ABAP Select data from SAP table IEUOCHKGRPINVCHK into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IEUOCHKGRPINVCHK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IEUOCHKGRPINVCHK. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IEUOCHKGRPINVCHK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IEUOCHKGRPINVCHK TYPE STANDARD TABLE OF IEUOCHKGRPINVCHK,
      WA_IEUOCHKGRPINVCHK TYPE IEUOCHKGRPINVCHK,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IEUOCHKGRPINVCHK> TYPE IEUOCHKGRPINVCHK.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IEUOCHKGRPINVCHK.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IEUOCHKGRPINVCHK
  INTO TABLE IT_IEUOCHKGRPINVCHK.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IEUOCHKGRPINVCHK
*  INTO TABLE @DATA(IT_IEUOCHKGRPINVCHK2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IEUOCHKGRPINVCHK INDEX 1 INTO DATA(WA_IEUOCHKGRPINVCHK2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IEUOCHKGRPINVCHK ASSIGNING <IEUOCHKGRPINVCHK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IEUOCHKGRPINVCHK>-MANDT = 1.
<IEUOCHKGRPINVCHK>-UTILSOUTSRTGCHECKGRPFORINVCG = 1.
<IEUOCHKGRPINVCHK>-UTILSINVCGCHKSEQUENCENUMBER = 1.
<IEUOCHKGRPINVCHK>-UTILITIESINVOICINGCHECK = 1.
<IEUOCHKGRPINVCHK>-UTILSINVOICINGCHECKVALUE1 = 1.
ENDLOOP.

LOOP AT IT_IEUOCHKGRPINVCHK INTO WA_IEUOCHKGRPINVCHK.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IEUOCHKGRPINVCHK-UTILSINVOICINGCHECKVALUE2, sy-vline,
WA_IEUOCHKGRPINVCHK-UTILSINVOICINGCHECKVALUE3, sy-vline,
WA_IEUOCHKGRPINVCHK-UTILSINVOICINGCHECKVALUE4, sy-vline,
WA_IEUOCHKGRPINVCHK-UTILSINVOICINGCHECKTEXT, sy-vline,
ENDLOOP. *Add any further fields from structure WA_IEUOCHKGRPINVCHK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IEUOCHKGRPINVCHK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IEUOCHKGRPINVCHK INTO WA_IEUOCHKGRPINVCHK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IEUOCHKGRPINVCHK_STR,
MANDT TYPE STRING,
UTILSOUTSRTGCHECKGRPFORINVCG TYPE STRING,
UTILSINVCGCHKSEQUENCENUMBER TYPE STRING,
UTILITIESINVOICINGCHECK TYPE STRING,
UTILSINVOICINGCHECKVALUE1 TYPE STRING,
UTILSINVOICINGCHECKVALUE2 TYPE STRING,
UTILSINVOICINGCHECKVALUE3 TYPE STRING,
UTILSINVOICINGCHECKVALUE4 TYPE STRING,
UTILSINVOICINGCHECKTEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_IEUOCHKGRPINVCHK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IEUOCHKGRPINVCHK_STR-MANDT sy-vline
WA_IEUOCHKGRPINVCHK_STR-UTILSOUTSRTGCHECKGRPFORINVCG sy-vline
WA_IEUOCHKGRPINVCHK_STR-UTILSINVCGCHKSEQUENCENUMBER sy-vline
WA_IEUOCHKGRPINVCHK_STR-UTILITIESINVOICINGCHECK sy-vline
WA_IEUOCHKGRPINVCHK_STR-UTILSINVOICINGCHECKVALUE1 sy-vline
WA_IEUOCHKGRPINVCHK_STR-UTILSINVOICINGCHECKVALUE2 sy-vline
WA_IEUOCHKGRPINVCHK_STR-UTILSINVOICINGCHECKVALUE3 sy-vline
WA_IEUOCHKGRPINVCHK_STR-UTILSINVOICINGCHECKVALUE4 sy-vline
WA_IEUOCHKGRPINVCHK_STR-UTILSINVOICINGCHECKTEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.