ABAP Select data from SAP table IEDVCEPERDCRL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IEDVCEPERDCRL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IEDVCEPERDCRL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IEDVCEPERDCRL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IEDVCEPERDCRL TYPE STANDARD TABLE OF IEDVCEPERDCRL,
      WA_IEDVCEPERDCRL TYPE IEDVCEPERDCRL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IEDVCEPERDCRL> TYPE IEDVCEPERDCRL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IEDVCEPERDCRL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IEDVCEPERDCRL
  INTO TABLE IT_IEDVCEPERDCRL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IEDVCEPERDCRL
*  INTO TABLE @DATA(IT_IEDVCEPERDCRL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IEDVCEPERDCRL INDEX 1 INTO DATA(WA_IEDVCEPERDCRL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IEDVCEPERDCRL ASSIGNING <IEDVCEPERDCRL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IEDVCEPERDCRL>-MANDT = 1.
<IEDVCEPERDCRL>-UTILSEQUIPMENTPERDCRPLCMTLIST = 1.
<IEDVCEPERDCRL>-UTILSPERDCRPLCMTYEAR = 1.
<IEDVCEPERDCRL>-UTILSDEVICEREMOVALDATE = 1.
<IEDVCEPERDCRL>-MAINTENANCEORDER = 1.
ENDLOOP.

LOOP AT IT_IEDVCEPERDCRL INTO WA_IEDVCEPERDCRL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IEDVCEPERDCRL-MAINTENANCENOTIFICATION, sy-vline,
WA_IEDVCEPERDCRL-METERREADINGUNIT, sy-vline,
WA_IEDVCEPERDCRL-MATERIAL, sy-vline,
WA_IEDVCEPERDCRL-UTILITIESDIVISION, sy-vline,
WA_IEDVCEPERDCRL-REGIONALSTRUCTUREGROUPING, sy-vline,
WA_IEDVCEPERDCRL-UTILSPERDCRPLCMTCREATIONDATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IEDVCEPERDCRL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IEDVCEPERDCRL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IEDVCEPERDCRL INTO WA_IEDVCEPERDCRL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field UTILSEQUIPMENTPERDCRPLCMTLIST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-UTILSEQUIPMENTPERDCRPLCMTLIST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-UTILSEQUIPMENTPERDCRPLCMTLIST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MAINTENANCEORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-MAINTENANCEORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-MAINTENANCEORDER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MAINTENANCENOTIFICATION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-MAINTENANCENOTIFICATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-MAINTENANCENOTIFICATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UTILITIESDEVICE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-UTILITIESDEVICE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-UTILITIESDEVICE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UTILITIESREGISTERGROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-UTILITIESREGISTERGROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-UTILITIESREGISTERGROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field UTILSDEVICELOCATION CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-UTILSDEVICELOCATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-UTILSDEVICELOCATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UTILSDEVICEGROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-UTILSDEVICEGROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-UTILSDEVICEGROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UTILSDEVICEWINDINGGROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-UTILSDEVICEWINDINGGROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-UTILSDEVICEWINDINGGROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field