ABAP Select data from SAP table IEINSTALLEDDVCE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IEINSTALLEDDVCE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IEINSTALLEDDVCE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IEINSTALLEDDVCE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IEINSTALLEDDVCE TYPE STANDARD TABLE OF IEINSTALLEDDVCE,
      WA_IEINSTALLEDDVCE TYPE IEINSTALLEDDVCE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IEINSTALLEDDVCE> TYPE IEINSTALLEDDVCE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IEINSTALLEDDVCE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IEINSTALLEDDVCE
  INTO TABLE IT_IEINSTALLEDDVCE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IEINSTALLEDDVCE
*  INTO TABLE @DATA(IT_IEINSTALLEDDVCE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IEINSTALLEDDVCE INDEX 1 INTO DATA(WA_IEINSTALLEDDVCE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IEINSTALLEDDVCE ASSIGNING <IEINSTALLEDDVCE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IEINSTALLEDDVCE>-MANDT = 1.
<IEINSTALLEDDVCE>-UTILITIESDEVICE = 1.
<IEINSTALLEDDVCE>-UTILSDEVICEVALIDITYENDDATE = 1.
<IEINSTALLEDDVCE>-UTILSDEVICEACTIVITYREASON = 1.
<IEINSTALLEDDVCE>-UTILSDEVICEVALIDITYSTARTDATE = 1.
ENDLOOP.

LOOP AT IT_IEINSTALLEDDVCE INTO WA_IEINSTALLEDDVCE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IEINSTALLEDDVCE-UTILSDEVICEBSCCATCOMBINATION, sy-vline,
WA_IEINSTALLEDDVCE-UTILITIESLOGICALDEVICENUMBER, sy-vline,
WA_IEINSTALLEDDVCE-UTILITIESREGISTERGROUP, sy-vline,
WA_IEINSTALLEDDVCE-UTILSDEVICEINSTALLATIONDATE, sy-vline,
WA_IEINSTALLEDDVCE-UTILSDEVICEREMOVALDATE, sy-vline,
WA_IEINSTALLEDDVCE-UTILSDEVICELOCATION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IEINSTALLEDDVCE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IEINSTALLEDDVCE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IEINSTALLEDDVCE INTO WA_IEINSTALLEDDVCE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field UTILITIESDEVICE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEINSTALLEDDVCE-UTILITIESDEVICE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEINSTALLEDDVCE-UTILITIESDEVICE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UTILITIESREGISTERGROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEINSTALLEDDVCE-UTILITIESREGISTERGROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEINSTALLEDDVCE-UTILITIESREGISTERGROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field UTILSDEVICELOCATION CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_IEINSTALLEDDVCE-UTILSDEVICELOCATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEINSTALLEDDVCE-UTILSDEVICELOCATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UTILSDEVICEGROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEINSTALLEDDVCE-UTILSDEVICEGROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEINSTALLEDDVCE-UTILSDEVICEGROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UTILSDEVICEWINDINGGROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEINSTALLEDDVCE-UTILSDEVICEWINDINGGROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEINSTALLEDDVCE-UTILSDEVICEWINDINGGROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field UTILITIESDEVICECATEGORY CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IEINSTALLEDDVCE-UTILITIESDEVICECATEGORY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEINSTALLEDDVCE-UTILITIESDEVICECATEGORY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SERIALNUMBER CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_IEINSTALLEDDVCE-SERIALNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEINSTALLEDDVCE-SERIALNUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UTILSDEVICEINOUTGROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEINSTALLEDDVCE-UTILSDEVICEINOUTGROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEINSTALLEDDVCE-UTILSDEVICEINOUTGROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UTILSDEVICEARCRCOMMANDGROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEINSTALLEDDVCE-UTILSDEVICEARCRCOMMANDGROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEINSTALLEDDVCE-UTILSDEVICEARCRCOMMANDGROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UTILSDEVICESAMPLELOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEINSTALLEDDVCE-UTILSDEVICESAMPLELOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEINSTALLEDDVCE-UTILSDEVICESAMPLELOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UTILSDEVICEINSPPOINTGROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEINSTALLEDDVCE-UTILSDEVICEINSPPOINTGROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEINSTALLEDDVCE-UTILSDEVICEINSPPOINTGROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UTILSDEVICECATEGORYPRICECLASS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEINSTALLEDDVCE-UTILSDEVICECATEGORYPRICECLASS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEINSTALLEDDVCE-UTILSDEVICECATEGORYPRICECLASS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field FUNCTIONALLOCATION CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_IEINSTALLEDDVCE-FUNCTIONALLOCATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEINSTALLEDDVCE-FUNCTIONALLOCATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADDRESSID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEINSTALLEDDVCE-ADDRESSID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEINSTALLEDDVCE-ADDRESSID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CITYCODE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEINSTALLEDDVCE-CITYCODE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEINSTALLEDDVCE-CITYCODE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COUNTYCODE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEINSTALLEDDVCE-COUNTYCODE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEINSTALLEDDVCE-COUNTYCODE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COSTCENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEINSTALLEDDVCE-COSTCENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEINSTALLEDDVCE-COSTCENTER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IEINSTALLEDDVCE_STR,
MANDT TYPE STRING,
UTILITIESDEVICE TYPE STRING,
UTILSDEVICEVALIDITYENDDATE TYPE STRING,
UTILSDEVICEACTIVITYREASON TYPE STRING,
UTILSDEVICEVALIDITYSTARTDATE TYPE STRING,
UTILSDEVICEBSCCATCOMBINATION TYPE STRING,
UTILITIESLOGICALDEVICENUMBER TYPE STRING,
UTILITIESREGISTERGROUP TYPE STRING,
UTILSDEVICEINSTALLATIONDATE TYPE STRING,
UTILSDEVICEREMOVALDATE TYPE STRING,
UTILSDEVICELOCATION TYPE STRING,
UTILSDEVICEGROUP TYPE STRING,
UTILSDEVICEWINDINGGROUP TYPE STRING,
UTILITIESPREPAYMENTMETERTYPE TYPE STRING,
UTILSDEVICELOSSDETNGROUP TYPE STRING,
DVCEPWRTRNSFRMTRTRNSFRATINGVAL TYPE STRING,
DVCEPWRTRNSFRMTRPRIMVOLTVAL TYPE STRING,
DVCEPWRTRNSFRMTRSECDRYVOLTVAL TYPE STRING,
ADVANCEDMETERINGSYSTEM TYPE STRING,
ADVANCEDMETERCAPABILITYGROUP TYPE STRING,
EQUIPMENTCATEGORY TYPE STRING,
TECHNICALOBJECTTYPE TYPE STRING,
AUTHORIZATIONGROUP TYPE STRING,
ACQUISITIONDATE TYPE STRING,
ACQUISITIONVALUE TYPE STRING,
CURRENCY TYPE STRING,
ASSETMANUFACTURERNAME TYPE STRING,
MANUFACTURERCOUNTRY TYPE STRING,
MANUFACTURERSERIALNUMBER TYPE STRING,
MANUFACTURERPARTTYPENAME TYPE STRING,
CONSTRUCTIONYEAR TYPE STRING,
UTILITIESDEVICECATEGORY TYPE STRING,
SERIALNUMBER TYPE STRING,
PLANT TYPE STRING,
DIVISION TYPE STRING,
STORAGELOCATION TYPE STRING,
UNIQUEITEMIDENTIFIER TYPE STRING,
UNIQUEITEMIDENTIFIERSTRUCTYPE TYPE STRING,
UNIQUEITEMIDENTIFIERRESPPLANT TYPE STRING,
UTILSDEVICEINOUTGROUP TYPE STRING,
UTILSDEVICEARCRCOMMANDGROUP TYPE STRING,
UTILSDEVICESAMPLELOT TYPE STRING,
UTILSDEVICEMEASUREDPRESSURE TYPE STRING,
UTILSDEVICETRANSFORMATIONRATIO TYPE STRING,
UTILSDEVICEINSPRELEVANCECODE TYPE STRING,
UTILSDEVICECERTIFICATIONYEAR TYPE STRING,
UTILSDEVICEADVNCRPLCMTYEAR TYPE STRING,
UTILSDEVICECERTFNSTATUS TYPE STRING,
SAMPLEUTILSDEVICESTATUS TYPE STRING,
UTILSDEVICELASTLEADSEALINGDATE TYPE STRING,
UTILSDEVICECERTFNTYPE TYPE STRING,
