ABAP Select data from SAP table IEMBWIPICINFOTP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IEMBWIPICINFOTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IEMBWIPICINFOTP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IEMBWIPICINFOTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IEMBWIPICINFOTP TYPE STANDARD TABLE OF IEMBWIPICINFOTP,
      WA_IEMBWIPICINFOTP TYPE IEMBWIPICINFOTP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IEMBWIPICINFOTP> TYPE IEMBWIPICINFOTP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IEMBWIPICINFOTP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IEMBWIPICINFOTP
  INTO TABLE IT_IEMBWIPICINFOTP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IEMBWIPICINFOTP
*  INTO TABLE @DATA(IT_IEMBWIPICINFOTP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IEMBWIPICINFOTP INDEX 1 INTO DATA(WA_IEMBWIPICINFOTP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IEMBWIPICINFOTP ASSIGNING <IEMBWIPICINFOTP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IEMBWIPICINFOTP>-MANDT = 1.
<IEMBWIPICINFOTP>-MFGWORKINSTRUCTION = 1.
<IEMBWIPICINFOTP>-MFGWORKINSTRUCTIONVERSCOUNTER = 1.
<IEMBWIPICINFOTP>-MFGWORKINSTRUCTIONVARIABLE = 1.
<IEMBWIPICINFOTP>-PRODNRTGVERSBOMINTERNALID = 1.
ENDLOOP.

LOOP AT IT_IEMBWIPICINFOTP INTO WA_IEMBWIPICINFOTP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IEMBWIPICINFOTP-SELECTEDCONTEXTTYPE, sy-vline,
WA_IEMBWIPICINFOTP-INSPECTIONCHARACTERISTICNMBR, sy-vline,
WA_IEMBWIPICINFOTP-BOOCHARCGROUP, sy-vline,
WA_IEMBWIPICINFOTP-INSPSPECLOWERLIMIT, sy-vline,
WA_IEMBWIPICINFOTP-INSPECTIONSPECIFICATIONUNIT, sy-vline,
WA_IEMBWIPICINFOTP-INSPECTIONSPECIFICATION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IEMBWIPICINFOTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IEMBWIPICINFOTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IEMBWIPICINFOTP INTO WA_IEMBWIPICINFOTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field INSPECTIONSPECIFICATIONUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IEMBWIPICINFOTP-INSPECTIONSPECIFICATIONUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEMBWIPICINFOTP-INSPECTIONSPECIFICATIONUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONSPECIFICATION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEMBWIPICINFOTP-INSPECTIONSPECIFICATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEMBWIPICINFOTP-INSPECTIONSPECIFICATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field BILLOFMATERIALCOMPONENT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IEMBWIPICINFOTP-BILLOFMATERIALCOMPONENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEMBWIPICINFOTP-BILLOFMATERIALCOMPONENT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IEMBWIPICINFOTP_STR,
MANDT TYPE STRING,
MFGWORKINSTRUCTION TYPE STRING,
MFGWORKINSTRUCTIONVERSCOUNTER TYPE STRING,
MFGWORKINSTRUCTIONVARIABLE TYPE STRING,
PRODNRTGVERSBOMINTERNALID TYPE STRING,
SELECTEDCONTEXTTYPE TYPE STRING,