UTILITIESDEVICECATEGORY CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-UTILITIESDEVICECATEGORY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-UTILITIESDEVICECATEGORY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SERIALNUMBER CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-SERIALNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-SERIALNUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UTILSDEVICEINOUTGROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-UTILSDEVICEINOUTGROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-UTILSDEVICEINOUTGROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UTILSDEVICEARCRCOMMANDGROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-UTILSDEVICEARCRCOMMANDGROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-UTILSDEVICEARCRCOMMANDGROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UTILSDEVICESAMPLELOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-UTILSDEVICESAMPLELOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-UTILSDEVICESAMPLELOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UTILSDEVICEINSPPOINTGROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-UTILSDEVICEINSPPOINTGROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-UTILSDEVICEINSPPOINTGROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UTILSDEVICECATEGORYPRICECLASS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-UTILSDEVICECATEGORYPRICECLASS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-UTILSDEVICECATEGORYPRICECLASS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field FUNCTIONALLOCATION CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-FUNCTIONALLOCATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-FUNCTIONALLOCATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADDRESSID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-ADDRESSID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-ADDRESSID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CITYCODE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-CITYCODE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-CITYCODE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COUNTYCODE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-COUNTYCODE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-COUNTYCODE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COSTCENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEDVCEPERDCRL-COSTCENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEDVCEPERDCRL-COSTCENTER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IEDVCEPERDCRL_STR,
MANDT TYPE STRING,
UTILSEQUIPMENTPERDCRPLCMTLIST TYPE STRING,
UTILSPERDCRPLCMTYEAR TYPE STRING,
UTILSDEVICEREMOVALDATE TYPE STRING,
MAINTENANCEORDER TYPE STRING,
MAINTENANCENOTIFICATION TYPE STRING,
METERREADINGUNIT TYPE STRING,
MATERIAL TYPE STRING,
UTILITIESDIVISION TYPE STRING,
REGIONALSTRUCTUREGROUPING TYPE STRING,
UTILSPERDCRPLCMTCREATIONDATE TYPE STRING,
UTILSPERDCRPLCMTCREATEDBYUSER TYPE STRING,
UTILSPERDCRPLCMTLASTCHANGEDATE TYPE STRING,
UTILSPERDCRPLCMTLASTCHGDBYUSER TYPE STRING,
UTILSDEVICEVALIDITYENDDATE TYPE STRING,
UTILITIESDEVICE TYPE STRING,