UTILSDEVICECERTIFICATIONNUMBER TYPE STRING,
UTILSDEVICEMODIFICATIONDATE TYPE STRING,
UTILSDEVICEMODREASON TYPE STRING,
UTILSDEVICECALIBRNVALDTYISUSED TYPE STRING,
UTILSDEVICEPARAMETRIZATIONCODE TYPE STRING,
UTILSDEVICELEADSEALINGCODE TYPE STRING,
LASTCHANGEDATE TYPE STRING,
UTILSDEVICELASTCHANGEDBYUSER TYPE STRING,
UTILSDEVICEINSPPOINTGROUP TYPE STRING,
INSTDUTILSDEVICEISCERTIFIABLE TYPE STRING,
UTILSDEVICEINSPECTIONNUMBER TYPE STRING,
DVCEINDIVCERTFNVALDTYINYRS TYPE STRING,
NMBROFINSTALLEDUTILSDEVICES TYPE STRING,
NMBROFINSTALLEDADVANCEDMETERS TYPE STRING,
UTILSDEVICEFUNCTIONCLASS TYPE STRING,
UTILSDEVICECONSTRUCTIONCLASS TYPE STRING,
UTILSDEVICECATEGORYDESCRIPTION TYPE STRING,
UTILSDEVICECATEGORYPRICECLASS TYPE STRING,
UTILSDEVICEPTIREGNNMBR TYPE STRING,
UTILSDEVICEGGWAREGNNMBR TYPE STRING,
UTILSDEVICECERTFNRQMTTYPE TYPE STRING,
UTILSDVCECALIBRNVALDTYLNYEARS TYPE STRING,
UTILSDVCEINTCERTFNPERDINYEARS TYPE STRING,
UTILSDVCECALCNEXTRPLCMTINYEARS TYPE STRING,
UTILSDEVICEOLDCERTFNINYEARS TYPE STRING,
UTILSDEVICEMEASUREMENTTYPE TYPE STRING,
UTILSDEVICENOMINALLOADVALUE TYPE STRING,
UTILSDEVICEADVNCDMETERCAT TYPE STRING,
FUNCTIONALLOCATION TYPE STRING,
MAINTENANCEPLANT TYPE STRING,
MAINTENANCEOBJECTLOCATION TYPE STRING,
ADDRESSID TYPE STRING,
COUNTRY TYPE STRING,
CITYCODE TYPE STRING,
REGION TYPE STRING,
CITYNAME TYPE STRING,
DISTRICT TYPE STRING,
POSTALCODE TYPE STRING,
HOMECITYNAME TYPE STRING,
STREETNAME TYPE STRING,
HOUSENUMBER TYPE STRING,
HOUSENUMBERSUPPLEMENTTEXT TYPE STRING,
COUNTYCODE TYPE STRING,
MAINTOBJECTLOCACCTASSGMTNMBR TYPE STRING,
MAINTENANCEPLANNINGPLANT TYPE STRING,
MAINTENANCEPLANNERGROUP TYPE STRING,
ASSETLOCATION TYPE STRING,
CONTROLLINGAREA TYPE STRING,
COSTCENTER TYPE STRING,END OF T_EKKO_STR. DATA: WA_IEINSTALLEDDVCE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IEINSTALLEDDVCE_STR-MANDT sy-vline
WA_IEINSTALLEDDVCE_STR-UTILITIESDEVICE sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEVALIDITYENDDATE sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEACTIVITYREASON sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEVALIDITYSTARTDATE sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEBSCCATCOMBINATION sy-vline
WA_IEINSTALLEDDVCE_STR-UTILITIESLOGICALDEVICENUMBER sy-vline
WA_IEINSTALLEDDVCE_STR-UTILITIESREGISTERGROUP sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEINSTALLATIONDATE sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEREMOVALDATE sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICELOCATION sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEGROUP sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEWINDINGGROUP sy-vline
WA_IEINSTALLEDDVCE_STR-UTILITIESPREPAYMENTMETERTYPE sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICELOSSDETNGROUP sy-vline
WA_IEINSTALLEDDVCE_STR-DVCEPWRTRNSFRMTRTRNSFRATINGVAL sy-vline
WA_IEINSTALLEDDVCE_STR-DVCEPWRTRNSFRMTRPRIMVOLTVAL sy-vline
WA_IEINSTALLEDDVCE_STR-DVCEPWRTRNSFRMTRSECDRYVOLTVAL sy-vline
WA_IEINSTALLEDDVCE_STR-ADVANCEDMETERINGSYSTEM sy-vline
WA_IEINSTALLEDDVCE_STR-ADVANCEDMETERCAPABILITYGROUP sy-vline
WA_IEINSTALLEDDVCE_STR-EQUIPMENTCATEGORY sy-vline
WA_IEINSTALLEDDVCE_STR-TECHNICALOBJECTTYPE sy-vline
WA_IEINSTALLEDDVCE_STR-AUTHORIZATIONGROUP sy-vline
WA_IEINSTALLEDDVCE_STR-ACQUISITIONDATE sy-vline
WA_IEINSTALLEDDVCE_STR-ACQUISITIONVALUE sy-vline
WA_IEINSTALLEDDVCE_STR-CURRENCY sy-vline
WA_IEINSTALLEDDVCE_STR-ASSETMANUFACTURERNAME sy-vline
WA_IEINSTALLEDDVCE_STR-MANUFACTURERCOUNTRY sy-vline
WA_IEINSTALLEDDVCE_STR-MANUFACTURERSERIALNUMBER sy-vline
WA_IEINSTALLEDDVCE_STR-MANUFACTURERPARTTYPENAME sy-vline
WA_IEINSTALLEDDVCE_STR-CONSTRUCTIONYEAR sy-vline
WA_IEINSTALLEDDVCE_STR-UTILITIESDEVICECATEGORY sy-vline
WA_IEINSTALLEDDVCE_STR-SERIALNUMBER sy-vline
WA_IEINSTALLEDDVCE_STR-PLANT sy-vline
WA_IEINSTALLEDDVCE_STR-DIVISION sy-vline
WA_IEINSTALLEDDVCE_STR-STORAGELOCATION sy-vline
WA_IEINSTALLEDDVCE_STR-UNIQUEITEMIDENTIFIER sy-vline
