ABAP Select data from SAP table IECNOMRMBOM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IECNOMRMBOM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IECNOMRMBOM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IECNOMRMBOM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IECNOMRMBOM TYPE STANDARD TABLE OF IECNOMRMBOM,
      WA_IECNOMRMBOM TYPE IECNOMRMBOM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IECNOMRMBOM> TYPE IECNOMRMBOM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IECNOMRMBOM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IECNOMRMBOM
  INTO TABLE IT_IECNOMRMBOM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IECNOMRMBOM
*  INTO TABLE @DATA(IT_IECNOMRMBOM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IECNOMRMBOM INDEX 1 INTO DATA(WA_IECNOMRMBOM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IECNOMRMBOM ASSIGNING <IECNOMRMBOM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IECNOMRMBOM>-MANDT = 1.
<IECNOMRMBOM>-CHANGENUMBER = 1.
<IECNOMRMBOM>-MATERIAL = 1.
<IECNOMRMBOM>-PLANT = 1.
<IECNOMRMBOM>-BILLOFMATERIALVARIANTUSAGE = 1.
ENDLOOP.

LOOP AT IT_IECNOMRMBOM INTO WA_IECNOMRMBOM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IECNOMRMBOM-OBJMGMTRECDOBJECT, sy-vline,
WA_IECNOMRMBOM-OBJMGMTRECDOBJECTINTERNALID, sy-vline,
WA_IECNOMRMBOM-CHGNMBRALTERNATIVEDATECOUNTER, sy-vline,
WA_IECNOMRMBOM-OBJMGMTRECDDESCRIPTION, sy-vline,
WA_IECNOMRMBOM-OBJMGMTRECDITEMUUID, sy-vline,
WA_IECNOMRMBOM-OBJMGMTRECDLASTCHANGEDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IECNOMRMBOM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IECNOMRMBOM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IECNOMRMBOM INTO WA_IECNOMRMBOM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CHANGENUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IECNOMRMBOM-CHANGENUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IECNOMRMBOM-CHANGENUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IECNOMRMBOM-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IECNOMRMBOM-MATERIAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IECNOMRMBOM_STR,
MANDT TYPE STRING,
CHANGENUMBER TYPE STRING,
MATERIAL TYPE STRING,
PLANT TYPE STRING,
BILLOFMATERIALVARIANTUSAGE TYPE STRING,
OBJMGMTRECDOBJECT TYPE STRING,
OBJMGMTRECDOBJECTINTERNALID TYPE STRING,
CHGNMBRALTERNATIVEDATECOUNTER TYPE STRING,
OBJMGMTRECDDESCRIPTION TYPE STRING,
OBJMGMTRECDITEMUUID TYPE STRING,
OBJMGMTRECDLASTCHANGEDAT TYPE STRING,
OBJMGMTRECDLASTCHANGEDBY TYPE STRING,
OBJMGMTRECDCREATIONDATE TYPE STRING,
OBJMGMTRECDCREATEDBY TYPE STRING,
OBJMGMTRECDOBJLASTCHANGEDAT TYPE STRING,
OBJMGMTRECDOBJLASTCHANGEDBY TYPE STRING,
OBJMGMTRECDOBJISLOCKEDFORCHG TYPE STRING,
OBJMGMTRECDOBJISBASELINED TYPE STRING,
OBJMGMTRECDCHANGETYPE TYPE STRING,
OBJMGMTRECDOBJISPLANNED TYPE STRING,
OBJMGMTRECDOBJREVISIONLEVEL TYPE STRING,END OF T_EKKO_STR. DATA: WA_IECNOMRMBOM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IECNOMRMBOM_STR-MANDT sy-vline
WA_IECNOMRMBOM_STR-CHANGENUMBER sy-vline
WA_IECNOMRMBOM_STR-MATERIAL sy-vline
WA_IECNOMRMBOM_STR-PLANT sy-vline
WA_IECNOMRMBOM_STR-BILLOFMATERIALVARIANTUSAGE sy-vline
WA_IECNOMRMBOM_STR-OBJMGMTRECDOBJECT sy-vline
WA_IECNOMRMBOM_STR-OBJMGMTRECDOBJECTINTERNALID sy-vline
WA_IECNOMRMBOM_STR-CHGNMBRALTERNATIVEDATECOUNTER sy-vline
WA_IECNOMRMBOM_STR-OBJMGMTRECDDESCRIPTION sy-vline
WA_IECNOMRMBOM_STR-OBJMGMTRECDITEMUUID sy-vline
WA_IECNOMRMBOM_STR-OBJMGMTRECDLASTCHANGEDAT sy-vline
WA_IECNOMRMBOM_STR-OBJMGMTRECDLASTCHANGEDBY sy-vline
WA_IECNOMRMBOM_STR-OBJMGMTRECDCREATIONDATE sy-vline
WA_IECNOMRMBOM_STR-OBJMGMTRECDCREATEDBY sy-vline
WA_IECNOMRMBOM_STR-OBJMGMTRECDOBJLASTCHANGEDAT sy-vline
WA_IECNOMRMBOM_STR-OBJMGMTRECDOBJLASTCHANGEDBY sy-vline
WA_IECNOMRMBOM_STR-OBJMGMTRECDOBJISLOCKEDFORCHG sy-vline
WA_IECNOMRMBOM_STR-OBJMGMTRECDOBJISBASELINED sy-vline
WA_IECNOMRMBOM_STR-OBJMGMTRECDCHANGETYPE sy-vline
WA_IECNOMRMBOM_STR-OBJMGMTRECDOBJISPLANNED sy-vline
WA_IECNOMRMBOM_STR-OBJMGMTRECDOBJREVISIONLEVEL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.