFDEFECTS TYPE STRING,
DEFECTCLASS TYPE STRING,
CREATEDBYUSER TYPE STRING,
CREATIONDATE TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
LASTCHANGEDATE TYPE STRING,
CHANGEDTIME TYPE STRING,
CREATIONTIME TYPE STRING,
CHANGEDDATETIME TYPE STRING,
PLANT TYPE STRING,
ISBUSINESSPURPOSECOMPLETED TYPE STRING,
WORKCENTER TYPE STRING,
INSPECTIONLOTTYPE TYPE STRING,
MATLQUALITYAUTHORIZATIONGROUP TYPE STRING,END OF T_EKKO_STR. DATA: WA_IINSPRESULTTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IINSPRESULTTP_STR-MANDT sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONLOT sy-vline
WA_IINSPRESULTTP_STR-INSPPLANOPERATIONINTERNALID sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONCHARACTERISTIC sy-vline
WA_IINSPRESULTTP_STR-INSPECTOR sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTSTATUS sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTATTRIBUTE sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTORIGIN sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONVALUATIONRESULT sy-vline
WA_IINSPRESULTTP_STR-INSPRESULTDYNMODIFVALUATION sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTMEANVALUE sy-vline
WA_IINSPRESULTTP_STR-INSPRESULTFRMTDMEANVALUE sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTHASMEANVALUE sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTMAXIMUMVALUE sy-vline
WA_IINSPRESULTTP_STR-INSPRESULTFRMTDMAXIMUMVALUE sy-vline
WA_IINSPRESULTTP_STR-INSPRESULTHASMAXIMUMVALUE sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTMINIMUMVALUE sy-vline
WA_IINSPRESULTTP_STR-INSPRESULTFRMTDMINIMUMVALUE sy-vline
WA_IINSPRESULTTP_STR-INSPRESULTHASMINIMUMVALUE sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTORIGINALVALUE sy-vline
WA_IINSPRESULTTP_STR-INSPRESULTVALIDVALUESNUMBER sy-vline
WA_IINSPRESULTTP_STR-INSPRESULTNMBROFRECORDEDRSLTS sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTTEXT sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTHASLONGTEXT sy-vline
WA_IINSPRESULTTP_STR-CHARACTERISTICATTRIBUTECODEGRP sy-vline
WA_IINSPRESULTTP_STR-CHARACTERISTICATTRIBUTECODE sy-vline
WA_IINSPRESULTTP_STR-CHARCATTRIBUTECODEVERS sy-vline
WA_IINSPRESULTTP_STR-INSPRSLTFREEDEFINEDTESTEQUIP sy-vline
WA_IINSPRESULTTP_STR-INSPRSLTBELOWTOLERANCEVALSNMBR sy-vline
WA_IINSPRESULTTP_STR-INSPRSLTABOVETOLERANCEVALSNMBR sy-vline
WA_IINSPRESULTTP_STR-INSPRSLTNONCONFORMINGVALSNMBR sy-vline
WA_IINSPRESULTTP_STR-INSPRSLTABOVETOLERANCEFRACTION sy-vline
WA_IINSPRESULTTP_STR-INSPRSLTFRMTDABVTOLFRACTION sy-vline
WA_IINSPRESULTTP_STR-INSPRSLTBELOWTOLERANCEFRACTION sy-vline
WA_IINSPRESULTTP_STR-INSPRSLTFRMTDBELOWTOLFRACTION sy-vline
WA_IINSPRESULTTP_STR-INSPRESULTVARIANCE sy-vline
WA_IINSPRESULTTP_STR-INSPRESULTFRMTDVARIANCE sy-vline
WA_IINSPRESULTTP_STR-CHARACTERISTICATTRIBUTECATALOG sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTCATALOG2 sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTCATALOG3 sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTCATALOG4 sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTCATALOG5 sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTCODE2 sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTCODE3 sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTCODE4 sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTCODE5 sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTCODE2VERS sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTCODE3VERS sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTCODE4VERS sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTCODE5VERS sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTCODEGROUP2 sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTCODEGROUP3 sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTCODEGROUP4 sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONRESULTCODEGROUP5 sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONPARTIALSAMPLESIZE sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONSTARTDATE sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONSTARTTIME sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONENDDATE sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONENDTIME sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONNUMBEROFDEFECTS sy-vline
WA_IINSPRESULTTP_STR-DEFECTCLASS sy-vline
WA_IINSPRESULTTP_STR-CREATEDBYUSER sy-vline
WA_IINSPRESULTTP_STR-CREATIONDATE sy-vline
WA_IINSPRESULTTP_STR-LASTCHANGEDBYUSER sy-vline
WA_IINSPRESULTTP_STR-LASTCHANGEDATE sy-vline
WA_IINSPRESULTTP_STR-CHANGEDTIME sy-vline
WA_IINSPRESULTTP_STR-CREATIONTIME sy-vline
WA_IINSPRESULTTP_STR-CHANGEDDATETIME sy-vline
WA_IINSPRESULTTP_STR-PLANT sy-vline
WA_IINSPRESULTTP_STR-ISBUSINESSPURPOSECOMPLETED sy-vline
WA_IINSPRESULTTP_STR-WORKCENTER sy-vline
WA_IINSPRESULTTP_STR-INSPECTIONLOTTYPE sy-vline
WA_IINSPRESULTTP_STR-MATLQUALITYAUTHORIZATIONGROUP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.