ABAP Select data from SAP table IFLOT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IFLOT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IFLOT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IFLOT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IFLOT TYPE STANDARD TABLE OF IFLOT,
      WA_IFLOT TYPE IFLOT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IFLOT> TYPE IFLOT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IFLOT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IFLOT
  INTO TABLE IT_IFLOT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IFLOT
*  INTO TABLE @DATA(IT_IFLOT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IFLOT INDEX 1 INTO DATA(WA_IFLOT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IFLOT ASSIGNING <IFLOT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IFLOT>-MANDT = 1.
<IFLOT>-TPLNR = 1.
<IFLOT>-MLANG = 1.
<IFLOT>-TPLKZ = 1.
<IFLOT>-FLTYP = 1.
ENDLOOP.

LOOP AT IT_IFLOT INTO WA_IFLOT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IFLOT-TPLMA, sy-vline,
WA_IFLOT-ERDAT, sy-vline,
WA_IFLOT-ERNAM, sy-vline,
WA_IFLOT-AEDAT, sy-vline,
WA_IFLOT-AENAM, sy-vline,
WA_IFLOT-DATAB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IFLOT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IFLOT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IFLOT INTO WA_IFLOT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TPLNR, internal->external for field TPLNR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_IFLOT-TPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IFLOT-TPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field MLANG CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_IFLOT-MLANG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IFLOT-MLANG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLMA CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_IFLOT-TPLMA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IFLOT-TPLMA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field SUBMT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IFLOT-SUBMT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IFLOT-SUBMT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GEWEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IFLOT-GEWEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IFLOT-GEWEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field BAUJJ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_IFLOT-BAUJJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IFLOT-BAUJJ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field EMATN CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IFLOT-EMATN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IFLOT-EMATN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TMPLA, internal->external for field TSEGTP CALL FUNCTION 'CONVERSION_EXIT_TMPLA_OUTPUT' EXPORTING input = WA_IFLOT-TSEGTP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IFLOT-TSEGTP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IFLOT_STR,
MANDT TYPE STRING,
TPLNR TYPE STRING,
MLANG TYPE STRING,
TPLKZ TYPE STRING,
