ABAP Select data from SAP table IFMCAE1FIKPF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IFMCAE1FIKPF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IFMCAE1FIKPF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IFMCAE1FIKPF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IFMCAE1FIKPF TYPE STANDARD TABLE OF IFMCAE1FIKPF,
      WA_IFMCAE1FIKPF TYPE IFMCAE1FIKPF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IFMCAE1FIKPF> TYPE IFMCAE1FIKPF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IFMCAE1FIKPF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IFMCAE1FIKPF
  INTO TABLE IT_IFMCAE1FIKPF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IFMCAE1FIKPF
*  INTO TABLE @DATA(IT_IFMCAE1FIKPF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IFMCAE1FIKPF INDEX 1 INTO DATA(WA_IFMCAE1FIKPF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IFMCAE1FIKPF ASSIGNING <IFMCAE1FIKPF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IFMCAE1FIKPF>-BUKRS = 1.
<IFMCAE1FIKPF>-BELNR = 1.
<IFMCAE1FIKPF>-GJAHR = 1.
<IFMCAE1FIKPF>-BLART = 1.
<IFMCAE1FIKPF>-BLDAT = 1.
ENDLOOP.

LOOP AT IT_IFMCAE1FIKPF INTO WA_IFMCAE1FIKPF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IFMCAE1FIKPF-BUDAT, sy-vline,
WA_IFMCAE1FIKPF-MONAT, sy-vline,
WA_IFMCAE1FIKPF-WWERT, sy-vline,
WA_IFMCAE1FIKPF-USNAM, sy-vline,
WA_IFMCAE1FIKPF-TCODE, sy-vline,
WA_IFMCAE1FIKPF-BVORG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IFMCAE1FIKPF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IFMCAE1FIKPF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IFMCAE1FIKPF INTO WA_IFMCAE1FIKPF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IFMCAE1FIKPF_STR,
BUKRS TYPE STRING,
BELNR TYPE STRING,
GJAHR TYPE STRING,
BLART TYPE STRING,
BLDAT TYPE STRING,
BUDAT TYPE STRING,
MONAT TYPE STRING,
WWERT TYPE STRING,
USNAM TYPE STRING,
TCODE TYPE STRING,
BVORG TYPE STRING,
XBLNR TYPE STRING,
BKTXT TYPE STRING,
WAERS TYPE STRING,
KURSF TYPE STRING,
GLVOR TYPE STRING,
AWTYP TYPE STRING,
AWREF TYPE STRING,
AWORG TYPE STRING,
FIKRS TYPE STRING,
HWAER TYPE STRING,
HWAE2 TYPE STRING,
HWAE3 TYPE STRING,
KURS2 TYPE STRING,
KURS3 TYPE STRING,
BASW2 TYPE STRING,
BASW3 TYPE STRING,
UMRD2 TYPE STRING,
UMRD3 TYPE STRING,
CURT2 TYPE STRING,
CURT3 TYPE STRING,
AUSBK TYPE STRING,
AWSYS TYPE STRING,
LOTKZ TYPE STRING,
BUKRS_SND TYPE STRING,
FILTER TYPE STRING,
KURSF_M TYPE STRING,
KURS2_M TYPE STRING,
KURS3_M TYPE STRING,
BSTAT TYPE STRING,
BRNCH TYPE STRING,
NUMPG TYPE STRING,
ADISC TYPE STRING,
STBLG TYPE STRING,
STJAH TYPE STRING,
AWTYP_REV TYPE STRING,
AWREF_REV TYPE STRING,
AWORG_REV TYPE STRING,
RESERVE TYPE STRING,
XREF1_HD TYPE STRING,
XREF2_HD TYPE STRING,END OF T_EKKO_STR. DATA: WA_IFMCAE1FIKPF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IFMCAE1FIKPF_STR-BUKRS sy-vline
WA_IFMCAE1FIKPF_STR-BELNR sy-vline
WA_IFMCAE1FIKPF_STR-GJAHR sy-vline
WA_IFMCAE1FIKPF_STR-BLART sy-vline
WA_IFMCAE1FIKPF_STR-BLDAT sy-vline
WA_IFMCAE1FIKPF_STR-BUDAT sy-vline
WA_IFMCAE1FIKPF_STR-MONAT sy-vline
WA_IFMCAE1FIKPF_STR-WWERT sy-vline
WA_IFMCAE1FIKPF_STR-USNAM sy-vline
WA_IFMCAE1FIKPF_STR-TCODE sy-vline
WA_IFMCAE1FIKPF_STR-BVORG sy-vline
WA_IFMCAE1FIKPF_STR-XBLNR sy-vline
WA_IFMCAE1FIKPF_STR-BKTXT sy-vline
WA_IFMCAE1FIKPF_STR-WAERS sy-vline
WA_IFMCAE1FIKPF_STR-KURSF sy-vline
WA_IFMCAE1FIKPF_STR-GLVOR sy-vline
WA_IFMCAE1FIKPF_STR-AWTYP sy-vline
WA_IFMCAE1FIKPF_STR-AWREF sy-vline
WA_IFMCAE1FIKPF_STR-AWORG sy-vline
WA_IFMCAE1FIKPF_STR-FIKRS sy-vline
WA_IFMCAE1FIKPF_STR-HWAER sy-vline
WA_IFMCAE1FIKPF_STR-HWAE2 sy-vline
WA_IFMCAE1FIKPF_STR-HWAE3 sy-vline
WA_IFMCAE1FIKPF_STR-KURS2 sy-vline
WA_IFMCAE1FIKPF_STR-KURS3 sy-vline
WA_IFMCAE1FIKPF_STR-BASW2 sy-vline
WA_IFMCAE1FIKPF_STR-BASW3 sy-vline
WA_IFMCAE1FIKPF_STR-UMRD2 sy-vline
WA_IFMCAE1FIKPF_STR-UMRD3 sy-vline
WA_IFMCAE1FIKPF_STR-CURT2 sy-vline
WA_IFMCAE1FIKPF_STR-CURT3 sy-vline
WA_IFMCAE1FIKPF_STR-AUSBK sy-vline
WA_IFMCAE1FIKPF_STR-AWSYS sy-vline
WA_IFMCAE1FIKPF_STR-LOTKZ sy-vline
WA_IFMCAE1FIKPF_STR-BUKRS_SND sy-vline
WA_IFMCAE1FIKPF_STR-FILTER sy-vline
WA_IFMCAE1FIKPF_STR-KURSF_M sy-vline
WA_IFMCAE1FIKPF_STR-KURS2_M sy-vline
WA_IFMCAE1FIKPF_STR-KURS3_M sy-vline
WA_IFMCAE1FIKPF_STR-BSTAT sy-vline
WA_IFMCAE1FIKPF_STR-BRNCH sy-vline
WA_IFMCAE1FIKPF_STR-NUMPG sy-vline
WA_IFMCAE1FIKPF_STR-ADISC sy-vline
WA_IFMCAE1FIKPF_STR-STBLG sy-vline
WA_IFMCAE1FIKPF_STR-STJAH sy-vline
WA_IFMCAE1FIKPF_STR-AWTYP_REV sy-vline
WA_IFMCAE1FIKPF_STR-AWREF_REV sy-vline
WA_IFMCAE1FIKPF_STR-AWORG_REV sy-vline
WA_IFMCAE1FIKPF_STR-RESERVE sy-vline
WA_IFMCAE1FIKPF_STR-XREF1_HD sy-vline
WA_IFMCAE1FIKPF_STR-XREF2_HD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.