UTILSDEVICEACTIVITYREASON TYPE STRING,
UTILSDEVICEVALIDITYSTARTDATE TYPE STRING,
UTILSDEVICEBSCCATCOMBINATION TYPE STRING,
UTILITIESLOGICALDEVICENUMBER TYPE STRING,
UTILITIESREGISTERGROUP TYPE STRING,
UTILSDEVICEINSTALLATIONDATE TYPE STRING,
UTILSDEVICELOCATION TYPE STRING,
UTILSDEVICEGROUP TYPE STRING,
UTILSDEVICEWINDINGGROUP TYPE STRING,
UTILITIESPREPAYMENTMETERTYPE TYPE STRING,
UTILSDEVICELOSSDETNGROUP TYPE STRING,
DVCEPWRTRNSFRMTRTRNSFRATINGVAL TYPE STRING,
DVCEPWRTRNSFRMTRPRIMVOLTVAL TYPE STRING,
DVCEPWRTRNSFRMTRSECDRYVOLTVAL TYPE STRING,
ADVANCEDMETERINGSYSTEM TYPE STRING,
ADVANCEDMETERCAPABILITYGROUP TYPE STRING,
EQUIPMENTCATEGORY TYPE STRING,
TECHNICALOBJECTTYPE TYPE STRING,
AUTHORIZATIONGROUP TYPE STRING,
ACQUISITIONDATE TYPE STRING,
ACQUISITIONVALUE TYPE STRING,
CURRENCY TYPE STRING,
ASSETMANUFACTURERNAME TYPE STRING,
MANUFACTURERCOUNTRY TYPE STRING,
MANUFACTURERSERIALNUMBER TYPE STRING,
MANUFACTURERPARTTYPENAME TYPE STRING,
CONSTRUCTIONYEAR TYPE STRING,
UTILITIESDEVICECATEGORY TYPE STRING,
SERIALNUMBER TYPE STRING,
PLANT TYPE STRING,
DIVISION TYPE STRING,
STORAGELOCATION TYPE STRING,
UNIQUEITEMIDENTIFIER TYPE STRING,
UNIQUEITEMIDENTIFIERSTRUCTYPE TYPE STRING,
UNIQUEITEMIDENTIFIERRESPPLANT TYPE STRING,
UTILSDEVICEINOUTGROUP TYPE STRING,
UTILSDEVICEARCRCOMMANDGROUP TYPE STRING,
UTILSDEVICESAMPLELOT TYPE STRING,
UTILSDEVICEMEASUREDPRESSURE TYPE STRING,
UTILSDEVICETRANSFORMATIONRATIO TYPE STRING,
UTILSDEVICEINSPRELEVANCECODE TYPE STRING,
UTILSDEVICECERTIFICATIONYEAR TYPE STRING,
UTILSDEVICEADVNCRPLCMTYEAR TYPE STRING,
UTILSDEVICECERTFNSTATUS TYPE STRING,
SAMPLEUTILSDEVICESTATUS TYPE STRING,
UTILSDEVICELASTLEADSEALINGDATE TYPE STRING,
UTILSDEVICECERTFNTYPE TYPE STRING,
UTILSDEVICECERTIFICATIONNUMBER TYPE STRING,
UTILSDEVICEMODIFICATIONDATE TYPE STRING,
UTILSDEVICEMODREASON TYPE STRING,
UTILSDEVICECALIBRNVALDTYISUSED TYPE STRING,
UTILSDEVICEPARAMETRIZATIONCODE TYPE STRING,
UTILSDEVICELEADSEALINGCODE TYPE STRING,
LASTCHANGEDATE TYPE STRING,
UTILSDEVICELASTCHANGEDBYUSER TYPE STRING,
UTILSDEVICEINSPPOINTGROUP TYPE STRING,
INSTDUTILSDEVICEISCERTIFIABLE TYPE STRING,
UTILSDEVICEINSPECTIONNUMBER TYPE STRING,
DVCEINDIVCERTFNVALDTYINYRS TYPE STRING,
UTILSDEVICEFUNCTIONCLASS TYPE STRING,
UTILSDEVICECONSTRUCTIONCLASS TYPE STRING,
UTILSDEVICECATEGORYDESCRIPTION TYPE STRING,
UTILSDEVICECATEGORYPRICECLASS TYPE STRING,
UTILSDEVICEPTIREGNNMBR TYPE STRING,
UTILSDEVICEGGWAREGNNMBR TYPE STRING,
UTILSDEVICECERTFNRQMTTYPE TYPE STRING,
UTILSDVCECALIBRNVALDTYLNYEARS TYPE STRING,
UTILSDVCEINTCERTFNPERDINYEARS TYPE STRING,
UTILSDVCECALCNEXTRPLCMTINYEARS TYPE STRING,
UTILSDEVICEOLDCERTFNINYEARS TYPE STRING,
UTILSDEVICEMEASUREMENTTYPE TYPE STRING,
UTILSDEVICENOMINALLOADVALUE TYPE STRING,
UTILSDEVICEADVNCDMETERCAT TYPE STRING,
FUNCTIONALLOCATION TYPE STRING,
MAINTENANCEPLANT TYPE STRING,
ADDRESSID TYPE STRING,
COUNTRY TYPE STRING,
REGION TYPE STRING,
CITYCODE TYPE STRING,
CITYNAME TYPE STRING,
DISTRICT TYPE STRING,
HOMECITYNAME TYPE STRING,
POSTALCODE TYPE STRING,
STREETNAME TYPE STRING,
HOUSENUMBER TYPE STRING,
HOUSENUMBERSUPPLEMENTTEXT TYPE STRING,
COUNTYCODE TYPE STRING,
MAINTOBJECTLOCACCTASSGMTNMBR TYPE STRING,
MAINTENANCEPLANNINGPLANT TYPE STRING,
MAINTENANCEPLANNERGROUP TYPE STRING,
ASSETLOCATION TYPE STRING,
CONTROLLINGAREA TYPE STRING,
COSTCENTER TYPE STRING,
MAINTENANCEOBJECTLOCATION TYPE STRING,