FLTYP TYPE STRING,
TPLMA TYPE STRING,
ERDAT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
DATAB TYPE STRING,
BEGRU TYPE STRING,
TRPNR TYPE STRING,
PSTAE TYPE STRING,
STNAM TYPE STRING,
LVORM TYPE STRING,
SUBMT TYPE STRING,
SUBMTI TYPE STRING,
MAPAR TYPE STRING,
MAPARI TYPE STRING,
IEQUI TYPE STRING,
IEQUII TYPE STRING,
EINZL TYPE STRING,
EINZLI TYPE STRING,
IWERK TYPE STRING,
IWERKI TYPE STRING,
INGRP TYPE STRING,
INGRPI TYPE STRING,
PM_OBJTY TYPE STRING,
LGWID TYPE STRING,
LGWIDI TYPE STRING,
RBNR TYPE STRING,
RBNR_I TYPE STRING,
ILOAN TYPE STRING,
OBJNR TYPE STRING,
POSNR TYPE STRING,
ISTYP TYPE STRING,
PREMS TYPE STRING,
EQART TYPE STRING,
INVNR TYPE STRING,
GROES TYPE STRING,
BRGEW TYPE STRING,
GEWEI TYPE STRING,
ANSWT TYPE STRING,
WAERS TYPE STRING,
ANSDT TYPE STRING,
HERST TYPE STRING,
HERLD TYPE STRING,
BAUJJ TYPE STRING,
BAUMM TYPE STRING,
TYPBZ TYPE STRING,
EMATN TYPE STRING,
SERGE TYPE STRING,
HANDLE TYPE STRING,
TSEGTP TYPE STRING,
CHANGEDDATETIME TYPE STRING,
ENDOFUSE TYPE STRING,
DUMMY_IFLOT_INCL_EEW_PS TYPE STRING,
FLLB_DUTY TYPE STRING,
FLLB_HIDE TYPE STRING,
IFLOT_SRTYPE TYPE STRING,
IFLOT_SNTYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_IFLOT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IFLOT_STR-MANDT sy-vline
WA_IFLOT_STR-TPLNR sy-vline
WA_IFLOT_STR-MLANG sy-vline
WA_IFLOT_STR-TPLKZ sy-vline
WA_IFLOT_STR-FLTYP sy-vline
WA_IFLOT_STR-TPLMA sy-vline
WA_IFLOT_STR-ERDAT sy-vline
WA_IFLOT_STR-ERNAM sy-vline
WA_IFLOT_STR-AEDAT sy-vline
WA_IFLOT_STR-AENAM sy-vline
WA_IFLOT_STR-DATAB sy-vline
WA_IFLOT_STR-BEGRU sy-vline
WA_IFLOT_STR-TRPNR sy-vline
WA_IFLOT_STR-PSTAE sy-vline
WA_IFLOT_STR-STNAM sy-vline
WA_IFLOT_STR-LVORM sy-vline
WA_IFLOT_STR-SUBMT sy-vline
WA_IFLOT_STR-SUBMTI sy-vline
WA_IFLOT_STR-MAPAR sy-vline
WA_IFLOT_STR-MAPARI sy-vline
WA_IFLOT_STR-IEQUI sy-vline
WA_IFLOT_STR-IEQUII sy-vline
WA_IFLOT_STR-EINZL sy-vline
WA_IFLOT_STR-EINZLI sy-vline
WA_IFLOT_STR-IWERK sy-vline
WA_IFLOT_STR-IWERKI sy-vline
WA_IFLOT_STR-INGRP sy-vline
WA_IFLOT_STR-INGRPI sy-vline
WA_IFLOT_STR-PM_OBJTY sy-vline
WA_IFLOT_STR-LGWID sy-vline
WA_IFLOT_STR-LGWIDI sy-vline
WA_IFLOT_STR-RBNR sy-vline
WA_IFLOT_STR-RBNR_I sy-vline
WA_IFLOT_STR-ILOAN sy-vline
WA_IFLOT_STR-OBJNR sy-vline
WA_IFLOT_STR-POSNR sy-vline
WA_IFLOT_STR-ISTYP sy-vline
WA_IFLOT_STR-PREMS sy-vline
WA_IFLOT_STR-EQART sy-vline
WA_IFLOT_STR-INVNR sy-vline
WA_IFLOT_STR-GROES sy-vline
WA_IFLOT_STR-BRGEW sy-vline
WA_IFLOT_STR-GEWEI sy-vline
WA_IFLOT_STR-ANSWT sy-vline
WA_IFLOT_STR-WAERS sy-vline
WA_IFLOT_STR-ANSDT sy-vline
WA_IFLOT_STR-HERST sy-vline
WA_IFLOT_STR-HERLD sy-vline
WA_IFLOT_STR-BAUJJ sy-vline
WA_IFLOT_STR-BAUMM sy-vline
WA_IFLOT_STR-TYPBZ sy-vline
WA_IFLOT_STR-EMATN sy-vline
WA_IFLOT_STR-SERGE sy-vline
WA_IFLOT_STR-HANDLE sy-vline
WA_IFLOT_STR-TSEGTP sy-vline
WA_IFLOT_STR-CHANGEDDATETIME sy-vline
WA_IFLOT_STR-ENDOFUSE sy-vline
WA_IFLOT_STR-DUMMY_IFLOT_INCL_EEW_PS sy-vline
WA_IFLOT_STR-FLLB_DUTY sy-vline
WA_IFLOT_STR-FLLB_HIDE sy-vline
WA_IFLOT_STR-IFLOT_SRTYPE sy-vline
WA_IFLOT_STR-IFLOT_SNTYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.