ABAP Select data from SAP table IINSPCHARCTP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IINSPCHARCTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IINSPCHARCTP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IINSPCHARCTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IINSPCHARCTP TYPE STANDARD TABLE OF IINSPCHARCTP,
      WA_IINSPCHARCTP TYPE IINSPCHARCTP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IINSPCHARCTP> TYPE IINSPCHARCTP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IINSPCHARCTP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IINSPCHARCTP
  INTO TABLE IT_IINSPCHARCTP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IINSPCHARCTP
*  INTO TABLE @DATA(IT_IINSPCHARCTP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IINSPCHARCTP INDEX 1 INTO DATA(WA_IINSPCHARCTP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IINSPCHARCTP ASSIGNING <IINSPCHARCTP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IINSPCHARCTP>-MANDT = 1.
<IINSPCHARCTP>-INSPECTIONLOT = 1.
<IINSPCHARCTP>-INSPPLANOPERATIONINTERNALID = 1.
<IINSPCHARCTP>-INSPECTIONCHARACTERISTIC = 1.
<IINSPCHARCTP>-INSPECTIONSPECIFICATIONTEXT = 1.
ENDLOOP.

LOOP AT IT_IINSPCHARCTP INTO WA_IINSPCHARCTP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IINSPCHARCTP-HASINSPCHARCPRTLSMPL, sy-vline,
WA_IINSPCHARCTP-INSPSPECISQUANTITATIVE, sy-vline,
WA_IINSPCHARCTP-INSPSPECISMEASUREDVALUERQD, sy-vline,
WA_IINSPCHARCTP-INSPSPECISSELECTEDSETREQUIRED, sy-vline,
WA_IINSPCHARCTP-INSPSPECISLONGTERMINSPECTION, sy-vline,
WA_IINSPCHARCTP-INSPSPECRECORDINGTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IINSPCHARCTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IINSPCHARCTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IINSPCHARCTP INTO WA_IINSPCHARCTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INSPECTIONLOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPCHARCTP-INSPECTIONLOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPCHARCTP-INSPECTIONLOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONMETHOD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPCHARCTP-INSPECTIONMETHOD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPCHARCTP-INSPECTIONMETHOD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONMETHODVERSION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPCHARCTP-INSPECTIONMETHODVERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPCHARCTP-INSPECTIONMETHODVERSION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONSPECIFICATION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPCHARCTP-INSPECTIONSPECIFICATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPCHARCTP-INSPECTIONSPECIFICATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONSPECIFICATIONVERSION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPCHARCTP-INSPECTIONSPECIFICATIONVERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPCHARCTP-INSPECTIONSPECIFICATIONVERSION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field INSPECTIONSPECIFICATIONUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IINSPCHARCTP-INSPECTIONSPECIFICATIONUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPCHARCTP-INSPECTIONSPECIFICATIONUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUANTITYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IINSPCHARCTP-QUANTITYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPCHARCTP-QUANTITYUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field INSPCHARACTERISTICSAMPLEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IINSPCHARCTP-INSPCHARACTERISTICSAMPLEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPCHARCTP-INSPCHARACTERISTICSAMPLEUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IINSPCHARCTP_STR,
MANDT TYPE STRING,
INSPECTIONLOT TYPE STRING,
INSPPLANOPERATIONINTERNALID TYPE STRING,
INSPECTIONCHARACTERISTIC TYPE STRING,
INSPECTIONSPECIFICATIONTEXT TYPE STRING,
HASINSPCHARCPRTLSMPL TYPE STRING,
INSPSPECISQUANTITATIVE TYPE STRING,
INSPSPECISMEASUREDVALUERQD TYPE STRING,
INSPSPECISSELECTEDSETREQUIRED TYPE STRING,
INSPSPECISLONGTERMINSPECTION TYPE STRING,
INSPSPECRECORDINGTYPE TYPE STRING,
INSPRESULTISDOCUMENTATIONRQD TYPE STRING,
INSPSPECCHARCCATEGORY TYPE STRING,
INSPSPECRESULTCALCULATION TYPE STRING,
INSPCHARCISNOTPLANNED TYPE STRING,
INSPECTIONMETHOD TYPE STRING,
INSPECTIONMETHODPLANT TYPE STRING,
INSPECTIONMETHODVERSION TYPE STRING,
INSPECTIONSPECIFICATIONPLANT TYPE STRING,
INSPECTIONSPECIFICATION TYPE STRING,
INSPECTIONSPECIFICATIONVERSION TYPE STRING,
INSPECTIONCHARACTERISTICSTATUS TYPE STRING,
INSPSPECDECIMALPLACES TYPE STRING,
INSPECTIONSPECIFICATIONUNIT TYPE STRING,
INSPSAMPLEVALUATIONRULE TYPE STRING,
QUANTITYUNIT TYPE STRING,
INSPCHARACTERISTICSAMPLESIZE TYPE STRING,
INSPCHARACTERISTICSAMPLEUNIT TYPE STRING,
INSPSPECSAMPLEQUANTITYFACTOR TYPE STRING,
INSPSPECTARGETVALUE TYPE STRING,
INSPSPECFRMTDTARGETVALUE TYPE STRING,
INSPSPECHASTARGETVALUE TYPE STRING,
INSPSPECUPPERLIMIT TYPE STRING,
INSPSPECFRMTDUPPERLIMIT TYPE STRING,
INSPSPECHASUPPERLIMIT TYPE STRING,
INSPSPECLOWERLIMIT TYPE STRING,
INSPSPECFRMTDLOWERLIMIT TYPE STRING,
INSPSPECHASLOWERLIMIT TYPE STRING,
INSPSPECIMPORTANCECODE TYPE STRING,
INSPLOTTESTEQUIPINTERNALID TYPE STRING,
SELECTEDCODESET TYPE STRING,
SELECTEDCODESETPLANT TYPE STRING,
INSPECTORQUALIFICATION TYPE STRING,
INSPSPECFORMULA1 TYPE STRING,
INSPSPECFORMULA2 TYPE STRING,
INSPSPECINFORMATIONFIELD1 TYPE STRING,
INSPSPECINFORMATIONFIELD2 TYPE STRING,
INSPSPECINFORMATIONFIELD3 TYPE STRING,
INSPSPECDEFECTCODEGRPRJCNLOWER TYPE STRING,
INSPSPECDEFECTCODERJCNLOWER TYPE STRING,
INSPSPECDEFECTCODEGRPRJCNUPPER TYPE STRING,
INSPSPECDEFECTCODERJCNUPPER TYPE STRING,
INSPSPECDEFECTCODEGRPREJECTION TYPE STRING,
INSPSPECDEFECTCODEREJECTION TYPE STRING,
INSPECTIONSCOPE TYPE STRING,
INSPSPECCONTROLINDICATORS TYPE STRING,
CHARACTERISTICATTRIBUTECATALOG TYPE STRING,
UNPLNDCHARCINSPSUBSETINTID TYPE STRING,
INSPLOTDYNAMICRULE TYPE STRING,
QUALITYLEVELINTERNALID TYPE STRING,
BOOCHARCGROUP TYPE STRING,
BOOCHARCSOURCECHARC TYPE STRING,
BOOCHARCGROUPDIVISION TYPE STRING,
PRODUCTIONORDEROPERATIONACTY TYPE STRING,
PRODUCTIONORDEROPACTYVERS TYPE STRING,
INSPCHARCCONFIRMATIONNUMBER TYPE STRING,