INSPECTIONCHARACTERISTICNMBR TYPE STRING,
BOOCHARCGROUP TYPE STRING,
INSPSPECLOWERLIMIT TYPE STRING,
INSPECTIONSPECIFICATIONUNIT TYPE STRING,
INSPECTIONSPECIFICATION TYPE STRING,
INSPECTIONCHARACTERISTICTEXT TYPE STRING,
INSPSPECTARGETVALUE TYPE STRING,
INSPSPECUPPERLIMIT TYPE STRING,
SELECTEDCODESET TYPE STRING,
INSPSPECISQUANTITATIVE TYPE STRING,
INSPCHARCGRPDESC TYPE STRING,
BOOCHARCGROUPDIVISION TYPE STRING,
INSPCHARCGRPDIVNDESC TYPE STRING,
BOOCHARCSOURCECHARC TYPE STRING,
OPACTYCHARACTERISTICITEM TYPE STRING,
OPACTYCHARCGRPSQNC TYPE STRING,
OPACTYCHARCDIVNSQNC TYPE STRING,
CREATEDBYUSER TYPE STRING,
CREATIONDATETIME TYPE STRING,
CHANGEDBY TYPE STRING,
LASTCHANGEDATETIME TYPE STRING,
MFGISITEMSELECTED TYPE STRING,
UNITOFMEASURETECHNICALNAME TYPE STRING,
BILLOFMATERIALCOMPONENT TYPE STRING,
BILLOFMATERIALCOMPONENTNAME TYPE STRING,
BOOOPBOMITEMINTERNALID TYPE STRING,
ORIGLDGTLMOCKUPCHARCSUUID TYPE STRING,
REFERENCEDESIGNATORVALUE TYPE STRING,END OF T_EKKO_STR. DATA: WA_IEMBWIPICINFOTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IEMBWIPICINFOTP_STR-MANDT sy-vline
WA_IEMBWIPICINFOTP_STR-MFGWORKINSTRUCTION sy-vline
WA_IEMBWIPICINFOTP_STR-MFGWORKINSTRUCTIONVERSCOUNTER sy-vline
WA_IEMBWIPICINFOTP_STR-MFGWORKINSTRUCTIONVARIABLE sy-vline
WA_IEMBWIPICINFOTP_STR-PRODNRTGVERSBOMINTERNALID sy-vline
WA_IEMBWIPICINFOTP_STR-SELECTEDCONTEXTTYPE sy-vline
WA_IEMBWIPICINFOTP_STR-INSPECTIONCHARACTERISTICNMBR sy-vline
WA_IEMBWIPICINFOTP_STR-BOOCHARCGROUP sy-vline
WA_IEMBWIPICINFOTP_STR-INSPSPECLOWERLIMIT sy-vline
WA_IEMBWIPICINFOTP_STR-INSPECTIONSPECIFICATIONUNIT sy-vline
WA_IEMBWIPICINFOTP_STR-INSPECTIONSPECIFICATION sy-vline
WA_IEMBWIPICINFOTP_STR-INSPECTIONCHARACTERISTICTEXT sy-vline
WA_IEMBWIPICINFOTP_STR-INSPSPECTARGETVALUE sy-vline
WA_IEMBWIPICINFOTP_STR-INSPSPECUPPERLIMIT sy-vline
WA_IEMBWIPICINFOTP_STR-SELECTEDCODESET sy-vline
WA_IEMBWIPICINFOTP_STR-INSPSPECISQUANTITATIVE sy-vline
WA_IEMBWIPICINFOTP_STR-INSPCHARCGRPDESC sy-vline
WA_IEMBWIPICINFOTP_STR-BOOCHARCGROUPDIVISION sy-vline
WA_IEMBWIPICINFOTP_STR-INSPCHARCGRPDIVNDESC sy-vline
WA_IEMBWIPICINFOTP_STR-BOOCHARCSOURCECHARC sy-vline
WA_IEMBWIPICINFOTP_STR-OPACTYCHARACTERISTICITEM sy-vline
WA_IEMBWIPICINFOTP_STR-OPACTYCHARCGRPSQNC sy-vline
WA_IEMBWIPICINFOTP_STR-OPACTYCHARCDIVNSQNC sy-vline
WA_IEMBWIPICINFOTP_STR-CREATEDBYUSER sy-vline
WA_IEMBWIPICINFOTP_STR-CREATIONDATETIME sy-vline
WA_IEMBWIPICINFOTP_STR-CHANGEDBY sy-vline
WA_IEMBWIPICINFOTP_STR-LASTCHANGEDATETIME sy-vline
WA_IEMBWIPICINFOTP_STR-MFGISITEMSELECTED sy-vline
WA_IEMBWIPICINFOTP_STR-UNITOFMEASURETECHNICALNAME sy-vline
WA_IEMBWIPICINFOTP_STR-BILLOFMATERIALCOMPONENT sy-vline
WA_IEMBWIPICINFOTP_STR-BILLOFMATERIALCOMPONENTNAME sy-vline
WA_IEMBWIPICINFOTP_STR-BOOOPBOMITEMINTERNALID sy-vline
WA_IEMBWIPICINFOTP_STR-ORIGLDGTLMOCKUPCHARCSUUID sy-vline
WA_IEMBWIPICINFOTP_STR-REFERENCEDESIGNATORVALUE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.