NMBROFDEVICESTOBEREPLACED TYPE STRING,
NMBROFREMOVEDDEVICES TYPE STRING,END OF T_EKKO_STR. DATA: WA_IEDVCEPERDCRL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IEDVCEPERDCRL_STR-MANDT sy-vline
WA_IEDVCEPERDCRL_STR-UTILSEQUIPMENTPERDCRPLCMTLIST sy-vline
WA_IEDVCEPERDCRL_STR-UTILSPERDCRPLCMTYEAR sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEREMOVALDATE sy-vline
WA_IEDVCEPERDCRL_STR-MAINTENANCEORDER sy-vline
WA_IEDVCEPERDCRL_STR-MAINTENANCENOTIFICATION sy-vline
WA_IEDVCEPERDCRL_STR-METERREADINGUNIT sy-vline
WA_IEDVCEPERDCRL_STR-MATERIAL sy-vline
WA_IEDVCEPERDCRL_STR-UTILITIESDIVISION sy-vline
WA_IEDVCEPERDCRL_STR-REGIONALSTRUCTUREGROUPING sy-vline
WA_IEDVCEPERDCRL_STR-UTILSPERDCRPLCMTCREATIONDATE sy-vline
WA_IEDVCEPERDCRL_STR-UTILSPERDCRPLCMTCREATEDBYUSER sy-vline
WA_IEDVCEPERDCRL_STR-UTILSPERDCRPLCMTLASTCHANGEDATE sy-vline
WA_IEDVCEPERDCRL_STR-UTILSPERDCRPLCMTLASTCHGDBYUSER sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEVALIDITYENDDATE sy-vline
WA_IEDVCEPERDCRL_STR-UTILITIESDEVICE sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEACTIVITYREASON sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEVALIDITYSTARTDATE sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEBSCCATCOMBINATION sy-vline
WA_IEDVCEPERDCRL_STR-UTILITIESLOGICALDEVICENUMBER sy-vline
WA_IEDVCEPERDCRL_STR-UTILITIESREGISTERGROUP sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEINSTALLATIONDATE sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICELOCATION sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEGROUP sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEWINDINGGROUP sy-vline
WA_IEDVCEPERDCRL_STR-UTILITIESPREPAYMENTMETERTYPE sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICELOSSDETNGROUP sy-vline
WA_IEDVCEPERDCRL_STR-DVCEPWRTRNSFRMTRTRNSFRATINGVAL sy-vline
WA_IEDVCEPERDCRL_STR-DVCEPWRTRNSFRMTRPRIMVOLTVAL sy-vline
WA_IEDVCEPERDCRL_STR-DVCEPWRTRNSFRMTRSECDRYVOLTVAL sy-vline
WA_IEDVCEPERDCRL_STR-ADVANCEDMETERINGSYSTEM sy-vline
WA_IEDVCEPERDCRL_STR-ADVANCEDMETERCAPABILITYGROUP sy-vline
WA_IEDVCEPERDCRL_STR-EQUIPMENTCATEGORY sy-vline
WA_IEDVCEPERDCRL_STR-TECHNICALOBJECTTYPE sy-vline
WA_IEDVCEPERDCRL_STR-AUTHORIZATIONGROUP sy-vline
WA_IEDVCEPERDCRL_STR-ACQUISITIONDATE sy-vline
WA_IEDVCEPERDCRL_STR-ACQUISITIONVALUE sy-vline
WA_IEDVCEPERDCRL_STR-CURRENCY sy-vline
WA_IEDVCEPERDCRL_STR-ASSETMANUFACTURERNAME sy-vline
WA_IEDVCEPERDCRL_STR-MANUFACTURERCOUNTRY sy-vline
WA_IEDVCEPERDCRL_STR-MANUFACTURERSERIALNUMBER sy-vline
WA_IEDVCEPERDCRL_STR-MANUFACTURERPARTTYPENAME sy-vline
WA_IEDVCEPERDCRL_STR-CONSTRUCTIONYEAR sy-vline
WA_IEDVCEPERDCRL_STR-UTILITIESDEVICECATEGORY sy-vline
WA_IEDVCEPERDCRL_STR-SERIALNUMBER sy-vline
WA_IEDVCEPERDCRL_STR-PLANT sy-vline
WA_IEDVCEPERDCRL_STR-DIVISION sy-vline
WA_IEDVCEPERDCRL_STR-STORAGELOCATION sy-vline
WA_IEDVCEPERDCRL_STR-UNIQUEITEMIDENTIFIER sy-vline
WA_IEDVCEPERDCRL_STR-UNIQUEITEMIDENTIFIERSTRUCTYPE sy-vline
WA_IEDVCEPERDCRL_STR-UNIQUEITEMIDENTIFIERRESPPLANT sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEINOUTGROUP sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEARCRCOMMANDGROUP sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICESAMPLELOT sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEMEASUREDPRESSURE sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICETRANSFORMATIONRATIO sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEINSPRELEVANCECODE sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICECERTIFICATIONYEAR sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEADVNCRPLCMTYEAR sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICECERTFNSTATUS sy-vline