INSPCHARCCREATIONDATE TYPE STRING,
INSPSPECADDITIONALCATALOG2 TYPE STRING,
INSPSPECADDITIONALCATALOG3 TYPE STRING,
INSPSPECADDITIONALCATALOG4 TYPE STRING,
INSPSPECADDITIONALCATALOG5 TYPE STRING,
INSPSPECADDLSELDCODESETPLANT2 TYPE STRING,
INSPSPECADDLSELDCODESETPLANT3 TYPE STRING,
INSPSPECADDLSELDCODESETPLANT4 TYPE STRING,
INSPSPECADDLSELDCODESETPLANT5 TYPE STRING,
INSPSPECADDITIONALSELECTEDSET2 TYPE STRING,
INSPSPECADDITIONALCODEGROUP2 TYPE STRING,
INSPSPECADDITIONALSELECTEDSET3 TYPE STRING,
INSPSPECADDITIONALCODEGROUP3 TYPE STRING,
INSPSPECADDITIONALSELECTEDSET4 TYPE STRING,
INSPSPECADDITIONALCODEGROUP4 TYPE STRING,
INSPSPECADDITIONALSELECTEDSET5 TYPE STRING,
INSPSPECADDITIONALCODEGROUP5 TYPE STRING,
CHANGEDDATETIME TYPE STRING,
PLANT TYPE STRING,
ISBUSINESSPURPOSECOMPLETED TYPE STRING,
WORKCENTER TYPE STRING,
INSPECTIONLOTTYPE TYPE STRING,
MATLQUALITYAUTHORIZATIONGROUP TYPE STRING,END OF T_EKKO_STR. DATA: WA_IINSPCHARCTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IINSPCHARCTP_STR-MANDT sy-vline
WA_IINSPCHARCTP_STR-INSPECTIONLOT sy-vline
WA_IINSPCHARCTP_STR-INSPPLANOPERATIONINTERNALID sy-vline
WA_IINSPCHARCTP_STR-INSPECTIONCHARACTERISTIC sy-vline
WA_IINSPCHARCTP_STR-INSPECTIONSPECIFICATIONTEXT sy-vline
WA_IINSPCHARCTP_STR-HASINSPCHARCPRTLSMPL sy-vline
WA_IINSPCHARCTP_STR-INSPSPECISQUANTITATIVE sy-vline
WA_IINSPCHARCTP_STR-INSPSPECISMEASUREDVALUERQD sy-vline
WA_IINSPCHARCTP_STR-INSPSPECISSELECTEDSETREQUIRED sy-vline
WA_IINSPCHARCTP_STR-INSPSPECISLONGTERMINSPECTION sy-vline
WA_IINSPCHARCTP_STR-INSPSPECRECORDINGTYPE sy-vline
WA_IINSPCHARCTP_STR-INSPRESULTISDOCUMENTATIONRQD sy-vline
WA_IINSPCHARCTP_STR-INSPSPECCHARCCATEGORY sy-vline
WA_IINSPCHARCTP_STR-INSPSPECRESULTCALCULATION sy-vline
WA_IINSPCHARCTP_STR-INSPCHARCISNOTPLANNED sy-vline
WA_IINSPCHARCTP_STR-INSPECTIONMETHOD sy-vline
WA_IINSPCHARCTP_STR-INSPECTIONMETHODPLANT sy-vline
WA_IINSPCHARCTP_STR-INSPECTIONMETHODVERSION sy-vline
WA_IINSPCHARCTP_STR-INSPECTIONSPECIFICATIONPLANT sy-vline
WA_IINSPCHARCTP_STR-INSPECTIONSPECIFICATION sy-vline
WA_IINSPCHARCTP_STR-INSPECTIONSPECIFICATIONVERSION sy-vline
WA_IINSPCHARCTP_STR-INSPECTIONCHARACTERISTICSTATUS sy-vline
WA_IINSPCHARCTP_STR-INSPSPECDECIMALPLACES sy-vline
WA_IINSPCHARCTP_STR-INSPECTIONSPECIFICATIONUNIT sy-vline
WA_IINSPCHARCTP_STR-INSPSAMPLEVALUATIONRULE sy-vline
WA_IINSPCHARCTP_STR-QUANTITYUNIT sy-vline
WA_IINSPCHARCTP_STR-INSPCHARACTERISTICSAMPLESIZE sy-vline
WA_IINSPCHARCTP_STR-INSPCHARACTERISTICSAMPLEUNIT sy-vline
WA_IINSPCHARCTP_STR-INSPSPECSAMPLEQUANTITYFACTOR sy-vline
WA_IINSPCHARCTP_STR-INSPSPECTARGETVALUE sy-vline
WA_IINSPCHARCTP_STR-INSPSPECFRMTDTARGETVALUE sy-vline
WA_IINSPCHARCTP_STR-INSPSPECHASTARGETVALUE sy-vline
WA_IINSPCHARCTP_STR-INSPSPECUPPERLIMIT sy-vline
WA_IINSPCHARCTP_STR-INSPSPECFRMTDUPPERLIMIT sy-vline
WA_IINSPCHARCTP_STR-INSPSPECHASUPPERLIMIT sy-vline
WA_IINSPCHARCTP_STR-INSPSPECLOWERLIMIT sy-vline
WA_IINSPCHARCTP_STR-INSPSPECFRMTDLOWERLIMIT sy-vline
WA_IINSPCHARCTP_STR-INSPSPECHASLOWERLIMIT sy-vline
WA_IINSPCHARCTP_STR-INSPSPECIMPORTANCECODE sy-vline