WA_IEINSTALLEDDVCE_STR-UNIQUEITEMIDENTIFIERSTRUCTYPE sy-vline
WA_IEINSTALLEDDVCE_STR-UNIQUEITEMIDENTIFIERRESPPLANT sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEINOUTGROUP sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEARCRCOMMANDGROUP sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICESAMPLELOT sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEMEASUREDPRESSURE sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICETRANSFORMATIONRATIO sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEINSPRELEVANCECODE sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICECERTIFICATIONYEAR sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEADVNCRPLCMTYEAR sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICECERTFNSTATUS sy-vline
WA_IEINSTALLEDDVCE_STR-SAMPLEUTILSDEVICESTATUS sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICELASTLEADSEALINGDATE sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICECERTFNTYPE sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICECERTIFICATIONNUMBER sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEMODIFICATIONDATE sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEMODREASON sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICECALIBRNVALDTYISUSED sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEPARAMETRIZATIONCODE sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICELEADSEALINGCODE sy-vline
WA_IEINSTALLEDDVCE_STR-LASTCHANGEDATE sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICELASTCHANGEDBYUSER sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEINSPPOINTGROUP sy-vline
WA_IEINSTALLEDDVCE_STR-INSTDUTILSDEVICEISCERTIFIABLE sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEINSPECTIONNUMBER sy-vline
WA_IEINSTALLEDDVCE_STR-DVCEINDIVCERTFNVALDTYINYRS sy-vline
WA_IEINSTALLEDDVCE_STR-NMBROFINSTALLEDUTILSDEVICES sy-vline
WA_IEINSTALLEDDVCE_STR-NMBROFINSTALLEDADVANCEDMETERS sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEFUNCTIONCLASS sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICECONSTRUCTIONCLASS sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICECATEGORYDESCRIPTION sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICECATEGORYPRICECLASS sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEPTIREGNNMBR sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEGGWAREGNNMBR sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICECERTFNRQMTTYPE sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDVCECALIBRNVALDTYLNYEARS sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDVCEINTCERTFNPERDINYEARS sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDVCECALCNEXTRPLCMTINYEARS sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEOLDCERTFNINYEARS sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEMEASUREMENTTYPE sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICENOMINALLOADVALUE sy-vline
WA_IEINSTALLEDDVCE_STR-UTILSDEVICEADVNCDMETERCAT sy-vline
WA_IEINSTALLEDDVCE_STR-FUNCTIONALLOCATION sy-vline
WA_IEINSTALLEDDVCE_STR-MAINTENANCEPLANT sy-vline
WA_IEINSTALLEDDVCE_STR-MAINTENANCEOBJECTLOCATION sy-vline
WA_IEINSTALLEDDVCE_STR-ADDRESSID sy-vline
WA_IEINSTALLEDDVCE_STR-COUNTRY sy-vline
WA_IEINSTALLEDDVCE_STR-CITYCODE sy-vline
WA_IEINSTALLEDDVCE_STR-REGION sy-vline
WA_IEINSTALLEDDVCE_STR-CITYNAME sy-vline
WA_IEINSTALLEDDVCE_STR-DISTRICT sy-vline
WA_IEINSTALLEDDVCE_STR-POSTALCODE sy-vline
WA_IEINSTALLEDDVCE_STR-HOMECITYNAME sy-vline
WA_IEINSTALLEDDVCE_STR-STREETNAME sy-vline
WA_IEINSTALLEDDVCE_STR-HOUSENUMBER sy-vline
WA_IEINSTALLEDDVCE_STR-HOUSENUMBERSUPPLEMENTTEXT sy-vline
WA_IEINSTALLEDDVCE_STR-COUNTYCODE sy-vline
WA_IEINSTALLEDDVCE_STR-MAINTOBJECTLOCACCTASSGMTNMBR sy-vline
WA_IEINSTALLEDDVCE_STR-MAINTENANCEPLANNINGPLANT sy-vline
WA_IEINSTALLEDDVCE_STR-MAINTENANCEPLANNERGROUP sy-vline
WA_IEINSTALLEDDVCE_STR-ASSETLOCATION sy-vline
WA_IEINSTALLEDDVCE_STR-CONTROLLINGAREA sy-vline
WA_IEINSTALLEDDVCE_STR-COSTCENTER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.