ABAP Select data from SAP table IINSPCHARF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IINSPCHARF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IINSPCHARF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IINSPCHARF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IINSPCHARF TYPE STANDARD TABLE OF IINSPCHARF,
      WA_IINSPCHARF TYPE IINSPCHARF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IINSPCHARF> TYPE IINSPCHARF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IINSPCHARF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IINSPCHARF
  INTO TABLE IT_IINSPCHARF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IINSPCHARF
*  INTO TABLE @DATA(IT_IINSPCHARF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IINSPCHARF INDEX 1 INTO DATA(WA_IINSPCHARF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IINSPCHARF ASSIGNING <IINSPCHARF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IINSPCHARF>-MANDT = 1.
<IINSPCHARF>-INSPECTIONLOT = 1.
<IINSPCHARF>-INSPPLANOPERATIONINTERNALID = 1.
<IINSPCHARF>-INSPECTIONCHARACTERISTIC = 1.
<IINSPCHARF>-INSPECTIONSUBSETINTERNALID = 1.
ENDLOOP.

LOOP AT IT_IINSPCHARF INTO WA_IINSPCHARF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IINSPCHARF-INSPECTIONOPERATION, sy-vline,
WA_IINSPCHARF-INSPECTIONSPECIFICATIONPLANT, sy-vline,
WA_IINSPCHARF-INSPECTIONSPECIFICATION, sy-vline,
WA_IINSPCHARF-INSPECTIONSPECIFICATIONVERSION, sy-vline,
WA_IINSPCHARF-BILLOFOPERATIONSTYPE, sy-vline,
WA_IINSPCHARF-BILLOFOPERATIONSGROUP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IINSPCHARF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IINSPCHARF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IINSPCHARF INTO WA_IINSPCHARF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INSPECTIONLOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPCHARF-INSPECTIONLOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPCHARF-INSPECTIONLOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field INSPECTIONOPERATION CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_IINSPCHARF-INSPECTIONOPERATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPCHARF-INSPECTIONOPERATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONSPECIFICATION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPCHARF-INSPECTIONSPECIFICATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPCHARF-INSPECTIONSPECIFICATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONSPECIFICATIONVERSION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPCHARF-INSPECTIONSPECIFICATIONVERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPCHARF-INSPECTIONSPECIFICATIONVERSION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BILLOFOPERATIONSGROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPCHARF-BILLOFOPERATIONSGROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPCHARF-BILLOFOPERATIONSGROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BILLOFOPERATIONSVARIANT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPCHARF-BILLOFOPERATIONSVARIANT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPCHARF-BILLOFOPERATIONSVARIANT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IINSPCHARF-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPCHARF-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CUSTOMER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPCHARF-CUSTOMER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPCHARF-CUSTOMER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUPPLIER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPCHARF-SUPPLIER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPCHARF-SUPPLIER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field INSPECTIONSPECIFICATIONUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IINSPCHARF-INSPECTIONSPECIFICATIONUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPCHARF-INSPECTIONSPECIFICATIONUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IINSPCHARF_STR,
MANDT TYPE STRING,
INSPECTIONLOT TYPE STRING,
INSPPLANOPERATIONINTERNALID TYPE STRING,
INSPECTIONCHARACTERISTIC TYPE STRING,
INSPECTIONSUBSETINTERNALID TYPE STRING,
INSPECTIONOPERATION TYPE STRING,
INSPECTIONSPECIFICATIONPLANT TYPE STRING,
INSPECTIONSPECIFICATION TYPE STRING,
INSPECTIONSPECIFICATIONVERSION TYPE STRING,
BILLOFOPERATIONSTYPE TYPE STRING,
BILLOFOPERATIONSGROUP TYPE STRING,
BILLOFOPERATIONSUSAGE TYPE STRING,
BILLOFOPERATIONSVARIANT TYPE STRING,
BILLOFOPERATIONSCHANGESTATEID TYPE STRING,
MATERIAL TYPE STRING,
CUSTOMER TYPE STRING,
SUPPLIER TYPE STRING,
INSPECTIONLOTTYPE TYPE STRING,
PLANT TYPE STRING,
MATLQUALITYAUTHORIZATIONGROUP TYPE STRING,
INSPECTIONSPECIFICATIONUNIT TYPE STRING,
INSPCHAROPENSAMPLECOUNT TYPE STRING,
INSPCHARCACCEPTEDSAMPLECOUNT TYPE STRING,
INSPCHARREJECTEDSAMPLECOUNT TYPE STRING,
INSPECTIONRESULTMINIMUMVALUE TYPE STRING,
INSPECTIONRESULTMAXIMUMVALUE TYPE STRING,
INSPECTIONRESULTMEANVALUESUM TYPE STRING,
INSPRESULTVALIDVALUESNUMBER TYPE STRING,
INSPRSLTNONCONFORMINGVALSNMBR TYPE STRING,END OF T_EKKO_STR. DATA: WA_IINSPCHARF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IINSPCHARF_STR-MANDT sy-vline
WA_IINSPCHARF_STR-INSPECTIONLOT sy-vline
WA_IINSPCHARF_STR-INSPPLANOPERATIONINTERNALID sy-vline
WA_IINSPCHARF_STR-INSPECTIONCHARACTERISTIC sy-vline
WA_IINSPCHARF_STR-INSPECTIONSUBSETINTERNALID sy-vline
WA_IINSPCHARF_STR-INSPECTIONOPERATION sy-vline
WA_IINSPCHARF_STR-INSPECTIONSPECIFICATIONPLANT sy-vline
WA_IINSPCHARF_STR-INSPECTIONSPECIFICATION sy-vline
WA_IINSPCHARF_STR-INSPECTIONSPECIFICATIONVERSION sy-vline
WA_IINSPCHARF_STR-BILLOFOPERATIONSTYPE sy-vline
WA_IINSPCHARF_STR-BILLOFOPERATIONSGROUP sy-vline
WA_IINSPCHARF_STR-BILLOFOPERATIONSUSAGE sy-vline
WA_IINSPCHARF_STR-BILLOFOPERATIONSVARIANT sy-vline
WA_IINSPCHARF_STR-BILLOFOPERATIONSCHANGESTATEID sy-vline
WA_IINSPCHARF_STR-MATERIAL sy-vline
WA_IINSPCHARF_STR-CUSTOMER sy-vline
WA_IINSPCHARF_STR-SUPPLIER sy-vline
WA_IINSPCHARF_STR-INSPECTIONLOTTYPE sy-vline
WA_IINSPCHARF_STR-PLANT sy-vline
WA_IINSPCHARF_STR-MATLQUALITYAUTHORIZATIONGROUP sy-vline
WA_IINSPCHARF_STR-INSPECTIONSPECIFICATIONUNIT sy-vline
WA_IINSPCHARF_STR-INSPCHAROPENSAMPLECOUNT sy-vline
WA_IINSPCHARF_STR-INSPCHARCACCEPTEDSAMPLECOUNT sy-vline
WA_IINSPCHARF_STR-INSPCHARREJECTEDSAMPLECOUNT sy-vline
WA_IINSPCHARF_STR-INSPECTIONRESULTMINIMUMVALUE sy-vline
WA_IINSPCHARF_STR-INSPECTIONRESULTMAXIMUMVALUE sy-vline
WA_IINSPCHARF_STR-INSPECTIONRESULTMEANVALUESUM sy-vline
WA_IINSPCHARF_STR-INSPRESULTVALIDVALUESNUMBER sy-vline
WA_IINSPCHARF_STR-INSPRSLTNONCONFORMINGVALSNMBR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.