ABAP Select data from SAP table IEQINSTALL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IEQINSTALL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IEQINSTALL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IEQINSTALL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IEQINSTALL TYPE STANDARD TABLE OF IEQINSTALL,
      WA_IEQINSTALL TYPE IEQINSTALL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IEQINSTALL> TYPE IEQINSTALL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IEQINSTALL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IEQINSTALL
  INTO TABLE IT_IEQINSTALL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IEQINSTALL
*  INTO TABLE @DATA(IT_IEQINSTALL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IEQINSTALL INDEX 1 INTO DATA(WA_IEQINSTALL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IEQINSTALL ASSIGNING <IEQINSTALL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IEQINSTALL>-MANDT = 1.
<IEQINSTALL>-OBJTP = 1.
<IEQINSTALL>-TPLNR = 1.
<IEQINSTALL>-PLTXT = 1.
<IEQINSTALL>-TPLKZ = 1.
ENDLOOP.

LOOP AT IT_IEQINSTALL INTO WA_IEQINSTALL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IEQINSTALL-EDITM, sy-vline,
WA_IEQINSTALL-HIERA, sy-vline,
WA_IEQINSTALL-HEQNR, sy-vline,
WA_IEQINSTALL-HEQTX, sy-vline,
WA_IEQINSTALL-EQUNR, sy-vline,
WA_IEQINSTALL-EQKTX, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IEQINSTALL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IEQINSTALL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IEQINSTALL INTO WA_IEQINSTALL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TPLNR, internal->external for field TPLNR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_IEQINSTALL-TPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEQINSTALL-TPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HEQNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEQINSTALL-HEQNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEQINSTALL-HEQNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEQINSTALL-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEQINSTALL-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQNEW CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEQINSTALL-EQNEW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEQINSTALL-EQNEW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HEOLD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEQINSTALL-HEOLD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEQINSTALL-HEOLD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HENEW CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEQINSTALL-HENEW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEQINSTALL-HENEW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IEQINSTALL-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEQINSTALL-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SERNR CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_IEQINSTALL-SERNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEQINSTALL-SERNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field SUBMT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IEQINSTALL-SUBMT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEQINSTALL-SUBMT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEQINSTALL-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEQINSTALL-KOSTL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IEQINSTALL_STR,