WA_IINSPCHARCTP_STR-INSPLOTTESTEQUIPINTERNALID sy-vline
WA_IINSPCHARCTP_STR-SELECTEDCODESET sy-vline
WA_IINSPCHARCTP_STR-SELECTEDCODESETPLANT sy-vline
WA_IINSPCHARCTP_STR-INSPECTORQUALIFICATION sy-vline
WA_IINSPCHARCTP_STR-INSPSPECFORMULA1 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECFORMULA2 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECINFORMATIONFIELD1 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECINFORMATIONFIELD2 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECINFORMATIONFIELD3 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECDEFECTCODEGRPRJCNLOWER sy-vline
WA_IINSPCHARCTP_STR-INSPSPECDEFECTCODERJCNLOWER sy-vline
WA_IINSPCHARCTP_STR-INSPSPECDEFECTCODEGRPRJCNUPPER sy-vline
WA_IINSPCHARCTP_STR-INSPSPECDEFECTCODERJCNUPPER sy-vline
WA_IINSPCHARCTP_STR-INSPSPECDEFECTCODEGRPREJECTION sy-vline
WA_IINSPCHARCTP_STR-INSPSPECDEFECTCODEREJECTION sy-vline
WA_IINSPCHARCTP_STR-INSPECTIONSCOPE sy-vline
WA_IINSPCHARCTP_STR-INSPSPECCONTROLINDICATORS sy-vline
WA_IINSPCHARCTP_STR-CHARACTERISTICATTRIBUTECATALOG sy-vline
WA_IINSPCHARCTP_STR-UNPLNDCHARCINSPSUBSETINTID sy-vline
WA_IINSPCHARCTP_STR-INSPLOTDYNAMICRULE sy-vline
WA_IINSPCHARCTP_STR-QUALITYLEVELINTERNALID sy-vline
WA_IINSPCHARCTP_STR-BOOCHARCGROUP sy-vline
WA_IINSPCHARCTP_STR-BOOCHARCSOURCECHARC sy-vline
WA_IINSPCHARCTP_STR-BOOCHARCGROUPDIVISION sy-vline
WA_IINSPCHARCTP_STR-PRODUCTIONORDEROPERATIONACTY sy-vline
WA_IINSPCHARCTP_STR-PRODUCTIONORDEROPACTYVERS sy-vline
WA_IINSPCHARCTP_STR-INSPCHARCCONFIRMATIONNUMBER sy-vline
WA_IINSPCHARCTP_STR-INSPCHARCCREATIONDATE sy-vline
WA_IINSPCHARCTP_STR-INSPSPECADDITIONALCATALOG2 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECADDITIONALCATALOG3 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECADDITIONALCATALOG4 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECADDITIONALCATALOG5 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECADDLSELDCODESETPLANT2 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECADDLSELDCODESETPLANT3 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECADDLSELDCODESETPLANT4 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECADDLSELDCODESETPLANT5 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECADDITIONALSELECTEDSET2 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECADDITIONALCODEGROUP2 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECADDITIONALSELECTEDSET3 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECADDITIONALCODEGROUP3 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECADDITIONALSELECTEDSET4 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECADDITIONALCODEGROUP4 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECADDITIONALSELECTEDSET5 sy-vline
WA_IINSPCHARCTP_STR-INSPSPECADDITIONALCODEGROUP5 sy-vline
WA_IINSPCHARCTP_STR-CHANGEDDATETIME sy-vline
WA_IINSPCHARCTP_STR-PLANT sy-vline
WA_IINSPCHARCTP_STR-ISBUSINESSPURPOSECOMPLETED sy-vline
WA_IINSPCHARCTP_STR-WORKCENTER sy-vline
WA_IINSPCHARCTP_STR-INSPECTIONLOTTYPE sy-vline
WA_IINSPCHARCTP_STR-MATLQUALITYAUTHORIZATIONGROUP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.