WA_IEDVCEPERDCRL_STR-SAMPLEUTILSDEVICESTATUS sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICELASTLEADSEALINGDATE sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICECERTFNTYPE sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICECERTIFICATIONNUMBER sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEMODIFICATIONDATE sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEMODREASON sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICECALIBRNVALDTYISUSED sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEPARAMETRIZATIONCODE sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICELEADSEALINGCODE sy-vline
WA_IEDVCEPERDCRL_STR-LASTCHANGEDATE sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICELASTCHANGEDBYUSER sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEINSPPOINTGROUP sy-vline
WA_IEDVCEPERDCRL_STR-INSTDUTILSDEVICEISCERTIFIABLE sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEINSPECTIONNUMBER sy-vline
WA_IEDVCEPERDCRL_STR-DVCEINDIVCERTFNVALDTYINYRS sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEFUNCTIONCLASS sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICECONSTRUCTIONCLASS sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICECATEGORYDESCRIPTION sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICECATEGORYPRICECLASS sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEPTIREGNNMBR sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEGGWAREGNNMBR sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICECERTFNRQMTTYPE sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDVCECALIBRNVALDTYLNYEARS sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDVCEINTCERTFNPERDINYEARS sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDVCECALCNEXTRPLCMTINYEARS sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEOLDCERTFNINYEARS sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEMEASUREMENTTYPE sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICENOMINALLOADVALUE sy-vline
WA_IEDVCEPERDCRL_STR-UTILSDEVICEADVNCDMETERCAT sy-vline
WA_IEDVCEPERDCRL_STR-FUNCTIONALLOCATION sy-vline
WA_IEDVCEPERDCRL_STR-MAINTENANCEPLANT sy-vline
WA_IEDVCEPERDCRL_STR-ADDRESSID sy-vline
WA_IEDVCEPERDCRL_STR-COUNTRY sy-vline
WA_IEDVCEPERDCRL_STR-REGION sy-vline
WA_IEDVCEPERDCRL_STR-CITYCODE sy-vline
WA_IEDVCEPERDCRL_STR-CITYNAME sy-vline
WA_IEDVCEPERDCRL_STR-DISTRICT sy-vline
WA_IEDVCEPERDCRL_STR-HOMECITYNAME sy-vline
WA_IEDVCEPERDCRL_STR-POSTALCODE sy-vline
WA_IEDVCEPERDCRL_STR-STREETNAME sy-vline
WA_IEDVCEPERDCRL_STR-HOUSENUMBER sy-vline
WA_IEDVCEPERDCRL_STR-HOUSENUMBERSUPPLEMENTTEXT sy-vline
WA_IEDVCEPERDCRL_STR-COUNTYCODE sy-vline
WA_IEDVCEPERDCRL_STR-MAINTOBJECTLOCACCTASSGMTNMBR sy-vline
WA_IEDVCEPERDCRL_STR-MAINTENANCEPLANNINGPLANT sy-vline
WA_IEDVCEPERDCRL_STR-MAINTENANCEPLANNERGROUP sy-vline
WA_IEDVCEPERDCRL_STR-ASSETLOCATION sy-vline
WA_IEDVCEPERDCRL_STR-CONTROLLINGAREA sy-vline
WA_IEDVCEPERDCRL_STR-COSTCENTER sy-vline
WA_IEDVCEPERDCRL_STR-MAINTENANCEOBJECTLOCATION sy-vline
WA_IEDVCEPERDCRL_STR-NMBROFDEVICESTOBEREPLACED sy-vline
WA_IEDVCEPERDCRL_STR-NMBROFREMOVEDDEVICES sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.