MANDT TYPE STRING,
OBJTP TYPE STRING,
TPLNR TYPE STRING,
PLTXT TYPE STRING,
TPLKZ TYPE STRING,
EDITM TYPE STRING,
HIERA TYPE STRING,
HEQNR TYPE STRING,
HEQTX TYPE STRING,
EQUNR TYPE STRING,
EQKTX TYPE STRING,
EQNEW TYPE STRING,
EQNTX TYPE STRING,
HSTUF TYPE STRING,
HSTPS TYPE STRING,
HEOLD TYPE STRING,
EQTXO TYPE STRING,
PSOLD TYPE STRING,
HENEW TYPE STRING,
EQTXN TYPE STRING,
PSNEW TYPE STRING,
SELKZ TYPE STRING,
HMORE TYPE STRING,
INFO_ART TYPE STRING,
DATA_SEL TYPE STRING,
APAGE TYPE STRING,
LPAGE TYPE STRING,
INHER_FL TYPE STRING,
INHER_EQ TYPE STRING,
INHER_NO TYPE STRING,
DATUM TYPE STRING,
UZEIT TYPE STRING,
FCODE TYPE STRING,
EQART TYPE STRING,
HERST TYPE STRING,
TYPBZ TYPE STRING,
MATNR TYPE STRING,
SERNR TYPE STRING,
IWERK TYPE STRING,
INGRP TYPE STRING,
SUBMT TYPE STRING,
TIDNR TYPE STRING,
ABCKZ TYPE STRING,
EQFNR TYPE STRING,
SWERK TYPE STRING,
STORT TYPE STRING,
MSGRP TYPE STRING,
BEBER TYPE STRING,
KOKRS TYPE STRING,
BUKRS TYPE STRING,
GEWRK TYPE STRING,
PPSID TYPE STRING,
KOSTL TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
VKBUR TYPE STRING,
VKGRP TYPE STRING,
DATDN TYPE STRING,
UZTDN TYPE STRING,END OF T_EKKO_STR. DATA: WA_IEQINSTALL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IEQINSTALL_STR-MANDT sy-vline
WA_IEQINSTALL_STR-OBJTP sy-vline
WA_IEQINSTALL_STR-TPLNR sy-vline
WA_IEQINSTALL_STR-PLTXT sy-vline
WA_IEQINSTALL_STR-TPLKZ sy-vline
WA_IEQINSTALL_STR-EDITM sy-vline
WA_IEQINSTALL_STR-HIERA sy-vline
WA_IEQINSTALL_STR-HEQNR sy-vline
WA_IEQINSTALL_STR-HEQTX sy-vline
WA_IEQINSTALL_STR-EQUNR sy-vline
WA_IEQINSTALL_STR-EQKTX sy-vline
WA_IEQINSTALL_STR-EQNEW sy-vline
WA_IEQINSTALL_STR-EQNTX sy-vline
WA_IEQINSTALL_STR-HSTUF sy-vline
WA_IEQINSTALL_STR-HSTPS sy-vline
WA_IEQINSTALL_STR-HEOLD sy-vline
WA_IEQINSTALL_STR-EQTXO sy-vline
WA_IEQINSTALL_STR-PSOLD sy-vline
WA_IEQINSTALL_STR-HENEW sy-vline
WA_IEQINSTALL_STR-EQTXN sy-vline
WA_IEQINSTALL_STR-PSNEW sy-vline
WA_IEQINSTALL_STR-SELKZ sy-vline
WA_IEQINSTALL_STR-HMORE sy-vline
WA_IEQINSTALL_STR-INFO_ART sy-vline
WA_IEQINSTALL_STR-DATA_SEL sy-vline
WA_IEQINSTALL_STR-APAGE sy-vline
WA_IEQINSTALL_STR-LPAGE sy-vline
WA_IEQINSTALL_STR-INHER_FL sy-vline
WA_IEQINSTALL_STR-INHER_EQ sy-vline
WA_IEQINSTALL_STR-INHER_NO sy-vline
WA_IEQINSTALL_STR-DATUM sy-vline
WA_IEQINSTALL_STR-UZEIT sy-vline
WA_IEQINSTALL_STR-FCODE sy-vline
WA_IEQINSTALL_STR-EQART sy-vline
WA_IEQINSTALL_STR-HERST sy-vline
WA_IEQINSTALL_STR-TYPBZ sy-vline
WA_IEQINSTALL_STR-MATNR sy-vline
WA_IEQINSTALL_STR-SERNR sy-vline
WA_IEQINSTALL_STR-IWERK sy-vline
WA_IEQINSTALL_STR-INGRP sy-vline
WA_IEQINSTALL_STR-SUBMT sy-vline
WA_IEQINSTALL_STR-TIDNR sy-vline
WA_IEQINSTALL_STR-ABCKZ sy-vline
WA_IEQINSTALL_STR-EQFNR sy-vline
WA_IEQINSTALL_STR-SWERK sy-vline
WA_IEQINSTALL_STR-STORT sy-vline
WA_IEQINSTALL_STR-MSGRP sy-vline
WA_IEQINSTALL_STR-BEBER sy-vline
WA_IEQINSTALL_STR-KOKRS sy-vline
WA_IEQINSTALL_STR-BUKRS sy-vline
WA_IEQINSTALL_STR-GEWRK sy-vline
WA_IEQINSTALL_STR-PPSID sy-vline
WA_IEQINSTALL_STR-KOSTL sy-vline
WA_IEQINSTALL_STR-VKORG sy-vline
WA_IEQINSTALL_STR-VTWEG sy-vline
WA_IEQINSTALL_STR-SPART sy-vline
WA_IEQINSTALL_STR-VKBUR sy-vline
WA_IEQINSTALL_STR-VKGRP sy-vline
WA_IEQINSTALL_STR-DATDN sy-vline
WA_IEQINSTALL_STR-UZTDN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.