ABAP Select data from SAP table IEHSSRCRECTP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IEHSSRCRECTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IEHSSRCRECTP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IEHSSRCRECTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IEHSSRCRECTP TYPE STANDARD TABLE OF IEHSSRCRECTP,
      WA_IEHSSRCRECTP TYPE IEHSSRCRECTP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IEHSSRCRECTP> TYPE IEHSSRCRECTP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IEHSSRCRECTP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IEHSSRCRECTP
  INTO TABLE IT_IEHSSRCRECTP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IEHSSRCRECTP
*  INTO TABLE @DATA(IT_IEHSSRCRECTP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IEHSSRCRECTP INDEX 1 INTO DATA(WA_IEHSSRCRECTP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IEHSSRCRECTP ASSIGNING <IEHSSRCRECTP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IEHSSRCRECTP>-MANDT = 1.
<IEHSSRCRECTP>-SAFETYRELEVANTCHANGERECORDUUID = 1.
<IEHSSRCRECTP>-SAFETYRELEVANTCHANGESOURCETYPE = 1.
<IEHSSRCRECTP>-CHEMICALUUID = 1.
<IEHSSRCRECTP>-SFTYRELEVANTCHANGEUTCDATETIME = 1.
ENDLOOP.

LOOP AT IT_IEHSSRCRECTP INTO WA_IEHSSRCRECTP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IEHSSRCRECTP-CHANGEDOCOBJECTCLASS, sy-vline,
WA_IEHSSRCRECTP-CHANGEDOCOBJECT, sy-vline,
WA_IEHSSRCRECTP-CHANGEDOCUMENT, sy-vline,
WA_IEHSSRCRECTP-CREATIONUTCDATETIME, sy-vline,
WA_IEHSSRCRECTP-CREATEDBYUSER, sy-vline,
WA_IEHSSRCRECTP-LASTCHANGEUTCDATETIME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IEHSSRCRECTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IEHSSRCRECTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IEHSSRCRECTP INTO WA_IEHSSRCRECTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SAFETYRELEVANTCHANGESOURCETYPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEHSSRCRECTP-SAFETYRELEVANTCHANGESOURCETYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEHSSRCRECTP-SAFETYRELEVANTCHANGESOURCETYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CHANGEDOCOBJECTCLASS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEHSSRCRECTP-CHANGEDOCOBJECTCLASS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEHSSRCRECTP-CHANGEDOCOBJECTCLASS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CHANGEDOCUMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEHSSRCRECTP-CHANGEDOCUMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEHSSRCRECTP-CHANGEDOCUMENT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IEHSSRCRECTP_STR,
MANDT TYPE STRING,
SAFETYRELEVANTCHANGERECORDUUID TYPE STRING,
SAFETYRELEVANTCHANGESOURCETYPE TYPE STRING,
CHEMICALUUID TYPE STRING,
SFTYRELEVANTCHANGEUTCDATETIME TYPE STRING,
CHANGEDOCOBJECTCLASS TYPE STRING,
CHANGEDOCOBJECT TYPE STRING,
CHANGEDOCUMENT TYPE STRING,
CREATIONUTCDATETIME TYPE STRING,
CREATEDBYUSER TYPE STRING,
LASTCHANGEUTCDATETIME TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,END OF T_EKKO_STR. DATA: WA_IEHSSRCRECTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IEHSSRCRECTP_STR-MANDT sy-vline
WA_IEHSSRCRECTP_STR-SAFETYRELEVANTCHANGERECORDUUID sy-vline
WA_IEHSSRCRECTP_STR-SAFETYRELEVANTCHANGESOURCETYPE sy-vline
WA_IEHSSRCRECTP_STR-CHEMICALUUID sy-vline
WA_IEHSSRCRECTP_STR-SFTYRELEVANTCHANGEUTCDATETIME sy-vline
WA_IEHSSRCRECTP_STR-CHANGEDOCOBJECTCLASS sy-vline
WA_IEHSSRCRECTP_STR-CHANGEDOCOBJECT sy-vline
WA_IEHSSRCRECTP_STR-CHANGEDOCUMENT sy-vline
WA_IEHSSRCRECTP_STR-CREATIONUTCDATETIME sy-vline
WA_IEHSSRCRECTP_STR-CREATEDBYUSER sy-vline
WA_IEHSSRCRECTP_STR-LASTCHANGEUTCDATETIME sy-vline
WA_IEHSSRCRECTP_STR-LASTCHANGEDBYUSER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.